Source Subsystem - R&S SMA100A Application Notes

Remote emulation modes with signal generators
Table of Contents

Advertisement

AN680XX emulation mode

SOURce Subsystem

Status
Command / Function / Remark / Limitation
[:SOURce:]CORRection[:STATe] value
[:SOURce:]CORRection:CSET:SELect value
[:SOURce:]FREQuency[:CW | :FIXed] value
Set / Query the RF output frequency.
Value:
freqmin...freqmax [HZ | KHZ | MHZ | GHZ] | MIN | MAX | UP | DOWN
Default:
0.5 * (freqmin + freqmax)
[:SOURce:]FREQuency[:CW | :FIXed]:STEP[:INCRement] value
Set / Query the frequency increment step size.
Value:
1KHZ ... (freqmax - freqmin) [HZ | KHZ | MHZ | GHZ]
Default:
0.1 GHz
[:SOURce:]FREQuency:CENTer value
Set / Query the RF output center frequency.
Value:
freqmin ... freqmax [HZ | KHZ | MHZ | GHZ]
Default:
0.5 * (freqmin + freqmax)
[:SOURce:]FREQuency:MODE value
Set / Query the frequency operation mode.
Value:
CW | FIXed | SWEep[1] | SWCW | ALSW | LIST[1] | LIST2 | LIST3 | LIST4
Default:
CW
Remark:
ALSW, LIST<n> are not supported.
SWCE is identical to CW and FIXed.
SWEep[1] is used for frequency sweep, SWEep2 is used for power sweep.
[:SOURce:]FREQuency:MULTiplier value
Set / Query the factor for the frequency display.
Value:
0.1 ... 14
Default:
1.0