Trigger Subsystem; Tsweep Subsystem; Unit Subsystem - R&S SMA100A Application Notes

Remote emulation modes with signal generators
Table of Contents

Advertisement

1GP71_0E
AN680XX emulation mode
Status
Command / Function / Remark / Limitation
SYSTem:LANGuage value
Select / Query the remote-control language.
Value:
"SCPI" | "NATIVE" | "TMSL" | "EXIT"
Remark:
"SCPI", "NATIVE" and "TMSL" are not supported.
"EXIT" has to be used to return to the instruments native SCPI-language.
SYSTem:PRESet
Preset instrument.
Remark:
For more information, please see *RST command.
SYSTem:VERSion?
Query the SCPI software version.
Remark:
YYYY.V is returned.

TRIGger Subsystem

Status
Command / Function / Remark / Limitation
TRIGger[:SEQuence | :STARt][:IMMediate]
Trigger a sweep.
TRIGger[:SEQuence | :STARt]:SOURce value
Select / Query the trigger source.
Value:
BUS | EXTern | HOLD | IMMediate
Default:
BUS
Remark:
HOLD is not supported.

TSWeep Subsystem

Status
Command / Function / Remark / Limitation
TSWeep
Take a sweep.

UNIT Subsystem

Status
Command / Function / Remark / Limitation
Table 45: SYSTEM subsystem
Table 46: TRIGGER subsystem
Table 47: TSWEEP subsystem