Parameters
List of parameters
r0586
CO: Measuring probe, velocity actual value / MT v_act
SERVO (Lin)
Can be changed: -
Data type: Floating Point
P-Group: Displays, signals
Not for motor type: -
Min
- [m/min]
Description:
Displays the velocity actual value measured using the BERO.
Dependency:
Refer to: p0580, p0583
Note:
For p0580 = 0 (no measuring probe), a value of zero is displayed here.
r0587
CO: Measuring probe, measuring time measured / MT t_meas measured
SERVO
Can be changed: -
Data type: Unsigned32
P-Group: Displays, signals
Not for motor type: -
Min
-
Description:
Displays the time between the last two BERO pulses.
The measuring time is specified as 32-bit value with a resolution of 1/48 µs.
If a new pulse is not received before the maximum measured time in p0583 expires, then r0587 is set to the maxi-
mum measuring time.
Dependency:
Refer to: p0580
Note:
For p0580 = 0 (no measuring probe), a value of zero is displayed here.
r0588
CO: Measuring probe, pulse counter / MT pulse counter
SERVO
Can be changed: -
Data type: Unsigned32
P-Group: Displays, signals
Not for motor type: -
Min
-
Description:
Displays the number of measuring pulses that have occurred (been received) up until now.
Dependency:
Refer to: p0580
Note:
After reaching 4294967295 (2^32 - 1), the counter starts again at 0.
r0589
Measuring probe, delay time / MT t_delay
SERVO
Can be changed: -
Data type: Unsigned32
P-Group: Displays, signals
Not for motor type: -
Min
-
Description:
Displays the time since the last measuring pulse was detected.
The delay time is specified as 32-bit value with a resolution of 1/48 µs.
When a measuring pulse occurs (is received) the delay time is reset and is limited to the maximum measuring time
in p0583.
Dependency:
Refer to: p0580
Note:
For p0580 = 0 (no measuring probe), a value of zero is displayed here.
1-206
Calculated: -
Dynamic index: -
Units group: 4_1
Max
- [m/min]
Calculated: -
Dynamic index: -
Units group: -
Max
-
Calculated: -
Dynamic index: -
Units group: -
Max
-
Calculated: -
Dynamic index: -
Units group: -
Max
-
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Access level: 3
Func. diagram: -
Unit selection: p0505
Expert list: 1
Factory setting
- [m/min]
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-