Special Function - R&S SMA100A Application Notes

Remote emulation modes with signal generators
Table of Contents

Advertisement

HP8662 emulation mode
Value:
UP | DN | AO | MO | M1 | M2 | M3 | M4 | N1 | N2 | N4 | N5 | T1 | T2 | T3 | T4 | T5 |
W1 | W2 | W3 | W4
Remark:
T1, T2, T3 are not supported.
TR
Executes function, specified by command CT.
@1 value
Set service request mask
Value:
0x00 ... 0xFF
Remark:
Layout of status byte is different in both systems.
RM
Query service request mask
Remark:
Layout of status byte is different in both systems.
MS
Query the instrument status.
Remark:
Status codes from SM* are returned
L1
Front panel long learn mode
L2
Front panel fast learn mode
@2
Select deferred execution mode
@3
Select immediate execution mode
SP
See Special Functions
Table 156: Other

Special Function

Status
Command / Function / Remark / Limitation
BLAP00
see SP00
BLAP10
see SP10
BLAP11
see SP11
BLAP12
see SP12
1GP71_0E