R&S SMB100B Getting Started
R&S SMB100B Getting Started

R&S SMB100B Getting Started

Rf signal generator
Table of Contents

Advertisement

®
R&S
SMB100B
RF Signal Generator
Getting Started
(>F:]2)
1422104502

Advertisement

Table of Contents
loading

Summary of Contents for R&S SMB100B

  • Page 1 ® R&S SMB100B RF Signal Generator Getting Started (>F:]2) 1422104502...
  • Page 2 ® This document describes the R&S SMB100B, stock no. 1422.1000.02 and its options. © 2019 Rohde & Schwarz GmbH & Co. KG Mühldorfstr. 15, 81671 München, Germany Phone: +49 89 41 29 - 0 Fax: +49 89 41 29 12 164 Email: info@rohde-schwarz.com...
  • Page 3: Table Of Contents

    4.2 Unpacking and Checking..............15 4.3 Choosing the Operating Site............. 15 4.4 Setting Up the R&S SMB100B............16 4.4.1 Placing the R&S SMB100B on a Bench Top.........16 4.4.2 Mounting the R&S SMB100B in a Rack..........17 4.5 Important Aspects for Test Setup............18 4.6 Connecting to Power................
  • Page 4 ® Contents R&S SMB100B 4.7 Connecting to LAN................20 4.8 Connecting USB Devices..............20 4.9 Connecting to RF................21 4.10 Connecting to Ref In/Ref Out.............23 4.11 Switching On or Off................24 5 Instrument Tour..............27 5.1 Front Panel Tour..................27 5.1.1 Touchscreen..................28 5.1.2 Utility Keys....................
  • Page 5 ® Contents R&S SMB100B 7.1 Possible Ways to Operate the Instrument........46 7.2 Means of Manual Interaction..............47 7.3 Understanding the Display Information..........47 7.3.1 Status Bar..................... 48 7.3.2 Tile Diagram..................48 7.3.3 Taskbar....................49 7.3.4 Additional Display Characteristics............50 7.4 Accessing the Functionality.............. 51 7.5 Entering Data..................52...
  • Page 6 ® Contents R&S SMB100B Getting Started 1422.1045.02 ─ 03...
  • Page 7: Preface

    R&S SMB100B Key Features Preface The R&S SMB100B is a new high-performance signal generator developed to meet demanding customer requirements. Offering excellent signal characteristic and straightforward and intuitive operation, the signal generator makes signal generation fast and easy. Key Features The R&S SMB100B is a new high-performance signal generator developed to...
  • Page 8: Safety And Regulatory Information

    Safety and Regulatory Information R&S SMB100B Safety Instructions Safety and Regulatory Information The product documentation helps you use the R&S SMB100B safely and effi- ciently. Follow the instructions provided here and in the Chapter 2.1, "Safety Instructions", on page 8.
  • Page 9 ® Safety and Regulatory Information R&S SMB100B Safety Instructions If any part of the product is damaged or broken, stop using the product. Never open the casing of the product. Only service personnel authorized by Rohde & Schwarz are allowed to repair the product. Contact Rohde & Schwarz customer service at http://www.customersupport.rohde-schwarz.com.
  • Page 10 ® Safety and Regulatory Information R&S SMB100B Safety Instructions Take the following measures for your safety: ● Before switching on the product, ensure that the voltage and frequency indica- ted on the product match the available power source. If the power adapter does not adjust automatically, set the correct value and check the rating of the fuse.
  • Page 11: Labels On R&S Smb100B

    Table 2-1: Labels regarding R&S SMB100B and environment safety Labeling in line with EN 50419 for disposal of electrical and electronic equipment after the product has come to the end of its service life. For more information, see the prod- uct user manual, chapter "Disposal".
  • Page 12: Documentation Overview

    Getting Started Manual Introduces the R&S SMB100B and describes how to set up and start working with the product. Includes basic operations, typical measurement examples, and gen- eral information, e.g. safety instructions, etc. A printed version is delivered with the instrument.
  • Page 13: Instrument Security Procedures

    Rohde & Schwarz information system (GLORIS, https://gloris.rohde- schwarz.com). Instrument Security Procedures Deals with security issues when working with the R&S SMB100B in secure areas. It is available for download on the Internet. Basic Safety Instructions Contains safety instructions, operating conditions and further important informa- tion.
  • Page 14: Application Notes, Application Cards, White Papers, Etc

    ® Documentation Overview R&S SMB100B Application Notes, Application Cards, White Papers, etc. Application Notes, Application Cards, White Papers, etc. These documents deal with special applications or background information on particular topics. www.rohde-schwarz.com/application/smb100b Getting Started 1422.1045.02 ─ 03...
  • Page 15: Preparing For Use

    See also "Lifting and carrying the product" on page 9. ► Use the carrying handle at the side for lifting and carrying the R&S SMB100B. For mounting the R&S SMB100B in a rack, see Chapter 4.4.2, "Mounting the R&S SMB100B in a Rack",...
  • Page 16: Setting Up The R&S Smb100B

    Electromagnetic compatibility classes The electromagnetic compatibility (EMC) class indicates where you can operate the R&S SMB100B. The EMC class of the R&S SMB100B is given in the data sheet under "General data". ● Class B equipment is suitable for use in: –...
  • Page 17: Mounting The R&S Smb100B In A Rack

    ● Keep a minimum distance of 10 cm between the fan openings of the R&S SMB100B and any object in the vicinity. ● Do not place the R&S SMB100B next to heat-generating equipment such as radiators or other instruments. 4.4.2 Mounting the R&S SMB100B in a Rack...
  • Page 18: Important Aspects For Test Setup

    Important Aspects for Test Setup To mount the R&S SMB100B in a rack 1. Use an adapter kit that fits the dimensions of the R&S SMB100B to prepare the instrument for rack mounting. For information on the dimensions, see data sheet.
  • Page 19: Connecting To Power

    ● Ensure that connected external devices comply with EMC regulations. Signal input and output levels Information on signal levels is provided in the data sheet. Keep the signal levels within the specified ranges to avoid damage to the R&S SMB100B and connected devices. Preventing electrostatic discharge (ESD) Electrostatic discharge is most likely to occur when you connect or disconnect a DUT.
  • Page 20: Connecting To Lan

    Connecting USB Devices Connecting to LAN You can operate the R&S SMB100B via LAN (local area network) or you can operate it locally. This section describes how to connect the instrument to a LAN to operate or control the instrument remotely via a PC in a LAN.
  • Page 21: Connecting To Rf

    To prepare for connecting to "RF" 1. If the R&S SMB100B is switched on, deactivate the RF output, before con- necting an RF cable to the RF connector. In the home screen, select the block "Level" > "RF ON > Off".
  • Page 22 ® Preparing for Use R&S SMB100B Connecting to RF To connect to non-screwable connectors (BNC) ► To connect the RF cable with the "RF" connector, proceed as follows: a) Carefully align the connector of the cable and the "RF" connector along a common axis.
  • Page 23: Connecting To Ref In/Ref Out

    ► NOTICE! If you set a too high output level, the reverse power can exceed a limit forcing the R&S SMB100B to switch off the RF output. Set an RF output level that is not higher than the maximum permissible RF power as given in the data sheet.
  • Page 24: Switching On Or Off

    ® Preparing for Use R&S SMB100B Switching On or Off d) Torque the nut to the specified limit using a calibrated torque wrench. Hold the opposite connector part stationary with a spanner. For torque limits of the most relevant connector types, see Table 4-1.
  • Page 25 The LED changes to green. The R&S SMB100B boots. When starting for the first time, the R&S SMB100B starts with the default set- tings. When restarting the instrument, the settings depend on the instrument configuration before shut-down. See the chapter "Saving and Recalling Instrument Settings" in the user man- ual.
  • Page 26 To disconnect from power The R&S SMB100B is in the standby state. 1. NOTICE! Risk of data loss. If you disconnect the R&S SMB100B from power when it is in the ready state, you can lose settings and data. Shut it down first.
  • Page 27: Instrument Tour

    Rear Panel Tour This section explains the control elements and the connectors of the R&S SMB100B with the aid of the front and rear views. For specifications of the interfaces, refer to the data sheet. The meanings of the labels on the R&S SMB100B are described in Chapter 2.2,...
  • Page 28: Touchscreen

    ● "Maintenance" in the user manual, for instructions on cleaning the screen. 5.1.2 Utility Keys The utility keys set the R&S SMB100B to a defined state, and provide access to basic settings and information on assistance. Getting Started 1422.1045.02 ─ 03...
  • Page 29: On/Standby

    ® Instrument Tour R&S SMB100B Front Panel Tour Table 5-1: Utility keys Utility Key Assigned functions [Preset] Sets the instrument to a defined state [Local] Switches from remote control to local (manual) control [Setup] Accesses the general instrument settings [Help] Displays context-sensitive help text 5.1.3...
  • Page 30: Navigation Controls

    ® Instrument Tour R&S SMB100B Front Panel Tour Table 5-3: Keys on the keypad Type of key Description Alphanumeric keys Enter numbers and (special) characters in edit dialog boxes. Decimal point Inserts a decimal point "." at the cursor position.
  • Page 31: Navigation Keys

    ® Instrument Tour R&S SMB100B Front Panel Tour Table 5-4: Editing keys Type of key Description [Esc] key Closes all kinds of dialog boxes, if the edit mode is not active. Quits the edit mode, if the edit mode is active. In dialog boxes that contain a "Cancel"...
  • Page 32: Display Keys

    ® Instrument Tour R&S SMB100B Rear Panel Tour 5.1.7 Display Keys The display keys arrange different windows on the display. Table 5-6: Display keys Display key Assigned functions [Home] Returns to the initial feature screen. [Next window] Toggles between the entry fields in the taskbar.
  • Page 33: Connectors

    The interface is in compliance with the standards IEC 625, IEEE 488 and SCPI. Use this interface to connect a computer for remote control of the R&S SMB100B. To set up the connection, use high-quality shielded cables. See "Cable selection and electromagnetic interference (EMI)"...
  • Page 34 Female USB In connector (USB type B), for example for remote control. How to: Chapter 4.8, "Connecting USB Devices", on page 20 RJ-45 connector to connect the R&S SMB100B to a LAN for remote control, remote operation, and data transfer. How to: Chapter 4.7, "Connecting to LAN",...
  • Page 35 ® Instrument Tour R&S SMB100B Rear Panel Tour Pulse Video Output of the internal pulse generator signal or the looped through pulse signal from Pulse Ext. connector (video signal). Pulse Ext. Input for an external pulse modulation signal or an external trigger/gate signal for the pulse generator.
  • Page 36: Trying Out The Instrument

    We start to generate a simple unmodulated signal. In this example, the R&S SMB100B can be in its minimal configuration. 1. On the R&S SMB100B front panel, press the [Preset] key to set a defined ini- tial instrument state. 2. Set the frequency: a) In the "Status Bar", tap the "Frequency"...
  • Page 37 ® Trying Out the Instrument R&S SMB100B Generating an Unmodulated Carrier The on-screen key pad closes and the frequency value is displayed. 3. To set the signal level, tap the "Level" field and enter the level in the same way.
  • Page 38 R&S SMB100B Generating an Unmodulated Carrier The blue colored "RF On" icon indicates that the RF output is activated. The R&S SMB100B provides the 6 GHz signal at the RF connector at the front panel. Getting Started 1422.1045.02 ─ 03...
  • Page 39 ® Trying Out the Instrument R&S SMB100B Generating an Unmodulated Carrier Figure 6-1: Generating an unmodulated signal Alternative ways to access the instrument functions To fulfill the same task, you can also use the front panel keys or the setting parameters provided in the frequency and level dialogs.
  • Page 40: Generating An Rf Frequency Sweep Signal

    Trying Out the Instrument R&S SMB100B Generating an RF Frequency Sweep Signal Connect RF of the R&S SMB100B to a signal analyzer, for example ® R&S FSW, to display the generated signal. For the required settings of the signal analyzer, refer to its user manual or its online help.
  • Page 41 ® Trying Out the Instrument R&S SMB100B Generating an RF Frequency Sweep Signal a) Select "Mode > Auto" to run the sweep continuously. b) Select "Shape > Sawtooth" to set the waveform shape of the sweep signal. c) Select "Spacing > Linear", to determine the calculation method for the fre- quency shift of a step.
  • Page 42: Saving And Recalling Settings

    7. Close the sweep dialog. (Alternatively, tap the "Home" button to minimize the dialog. The R&S SMB100B indicates the "Sweep" dialog as active dialog in the task bar.) 8. To activate the RF signal output, select "Level" > "RF On".
  • Page 43 ® Trying Out the Instrument R&S SMB100B Saving and Recalling Settings To save the instrument settings in a file We assume, a test configuration as described in Chapter 6.2, "Generating an RF Frequency Sweep Signal", on page 40. 1. Press the [Setup] key on the front panel.
  • Page 44 ® Trying Out the Instrument R&S SMB100B Saving and Recalling Settings 2. Press the [Setup] key on the front panel. 3. In the "Setup" menu, select "Settings > Save/Recall". 4. In the "Save/Recall" dialog, select "Operation Mode > Recall". Navigate to the directory the file is saved in and select the MyTestSignal file.
  • Page 45 ® Trying Out the Instrument R&S SMB100B Saving and Recalling Settings Try out the following: ● Touch and hold a spot in the tile diagram for at least 1 second to access the context-sensitive menu. ● Select "Mark All Parameters Changed from Preset".
  • Page 46: Instrument Control

    ® Instrument Control R&S SMB100B Possible Ways to Operate the Instrument Instrument Control This chapter provides an overview on how to work with the R&S SMB100B. It covers the following topics: ● Possible Ways to Operate the Instrument............46 ● Means of Manual Interaction................47...
  • Page 47: Means Of Manual Interaction

    Understanding the Display Information The home screen of the R&S SMB100B displays all main settings and generator states, divided into three main operation areas. Getting Started 1422.1045.02 ─ 03...
  • Page 48: Status Bar

    The status bar at the top of the screen indicates the RF frequency and the level of the output signal provided to the DUT. You can set both parameters directly here. 7.3.2 Tile Diagram The tile diagram is the main entry to the settings of the R&S SMB100B. Getting Started 1422.1045.02 ─ 03...
  • Page 49: Taskbar

    ® Instrument Control R&S SMB100B Understanding the Display Information Tile Access to: ● "Modulation" Analog and stereo , and pulse modulation settings ● Built in LF generator ● "System Config" "Save/Recall": settings for saving and loading instrument configura- tions ●...
  • Page 50: Additional Display Characteristics

    ® Instrument Control R&S SMB100B Understanding the Display Information Active dialogs Indicates the dialog name of each active dialog in a separate button. "Info" key Provides access to status and error messages. Note: The warning symbol signifies a permanent error message.
  • Page 51: Accessing The Functionality

    ® Instrument Control R&S SMB100B Accessing the Functionality Within the entire screen display, including single parameters, you can access context-sensitive menus that provide some additional functions. Accessing the Functionality All functionalities are provided in dialog boxes as known from computer pro- grams.
  • Page 52: Entering Data

    ® Instrument Control R&S SMB100B Entering Data To open a dialog box ► Perform one of the following actions: ● Tap the required tile, and then the menu entry. ● Tap the minimized view (button) on the taskbar. Some of the utility keys access a dedicated dialog, too.
  • Page 53: Entering Numeric Parameters

    ® Instrument Control R&S SMB100B Entering Data 3. Deletes the entry to the left of the cursor. 4. Enter your correction. Completing the entry ► Press the [Enter] key or the rotary knob. Aborting the entry ► Press the [Esc] key.
  • Page 54: Entering Alphanumeric Parameters

    ® Instrument Control R&S SMB100B Getting Information and Help 7.5.2 Entering Alphanumeric Parameters If a field requires alphanumeric input, you can use the on-screen keyboard to enter letters and (special) characters. 7.5.3 Undo and Redo Actions Accessed via the context-sensitive menus, "Undo" allows you to restore one or more actions on the instrument.
  • Page 55 ® Instrument Control R&S SMB100B Getting Information and Help Contents of the help dialog box The help dialog box covers two main areas: ● "Contents" - contains a table of help contents ● "Topic" - contains a specific help topic The help system also provides an "Index"...
  • Page 56: Remote Control

    The corresponding help topic is displayed. Remote Control In addition to working with the R&S SMB100B interactively, located directly at the instrument, it is also possible to operate and control it from a remote PC. The R&S SMB100B supports various methods for remote control: ●...
  • Page 57: Remote Operation Over Vnc

    Thus, remote operation of the instrument is possible. Instrument control from a remote computer To access the basic utility functions of the R&S SMB100B, perform a right mouse click the block diagram and select "Key Emulation". A key panel to the right of the block diagram gives access to the utility func- tions provided by the front panel keys.
  • Page 58: Contacting Customer Support

    ® Contacting Customer Support R&S SMB100B Contacting Customer Support Technical support – where and when you need it For quick, expert help with any Rohde & Schwarz equipment, contact one of our Customer Support Centers. A team of highly qualified engineers provides tele- phone support and works with you to find a solution to your query on any aspect of the operation, programming or applications of Rohde &...
  • Page 59: Index

    ® Index R&S SMB100B Index Display Active elements ........50 Active elements ........50 Context-sensitive menu ...... 50 Alphanumeric parameters ....... 54 Info line ..........50 Application cards ........14 Information .......... 47 Application notes ........14 On-screen keypad ......50 Overview ..........
  • Page 60 ® Index R&S SMB100B Navigation ★ (User) ..........32 Keys ............ 31 Navigation controls Access on a remote computer .... 57 Arrow ..........31 Overview ..........30 Numeric data entry ........52 Backspace .......... 30 Numeric parameters ........ 53 Down ...........31 Emulation ..........
  • Page 61 ® Index R&S SMB100B Softkey bar see Taskbar ........49 Standby ........... 29 Status bar Display ..........48 Stereo L/R connector ......34 Switching On or off ..........24 Tab labels ..........50 Text entry ..........52 Tile diagram Display ..........48 Tooltips Show ...........

Table of Contents