Danfoss VLT HVAC Series Programming Manual page 37

Table of Contents

Advertisement

VLT
®
HVAC Drive Programming Guide
0-31 Custom Readout Min Value
Range:
0.00
Cus-
[0.00 - 100.00 CustomReadoutUnit] This parameter allows the choice of the min. value of the custom defined readout (occurs at zero
tomReadou-
tUnit*
0-32 Custom Readout Max Value
Range:
100.00 Cus-
[par. 0-31 - 999999.99 CustomRea-
tomReadou-
doutUnit]
tUnit*
0-37 Display Text 1
Range:
0 N/A*
[0 - 0 N/A]
0-38 Display Text 2
Range:
0 N/A*
[0 - 0 N/A]
0-39 Display Text 3
Range:
0 N/A*
[0 - 0 N/A]
Function:
speed). It is only possible to select a value different to 0 when selecting a linear unit in par.
Custom Readout Unit
0-30
. For quadratic and cubic units, the minimum value will be 0.
Function:
This parameter sets the max value to be shown when the speed of the motor has reached the set
value for (par.4-13
Motor Speed High Limit [RPM]
Function:
In this parameter, it is possible to write an individual text string for display in the LCP or to be read
via serial communication. If it is to be displayed permanently, select Display Text 1 in par.
Display Line 1.1 Small
0-20
, par. 0-21
par. 0-23
Display Line 2 Large
or par. 0-24
LCP to change a character. Use the
highlighted by the cursor, it can be changed. Use the
character. A character can be inserted by placing the cursor between two characters and pressing
or
.
Function:
In this parameter, it is possible to write an individual text string for display in the LCP or to be read
via serial communication. If it is to be displayed permanently, select Display Text 2 in par.
Display Line 1.1 Small
0-20
, par. 0-21
Display Line 2 Large
par. 0-23
or par. 0-24
LCP to change a character. Use the
highlighted by the cursor, this character can be changed. A character can be inserted by placing the
cursor between two characters and pressing
Function:
In this parameter, it is possible to write an individual text string for display in the LCP or to be read
via serial communication. If it is to be displayed permanently, select Display Text 3 in par.
Display Line 1.1 Small
0-20
,par. 0-21
Display Line 2 Large
par. 0-23
or par. 0-24
LCP to change a character. Use the
highlighted by the cursor, this character can be changed. A character can be inserted by placing the
cursor between two characters and pressing
MG.11.C6.22 - VLT
®
is a registered Danfoss trademark
3 Parameter Description
and par.4-14
Motor Speed High Limit [Hz]
Display Line 1.2 Small
, par. 0-22
Display Line 3 Large
. Use the
and
buttons to move the cursor. When a character is
or
buttons on the LCP to change a
Display Line 1.2 Small
, par. 0-22
Display Line 3 Large
. Use the
and
buttons to move the cursor. When a character is
or
.
Display Line 1.2 Small
, par. 0-22
Display Line 3 Large
. Use the
and
buttons to move the cursor. When a character is
or
.
3
).
Display Line 1.3 Small
,
or
buttons on the
Display Line 1.3 Small
,
or
buttons on the
Display Line 1.3 Small
,
or
buttons on the
3-13