Modulation Subsystem; Phase Subsystem; Pm Subsystem - R&S SMA100A Application Notes

Remote emulation modes with signal generators
Table of Contents

Advertisement

1GP71_0E
HP8643 emulation mode

MODulation Subsystem

Status
Command / Function / Remark / Limitation
MODulation[:STATe] value
Set / Query the general (activation) state of the modulation.
Value:
ON | OFF | 1 | 0
Default:
OFF
Table 115: MODulation subsystem commands

PHASe Subsystem

Status
Command / Function / Remark / Limitation
PHASe[:ADJust] value
Set / Query the rf carrier's phase (relative to reference).
Value:
Value [DEG | RAD] | UP | DOWN | MINimum | MAXimum
Default:
0.0 DEG
PHASe[:ADJust]:STEP[:INCRement] value
Set / Query the rf carrier's phase step size.
Value:
Value [DEG | RAD] | MINimum | MAXimum
Default:
1.0 DEG
PHASe:REFerence
Resets the phase value to 0.0 DEG without changing the phase of rf carrier.

PM Subsystem

Status
Command / Function / Remark / Limitation
[SOURce:]PM[:DEViation] value
Set / Query the rf carrier modulation deviation.
Value:
value [DEG | RAD] MINimum | MAXimum
Default:
0.0 RAD
[SOURce:]PM[:DEViation]:STEP[:INCRement] value
Set / Query the rf carrier modulation deviation step size.
Value:
value [DEG | RAD] | MINimum | MAXimum
Default:
0.0 RAD
Table 116: PHASe subsystem commands