1GP71_0E
AF2040 emulation mode
Status
Command / Function / Remark / Limitation
MODE value
Set modulation mode.
Value:
Combinations of AM, AM1, AM2, FM, FM1, FM2, PM, PM1, PM2, WBFM, PULSE,
SDM, DDM, VOR, ILS, DME
Default:
FM
Remark:
Only the following mode combinations are supported:
AM1
FM1
PM1
PULSE
AM1, AM2
FM1, FM2
PM1, PM2
AM1, FM1
AM1, PM1
PULSE,FM1
PULSE,PM1
PULSE, FM1, FM2
PULSE, PM1, PM2
MODE?
Query informations on modulation mode settings.
•
Modulation Control
Status
Command / Function / Remark / Limitation
MOD:ON
Turn modulation globally on
MOD:OFF
Turn modulation globally off.
MOD?
Query informations modulation control settings.
•
Frequency Modulation
Status
Command / Function / Remark / Limitation
Table 12: Modulation mode
Table 13: Modulation control
20