Performing a network function test on HDBaseT
port
The following browsers are supported for this test:
Internet Explorer: IE8 for WinXP, IE9 or higher for Win7, and IE11 for Win8.1 or Win10 is
required.
Chrome: Version 49 or higher is required.
Firefox: Version 46 or higher is required.
Safari: Not supported.
To perform the network function test, complete the following steps.
1.Write down the projector IP.
a.Plug in the power cord to the projector.
b.Connect the PC and projector using a RJ45 cable.
c.Turn on the projector.
d.On the IR remote keypad, select Menu > Configuration > Communications > LAN.
e.Make sure DHCP is disabled.
f.Write down the following information:
The IP address: 192.168.0.100 (default)
The Subnet Mask: 255.255.255.0 (default)
In Network settings, set the projector IP address.
See
Performing a network function test on the network port
3.Read the projector information.
See
Performing a network function test on the network port
Performing a RS232 and video function test on
HDBaseT port
To perform the RS232 and video function test, complete the following steps.
1.Connect the CH-506TX, projector and PC as shown in step 5.
2.Select the signal source HDBaseT.
3.On the IR remote keypad, press Menu > Configuration > Communications> Serial port >
HDBaseT.
4.Set the PC Baud Rate to 115200.
5.Input the RS232 command (SYS?).