Table 6.5 Message Type to Configure a MSG to Logix5000 Controller
If You Want To
write (send) the data
Table 6.6 Message Type to Configure a MSG to an SLC 500 Processor
If The Data Is
And You Want To
integer (s)
read (receive) data
write (send) data
floating-point (REAL)
read (receive) data
write (send) data
For This Item
Message Type
Source Tag
Number of Elements
Destination Element
Message Type to Configure a MSG to an SLC 500 Processor
For This Item
Message Type
Source Element
Number of Elements
Destination Tag
Message Type
Source Tag
Number of Elements
Destination Element
Message Type
Source Element
Number Of Elements
Destination Tag
Message Type
Source Tag
Number Of Elements
Destination Element
Type or Select
CIP Data Table Write
first element of the tag (controller-scoped) in this controller that
contains the data
number of elements to transfer
first element of the tag for the data in the other controller
Type or Select
SLC Typed Read
data table address in the SLC 500 controller, such as N7:10
number of integers to transfer
first element of int_buffer
SLC Typed Write
first element of int_buffer
number of integers to transfer
data table address in the SLC 500 controller, such as N7:10
SLC Typed Read
data table address in the SLC 500 controller, such as F8:0
number of values to transfer
first element of the tag (controller-scoped) in this controller
for the data
SLC Typed Write
first element of the tag (controller-scoped) in this controller
that contains the data
number of values to transfer
data table address in the SLC 500 controller, such as F8:0
Publication CNET-UM001C-EN-P - November 2005
Peer-to-Peer Messaging