Initialize Subsystem - R&S SMA100A Application Notes

Remote emulation modes with signal generators
Table of Contents

Advertisement

1GP71_0E
HP8643 emulation mode
Status
Command / Function / Remark / Limitation
[:SOURce:]FREQuency:SPAN value
Set / Query the rf carrier sweep frequency span.
Value:
value HZ | KHZ | MHZ | MAHZ | GHZ] | UP | DOWN | MINimum | MAXimum
Default:
freqmax - freqmin
[SOURce:]FREQuency:SPAN:STEP[:INCRement] value
Alias to FREQuency[:CW]:STEP[:INCRement] value
[:SOURce:]FREQuency:MANual value
Set / Query the actual rf carrier frequency in stepped sweep.
Value:
value [HZ | KHZ | MHZ | MAHZ | GHZ] | MINimum | MAXimum
Default:
freqmin
[:SOURce:]FREQuency:OFFSet value
Set / Query the rf carrier frequency offset.
Value:
value [HZ | KHZ | MHZ | MAHZ | GHZ] | MINimum | MAXimum
Default:
0.0 HZ
[:SOURce:]FREQuency:MULTiplier value
[:SOURce:]FREQuency:SYNThesis value
[:SOURce:]FREQuency:SYNThesis:AUTO value
[:SOURce:]FREQuency:MODE value
Set / Query the rf carrier frequency operation mode.
Value:
CW | SWEep
Default:
CW
[:SOURce:]FREQuency:INSTantaneous?
Table 111: FREQuency subsystem commands

INITialize Subsystem

Status
Command / Function / Remark / Limitation
INITialize[:IMMediate]
Starts a single or continuous sweep.
INITialize:ABORt
Terminates a sweep.
119
Rohde & Schwarz

Advertisement

Table of Contents
loading

This manual is also suitable for:

Smb100aSmf100a

Table of Contents