Maintenance And Cleaning; Guidelines For Cleaning - Christie GS Series Service Manual

Hide thumbs Also See for GS Series:
Table of Contents

Advertisement

Maintenance and cleaning

Maintain the cleanliness of all internal components during any service procedure. All of the projector
optics must remain free of contaminants to perform at the level specified. Even a small amount of dust
or a fingerprint may degrade the image or cause a noticeable reduction of brightness.
Always power down and disconnect/disengage all power sources to the projector before servicing or
cleaning the lens or before any of the projection head covers or doors are loosened and removed. If
the seal is broken while the intake fans are still operating, internal components are immediately
vulnerable to contamination from inbound particles.
Notice. If not avoided, the following may result in equipment or property damage.
• Avoid touching optical elements.
• Always wear clean, lint-free gloves when handling the product.

Guidelines for cleaning

Use the following guidelines when cleaning components.
Component
Combiner
Illumination optics system Never touch or blow on exposed components.
Color wheel module
Illumination system,
internal lenses/prisms
Light engine components
Light engine, DMD panels
Fan
GS Series 1075 Service Manual
020-001236-02 Rev. 1 (12-2019)
Preventative measures
Never touch or blow on interior components.
Never bend the heatsink of the combiner and
handle by the housing only. Wear gloves
(supplied).
Wear gloves (supplied).
Never touch or blow on the glass surface.
Wear gloves (supplied).
Never touch or blow on interior components.
Wear gloves (supplied)
Normally the internal parts should
not be accessed.
Never touch or blow on components.
Wear gloves (supplied).
Never touch or blow on the panels.
Check for dust build-up on blades. Inspect
harness connection for proper seating. Never
touch or blow on the fan blade.
Service guidelines
How to clean
Remove any contaminants with pure
isopropyl alcohol and a clean lint-free
cloth.
Use ionized pneumatic guns only.
Keep imaging components and
yourself grounded at all times.
Blow off particles with clean, dry
deionized air.
Blow off particles with clean, dry
deionized air. If necessary, wipe in a
single direction with a clean high-
quality optical cloth.
Blow off particles with clean, dry
deionized air. If necessary, use a Q-
tip with pure isopropyl alcohol on the
glass surface. Never touch the
imaging panels. The green imaging
panel also has glass behind it.
Blow off particles with clean, dry
deionized air.
Blow off particles with clean, dry
deionized air.
14

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dhd1075-gsDwu1075-gs

Table of Contents