Ventilation and cooling
Vents and louvers provide ventilation, both for intake and exhaust, keeping the projector
components within their operating temperature specifications.
Do not install the projector near a radiator, heat register, or within an enclosure. To ensure
adequate airflow, follow the requirements specified in the line drawing (P/N: 020-001122-XX) and
never block or cover the vents.
When replacing fans, ensure you confirm the fan direction for airflow. The correct orientation of the
fan also ensures that the fan harness reaches the connector.
Replacing fans 1, 2, and 3
The fans 1, 2, or 3 draw the hot air out of the projector and provides exhaust cooling for the light
engine and electronics.
1. Remove the top cover.
See
Removing the top cover
2. Remove the right-side cover.
See
Removing the right-side cover
3. To separate the affected fan from the right-side cover, remove the corresponding four M3
screws with a Phillips #1 screwdriver.
4. Replace the affected fan.
5. To re-install, follow these steps in reverse order.
Replacing fans 5 and 7
The fans 5 and 7 draw the air into the projector and provides exhaust cooling for the front laser driver
bank and rear laser driver bank.
1. Remove the top cover.
GS Series 1075 Service Manual
020-001236-02 Rev. 1 (12-2019)
on page 63.
on page 65.
70