Sweep Mode/Type; Sweep Control - R&S SMA100A Application Notes

Remote emulation modes with signal generators
Table of Contents

Advertisement

1GP71_0E
AF2040 emulation mode
Status
Command / Function / Remark / Limitation
SWEEP:INTF?
Query informations on modulation oscillator frequency sweep settings.
SWEEP:INTF:VALUE?
Query informations on current modulation oscillator frequency marker settings.
SWEEP:HOP?
Query informations on frequency hopping sweep settings.

Sweep Mode/Type

Status
Command / Function / Remark / Limitation
SWEEP:MODE value
Select operation mode of sweep generator.
Value:
SNGL | CONT | EXT
Default:
SNGL
SWEEP:TYPE value
Select type of sweep.
Value:
OFF | CFRQ | RFLV | LFGF | LFGL | INTF1 | INTF2 | INTF3 | INTF4 | INTF5 | INTF6
| HOP
Default:
CRFQ
Remark:
HOP is not supportted
SWEEP?
Query informations on sweep mode and type.

Sweep Control

Status
Command / Function / Remark / Limitation
SWEEP:GO
Commence sweep.
SWEEP:CALC
Initiate pre calculations.
SWEEP:HALT
Pause sweep.
SWEEP:CONT
Continue sweep.
Remark:
Identical to SWEEP:GO
Table 28: Sweep Operation
Table 29: Sweep Mode/Type
34
Rohde & Schwarz

Advertisement

Table of Contents
loading

This manual is also suitable for:

Smb100aSmf100a

Table of Contents