IBM Flex System x440 Compute Node Installation And Service Manual

IBM Flex System x440 Compute Node Installation And Service Manual

Processor-based server
Table of Contents

Advertisement

Quick Links

IBM Flex System x440 Compute Node
Types 7917 and 2584
Installation and Service Guide

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Flex System x440 Compute Node and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for IBM Flex System x440 Compute Node

  • Page 1 IBM Flex System x440 Compute Node Types 7917 and 2584 Installation and Service Guide...
  • Page 3 IBM Flex System x440 Compute Node Types 7917 and 2584 Installation and Service Guide...
  • Page 4 Before using this information and the product it supports, read the general information in “Notices” on page 559, the Warranty Information document, and the IBM Safety Information and the Environmental Notices and User Guide documents on the IBM Documentation CD.
  • Page 5: Table Of Contents

    Resolving conflicts with the IMM2 LAN over Related documentation . USB interface . . 50 The IBM Documentation CD . Hardware and software requirements . Chapter 5. Parts listing, Types 7917 Using the Documentation Browser . and 2584 ....51 Notices and statements in this document .
  • Page 6 Index ....567 Before you call . . 555 Using the documentation . . 556 IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 7: Safety

    Ennen kuin asennat tämän tuotteen, lue turvaohjeet kohdasta Safety Information. Avant d'installer ce produit, lisez les consignes de sécurité. Vor der Installation dieses Produkts die Sicherheitshinweise lesen. Prima di installare questo prodotto, leggere le Informazioni sulla Sicurezza. © Copyright IBM Corp. 2012...
  • Page 8: Guidelines For Trained Service Technicians

    If you identify IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 9: Guidelines For Servicing Electrical Equipment

    Make sure that the insulation is not frayed or worn. 4. Remove the cover. 5. Check for any obvious non-IBM alterations. Use good judgment as to the safety of any non-IBM alterations. 6. Check inside the system for any obvious unsafe conditions, such as metal filings, contamination, water or other liquid, or signs of fire or smoke damage.
  • Page 10: Safety Statements

    Be sure to read all caution and danger statements in this documentation before you perform the procedures. Read any additional safety information that comes with your system or optional device before you install the device. viii IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 11 Statement 1 DANGER Electrical current from power, telephone, and communication cables is hazardous. To avoid a shock hazard: v Do not connect or disconnect any cables or perform installation, maintenance, or reconfiguration of this product during an electrical storm. v Connect all power cords to a properly wired and grounded electrical outlet. v Connect to properly wired outlets any equipment that will be attached to this product.
  • Page 12 Hazardous energy is present when the blade is connected to the power source. Always replace the blade cover before installing the blade. UL regulatory information This device is for use only with Listed IBM Flex System Enterprise Chassis. IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 13: Chapter 1. Introduction

    The IBM Flex System x440 Compute Node is supported in the IBM Flex System Enterprise Chassis only. This documentation provides the following information about setting up and...
  • Page 14: Related Documentation

    Service Guide for your IBM Flex System chassis for information to help you prepare for system installation and configuration. To check for updated documentation, go to http://www.ibm.com/supportportal/. IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 15: The Ibm Documentation Cd

    You can also find documentation that is related to IBM Flex System products at http://publib.boulder.ibm.com/infocenter/flexsys/information/index.jsp. The IBM Documentation CD The IBM Documentation CD contains documentation for the compute node in Portable Document Format (PDF). It includes the IBM Documentation Browser to help you find information quickly.
  • Page 16: Notices And Statements In This Document

    2. The operating system in the compute node must provide USB support for the compute node to recognize and use USB media drives and devices. The following table is a summary of the features and specifications of the IBM Flex System x440 computer node.
  • Page 17 Table 1. Features and specifications Environment: The IBM Flex System Microprocessor: One, two or four Upgradeable firmware: All x440 Compute Node complies with multi-core Intel Xeon firmware is field upgradeable. ASHRAE class A3 specifications. microprocessors. Power on Memory: Notes: – Temperature: 5°C - 40°C (41°F - v 48 dual inline memory module 1.
  • Page 18: What Your Compute Node Offers

    – Performance data and details about processes that are running – RAID and controller configuration – Integrated management module 2 status and configuration – System configuration IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 19 You can send the DSA log as a file to a support representative or view the information as a text file or HTML file. For more information, see “IBM Dynamic System Analysis Preboot diagnostic program” on page 65.
  • Page 20 IBM Flex System chassis. This policy is enforced when the initial power is applied to the IBM Flex System chassis or when a compute node is inserted into the IBM Flex System chassis.
  • Page 21: Reliability, Availability, And Serviceability Features

    By using industry standards, IBM Flex System Manager management software supports multiple operating systems and virtualization technologies. For more information, see the "IBM Flex System Manager Software: Installation and Service Guide" at http://ralfss21.raleigh.ibm.com:8099/help/topic/com.ibm.acc.8731.doc/ product_page.html. Reliability, availability, and serviceability features Three of the most important features in compute node design are reliability, availability, and serviceability (RAS).
  • Page 22: Power, Controls, And Indicators

    LED Fault Power USB connector Identify Check log button/LED Fault LED When this yellow LED is lit, it indicates that a system error has occurred in IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 23 When this LED is lit, the identify LED on the IBM Flex System chassis is also lit. The identify LED can be lit and turned off through the CMM led command, the CMM web interface, or IBM Flex System Manager management software (if installed).
  • Page 24 When the compute node is on, pressing this button causes an orderly shutdown of the compute node so that it can be removed safely from the IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 25: Console Breakout Cable

    Use this information for details about turning on the compute node. About this task After you connect the compute node to power through the IBM Flex System chassis, the compute node can be started in any of the following ways: v You can press the power button on the front of the compute node (see “Compute node controls, connectors, and LEDs”...
  • Page 26 See “Compute node controls, connectors, and LEDs” on page 10 for the power LED states. v If a power failure occurs, the IBM Flex System chassis and the compute node can be configured through the CMM power command and the CMM web interface to start automatically when power is restored.
  • Page 27: Turning Off The Compute Node

    IMM2, such as a remote request to turn on the compute node. To remove all power from the compute node, you must remove it from the IBM Flex System chassis. Before you turn off the compute node, shut down the operating system. See the operating-system documentation for information about shutting down the operating system.
  • Page 28: System-Board Layouts

    DIMMs Microprocessor Microprocessor System-board jumpers Use this information to locate the system-board jumpers. The following illustration shows the locations of the jumpers on the system board. IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 29 Low security TPM physical presence Force IMM2 reset The following table describes the function of each jumper on the system board. Jumper number Description Force IMM Reset (J12) For debug purposes only. Low Security (J9101) Three-pin jumper block. The default position are pins 2 and 3 (allow only signed IMM2 to be flashed).
  • Page 30: System-Board Leds

    System-board switches Use this information to locate the system-board switches. The following illustration shows the location of the switch block on the system board. IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 31 U52 and U9020 switch block The following table describes the functions of the switches on switch block SW3. Switch number Description Switch setting Definition U52-1 Password override The default position Changing this switch Open. to the Closed position overrides the power-on password.
  • Page 32 FPGA Configuration Logic U9020-2 Power permission The default position is Changing this switch Open. to the closed position enables WOL and the front panel button. IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 33 Switch number Description Switch setting Definition U9020-3 FPGA mux enable The default position is Changing this switch Open. to the closed position to enable the FPGA MUX keyboard controls U9020-4 Future use only U9020-5, Selecting dongle serial Closed, Closed BE3-1 TX/RX U9020-6 port MUX (U9812) Open, Closed...
  • Page 34 IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 35: Chapter 2. Configuring

    Using IBM ToolsCenter Bootable Media Creator, you can create a single bootable image on supported media (such as CD, DVD, ISO image, USB flash drive, or set of PXE files) that bundles multiple IBM Flex System tools and updates from ®...
  • Page 36: Recovering A Uefi Image

    Note: The user ID that you use to log in to IBM Flex System Manager management software must have sufficient user permissions to manage the compute node. 5. From the Remote Control session, mount the bootable media (using Remote Media).
  • Page 37: Configuring The Compute Node

    7. Update the UEFI code (see “Updating firmware and device drivers” on page 23). 8. Turn off the compute node and remove it from the IBM Flex System chassis (see “Turning off the compute node” on page 15 and “Removing a compute node from a chassis”...
  • Page 38: Using The Setup Utility

    To start the Setup utility locally, complete the following steps: 1. If the compute node is turned on, turn off the compute node (see “Turning off the compute node” on page 15. IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 39 2. If necessary, connect a keyboard, monitor, and mouse to the console breakout cable and connect the console breakout cable to the compute node). 3. Turn on the compute node (see “Turning on the compute node” on page 13). 4. When the prompt Press <F1> Setup is displayed, press F1. If you have set an administrator password, you must type the administrator password to access the full Setup utility menu.
  • Page 40 Select this choice to enable or disable non-system-board PXE for legacy mode. – System Security Select this choice to view or change the security options for Trusted Platform Module (TPM). – Integrated Management Module IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 41 Select this choice to view or change the settings for the integrated management module II (IMM2). - Commands on USB Interface Select this choice to specify whether the Ethernet over USB interface is enabled or disabled. Note: This option is primarily for older operating systems that have problems with USB communications device class (CDC) Ethernet interfaces.
  • Page 42 If you forget the power-on password, you can regain access to the compute node either by removing the CMOS battery and then reinstalling it (see “Removing IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 43: Setting The Boot Protocol To Boot From Legacy Devices Using The Setup Utility

    the CMOS battery” on page 496 and “Installing the CMOS battery” on page 497) or by using the power-on password override switch (see “System-board switches” on page 18). v Save Settings Select this choice to save the changes that you have made in the settings. v Restore Settings Select this choice to cancel the changes that you have made in the settings and restore the previous settings.
  • Page 44: Using The Boot Selection Menu Program

    If you omit an optional parameter, the default is used. v Although the command syntax is shown in mixed case, the commands are not case sensitive. IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 45 Locally: Keyboard Controller Style (KCS) This access method uses the IPMI/KCS interface. The IPMI driver must be installed; with some operating systems, the IPMI driver is installed by default. The ASU provides the corresponding mapping layer. Procedure To update the UUID, in the ASU command-line interface, enter the following command: asu set SYSTEM_PROD_DATA.SysInfoUUID uuid where uuid is the user-assigned hexadecimal value, up to 16 bytes, that identifies...
  • Page 46 LAN IP address of the IMM2. userid is the IMM2 account name (1 of 12 accounts). The default is USERID. IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 47: Configuring A Raid Array

    You can use two hard disk drives in the compute node to implement and manage RAID level-0 (striping) or RAID level-1 (mirror) arrays in operating systems that are listed on the ServerProven list at http://www.ibm.com/systems/info/ x86servers/serverproven/compat/us/. For the compute node, you must configure the RAID by using the LSI Configuration Utility program.
  • Page 48: Using The Lsi Logic Configuration Utility

    LAN-on-motherboard (LOM) controller integrated on the system board. The LOM provides the following features: v Two operational mode choices: – One-port physical NIC mode (pNIC), multichannel disabled, which is the default. IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 49 Preboot Execution Environment, UEFI, and Legacy PXE. v Wake on LAN (WOL). v SRIOV support. v ISCSI or FCoE capabilities, which can be enabled through IBM Features on Demand. When enabled, the ISCSI or FCoE operations are supported on the second vNIC of the physical port.
  • Page 50 IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 51: Chapter 3. Installing The Operating System

    3. From IBM Flex System Manager Chassis Manager, select the compute node. In the Actions column, select Remote Control. Note: The user ID that you use to log in to IBM Flex System Manager management software must have sufficient user permissions to manage the compute node.
  • Page 52: Using The Serverguide Setup And Installation Cd

    3. From IBM Flex System Manager Chassis Manager, select the compute node. In the Actions column, select Remote Control. Note: The user ID that you use to log in to IBM Flex System Manager management software must have sufficient user permissions to manage the compute node.
  • Page 53: Typical Operating-System Installation

    If you have already configured the compute node hardware and you are not using the ServerGuide program to install your operating system, you can download operating-system installation instructions for the compute node from http://www.ibm.com/supportportal/. Chapter 3. Installing the operating system...
  • Page 54: Using Ibm Serverguide Scripting Toolkit

    Scripting Toolkit is used with IBM ServerGuide, it provides a total solution for deploying IBM Flex System compute nodes in an unattended mode. For more information about using the IBM ServerGuide Scripting Toolkit, see http://www.ibm.com/support/entry/portal/docdisplay?lndocid=TOOL-CENTER. IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 55: Chapter 4. Accessing The Imm2

    The IMM2 is a second generation of the functions that were formerly provided by the baseboard management controller hardware. It combines service processor functions, video controller, and remote presence function in a single chip. For more information about the IMM2, seehttp://www.ibm.com/support/entry/ portal/docdisplay?Indocid=MIGR-5089484 Accessing the IMM2 remotely...
  • Page 56: Logging In To The Web Interface

    IMM web interface. Beneath the title bar are tabs that allow you to access various IMM2 functions, as listed in Table 2 on page 45. For more information about the IMM2 actions, see IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 57 The Download Service Data page creates a compressed file of Support Data information that can be used by IBM Support to assist you. You might be asked to generate this file and send to IBM when requesting service. Server Management Server Firmware The Server Firmware page displays firmware levels and allows you to update the IMM2 firmware, compute node firmware, and DSA firmware.
  • Page 58 IMM2. Global login settings include enabling Lightweight Directory Access Protocol (LDAP) compute node authentication, setting the web inactivity timeout, and customizing the account security settings. IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 59 Table 2. IMM2 actions (continued) Selection Description IMM Management Network The Network Protocol Properties page provides access to networking properties, status, and settings for your IMM2: v The Ethernet tab manages how the IMM2 communicates using Ethernet. v The SNMP tab configures the SNMPv1 and SNMPv3 agents. v The DNS tab configures the DNS servers that the IMM2 interacts with.
  • Page 60: Accessing The Imm2 Using The Lan Over Usb Interface

    Note: You can use the -x path command-line interface option to extract the files. For more information about this option, see the readme file that comes with the update package. IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 61: Potential Conflicts With The Lan Over Usb Interface

    Hardware Wizard, click Finish. A new local area connection appears. If the message This connection has limited or no connectivity is displayed, ignore this message. 10. Return to the Device Manager. IBM USB Remote NDIS Network Device appears under Network Adapters. Installing the LAN over USB Linux device driver Versions of Linux since RHEL5 Update 3 and SLES10 Service Pack 2 support the LAN over USB interface by default.
  • Page 62: Resolving Conflicts With The Imm2 Lan Over Usb Interface

    Compute Nodes. 3. Click the compute node ID. 4. Click the General tab. 5. Uncheck Enable Ethernet Over USB to disable the LAN over USB interface. IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 63: Chapter 5. Parts Listing, Types 7917 And 2584

    Structural parts: Purchase and replacement of structural parts (components such as the top cover and bezel) is your responsibility. If IBM acquires or installs a structural part at your request, you will be charged for the installation.
  • Page 64 Intel Xeon Processor E5-4640, 8C 2.4 GHz 20 MB Cache 1600 MHz 95W 90Y9056 Intel Xeon Processor E5-4650, 8C 2.7 GHz 20 MB Cache 1600 MHz 130W 69Y3119 (Type 7917, models F2x, F4x) IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 65 Hard disk drive backplane, SAS single 2.5 inch (Type 2584, models C2x, 88Y6246 C4x) (Type 7917, models A2x, A4x, B2x, B4x, C2x, C4x, D2x, D4x, F2x, F4x) IBM Flex System console breakout cable (models AC1, MC1, CTO) 81Y5287 Label kit 00D6313...
  • Page 66 2. From the Products menu, select Upgrades, accessories & parts. 3. Click Obtain maintenance parts; then, follow the instructions to order the part from the retail store. IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 67 If you need help with your order, call the toll-free number that is listed on the retail parts page, or contact your local IBM representative for assistance. Chapter 5. Parts listing, Types 7917 and 2584...
  • Page 68 IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 69: Chapter 6. Troubleshooting

    Service bulletins IBM continually updates the support website with tips and techniques that you can use to solve problems that you might have with the IBM Flex System x440 Compute Node. To find service bulletins that are available for the IBM Flex System x440 Compute Node, go to http://www.ibm.com/supportportal/ and search for the terms 7917 or...
  • Page 70 The following illustration shows the LEDs on the light path diagnostics panel. The following illustration shows the locations of the light path diagnostics LEDs on the system board. IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 71 DIMM DIMM Microprocessor 3 Microprocessor 1 error error error error Storage backplane 1 error DIMM DIMM error error Storage backplane 2 error Battery error DIMM DIMM Microprocessor 4 Microprocessor 2 error error error error Light path diagnostics LEDs Use this information to diagnose possible errors that are indicated by the light path diagnostics LEDs.
  • Page 72 DIMM” on page 502) Light path diagnostics LED System board light path Check for error LEDs that diagnostics LEDs have are lit on the system board power. assembly. IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 73 Table 5. Light path LED errors (continued) Light path diagnostics LED Description Action Microprocessor x error The microprocessor has 1. Check the CMM log for failed, or overheated, or the more information. boot microprocessor is Perform the appropriate missing. action. 2.
  • Page 74 1 is connected to the network. DLLUP11 Green Ethernet 1-1 link This LED lights when port 1 on LOM controller 1 is connected to the network. IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 75: Imm Event Log

    Table 6. System board diagnostic LED information (continued) Color LED name Description DLLUP20 Green Ethernet 2-0 link This LED lights when port 0 on LOM controller 2 is connected to the network. DLLUP21 Green Ethernet 2-1 link This LED lights when port 1 on LOM controller 2 is connected to the network.
  • Page 76 (as the IPMI event log), the operating-system event logs, or the merged DSA log. You can also use DSA Preboot to view these logs, although you IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 77: Ibm Dynamic System Analysis Preboot Diagnostic Program

    2. Click Linux. 3. Click the Linux blueprints tab. 4. Click Blueprints for Linux on IBM systems, and then click Using Intelligent Platform Management Interface (IPMI) on IBM Linux platforms. The following table describes the methods that you can use to view the event logs, depending on the condition of the compute node.
  • Page 78 A diagnostic text message contains one of the following results: v Passed: The test was completed without any errors. v Failed: The test detected an error. IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 79: Event Messages

    In the DSA GUI, select DSA Error Log from the System Information page. You can send the DSA error log file to IBM Support to aid in diagnosing the compute node problems, or you can use the DSA CLI copy command to copy the log to an external USB device.
  • Page 80 While you wait for IBM Support to call, you can perform the recommended actions for the event. User response The actions that you should perform to solve the event. IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 81 Perform the steps listed in this section in the order shown until the problem is solved. After you perform all of the actions that are described in this field, if you cannot solve the problem, contact IBM Support. Note: This list includes error codes and messages that might not apply to this machine type and model.
  • Page 82 Explanation: The specified user has enabled or disabled the Ethernet interface. May also be shown as 4000000700000000 or 0x4000000700000000 Severity: Info Alert Category: none Serviceable: No IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 83 40000008-00000000 • 4000000a-00000000 CIM Information: Prefix: IMM and ID: 0007 SNMP Trap ID: Automatically notify Support: No User response: Information only; no action is required. 40000008-00000000 Hostname set to [arg1] by user [arg2]. Explanation: The specified user has changed the Integrated Management Module host name. May also be shown as 4000000800000000 or 0x4000000800000000 Severity: Info Alert Category: System - IMM Network event...
  • Page 84 Explanation: The specified user has logged in to the Integrated Management Module. May also be shown as 4000000e00000000 or 0x4000000e00000000 Severity: Info Alert Category: System - Remote Login IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 85 4000000f-00000000 • 40000011-00000000 Serviceable: No CIM Information: Prefix: IMM and ID: 0014 SNMP Trap ID: 30 Automatically notify Support: No User response: Information only; no action is required. 4000000f-00000000 Attempting to [arg1] server [arg2] by user [arg3]. Explanation: This message is for the use case where a user is using the Management Controller to perform a power function on the system.
  • Page 86 Alert Category: none Serviceable: No CIM Information: Prefix: IMM and ID: 0020 SNMP Trap ID: Automatically notify Support: No User response: Information only; no action is required. IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 87 40000015-00000000 • 40000018-00000000 40000015-00000000 Management Controller [arg1] reset was initiated by user [arg2]. Explanation: The Integrated Management Module has been reset. The logs provide additional details. May also be shown as 4000001500000000 or 0x4000001500000000 Severity: Info Alert Category: none Serviceable: No CIM Information: Prefix: IMM and ID: 0021 SNMP Trap ID: Automatically notify Support: No...
  • Page 88 Alert Category: none Serviceable: No CIM Information: Prefix: IMM and ID: 0027 SNMP Trap ID: Automatically notify Support: No User response: Information only; no action is required. IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 89 4000001c-00000000 • 4000001e-00000000 4000001c-00000000 Watchdog [arg1] Screen Capture Occurred. Explanation: An operating-system error has occurred, and the screen capture was successful. May also be shown as 4000001c00000000 or 0x4000001c00000000 Severity: Info Alert Category: System - other Serviceable: No CIM Information: Prefix: IMM and ID: 0028 SNMP Trap ID: 22 Automatically notify Support: No User response: If there was no operating-system error, complete the following steps until the problem is solved:...
  • Page 90 Alert Category: none Serviceable: No CIM Information: Prefix: IMM and ID: 0033 SNMP Trap ID: Automatically notify Support: No User response: Information only; no action is required. IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 91 40000022-00000000 • 40000025-00000000 40000022-00000000 SSL data in the Management Controller [arg1] configuration data is invalid. Clearing configuration data region and disabling SSL. Explanation: There is a problem with the certificate that has been imported into the IMM. The imported certificate must contain a public key that corresponds to the key pair that was previously generated through the “Generate a New Key and Certificate Signing Request ”...
  • Page 92 Explanation: The Integrated Management Module has sent a test message to help verify connectivity. May also be shown as 4000002800000000 or 0x4000002800000000 Severity: Info Alert Category: System - other Serviceable: No IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 93 40000029-00000000 • 4000002b-00000000 CIM Information: Prefix: IMM and ID: 0040 SNMP Trap ID: 22 Automatically notify Support: No User response: Information only; no action is required. 40000029-00000000 Security: Userid: [arg1] had [arg2] login failures from an SSH client at IP address [arg3]. Explanation: A user has exceeded the maximum allowed number of unsuccessful login attempts from SSH and has been prevented from logging in for the lockout period.
  • Page 94 Explanation: The specified user has enabled IPv6 support on the Integrated Management Module. May also be shown as 4000002f00000000 or 0x4000002f00000000 Severity: Info Alert Category: none Serviceable: No CIM Information: Prefix: IMM and ID: 0047 IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 95 40000030-00000000 • 40000033-00000000 SNMP Trap ID: Automatically notify Support: No User response: Information only; no action is required. 40000030-00000000 IPv6 disabled by user [arg1] . Explanation: The specified user has disabled IPv6 support on the Integrated Management Module. May also be shown as 4000003000000000 or 0x4000003000000000 Severity: Info Alert Category: none Serviceable: No...
  • Page 96 Alert Category: none Serviceable: No CIM Information: Prefix: IMM and ID: 0054 SNMP Trap ID: Automatically notify Support: No User response: Information only; no action is required. IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 97 40000037-00000000 • 4000003a-00000000 40000037-00000000 ENET[[arg1]] IPv6-LinkLocal:HstName=[arg2], IP@=[arg3], Pref=[arg4] . Explanation: The IPv6 link-local address is active. May also be shown as 4000003700000000 or 0x4000003700000000 Severity: Info Alert Category: none Serviceable: No CIM Information: Prefix: IMM and ID: 0055 SNMP Trap ID: Automatically notify Support: No User response: Information only;...
  • Page 98 May also be shown as 4000003d00000000 or 0x4000003d00000000 Severity: Info Alert Category: none Serviceable: No CIM Information: Prefix: IMM and ID: 0061 SNMP Trap ID: Automatically notify Support: No IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 99 4000003e-00000000 • 40000041-00000000 User response: Information only; no action is required. 4000003e-00000000 SSH port number changed from [arg1] to [arg2] by user [arg3]. Explanation: The specified user has changed the Secure Shell (SSH) port number. May also be shown as 4000003e00000000 or 0x4000003e00000000 Severity: Info Alert Category: none Serviceable: No...
  • Page 100 Alert Category: none Serviceable: No CIM Information: Prefix: IMM and ID: 0068 SNMP Trap ID: Automatically notify Support: No User response: Information only; no action is required. IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 101 40000045-00000000 • 40000048-00000000 40000045-00000000 Syslog port number changed from [arg1] to [arg2] by user [arg3]. Explanation: A user has modified the Syslog receiver port number May also be shown as 4000004500000000 or 0x4000004500000000 Severity: Info Alert Category: none Serviceable: No CIM Information: Prefix: IMM and ID: 0069 SNMP Trap ID: Automatically notify Support: No...
  • Page 102 LDAP Server configuration set by user [arg1]: SelectionMethod=[arg2], DomainName=[arg3], Server1=[arg4], Server2=[arg5], Server3=[arg6], Server4=[arg7]. Explanation: A user changed the LDAP server configuration May also be shown as 4000004c00000000 or 0x4000004c00000000 IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 103 4000004d-00000000 • 4000004f-00000000 Severity: Info Alert Category: none Serviceable: No CIM Information: Prefix: IMM and ID: 0076 SNMP Trap ID: Automatically notify Support: No User response: Information only; no action is required. 4000004d-00000000 LDAP set by user [arg1]: RootDN=[arg2], UIDSearchAttribute=[arg3], BindingMethod=[arg4], EnhancedRBS=[arg5], TargetName=[arg6], GroupFilter=[arg7], GroupAttribute=[arg8], LoginAttribute=[arg9].
  • Page 104 Server [arg1] scheduled for every [arg2] at [arg3] by user [arg4]. Explanation: A user configured a recurring Server Power Action May also be shown as 4000005300000000 or 0x4000005300000000 Severity: Info IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 105 40000054-00000000 • 40000056-00000000 Alert Category: none Serviceable: No CIM Information: Prefix: IMM and ID: 0083 SNMP Trap ID: Automatically notify Support: No User response: Information only; no action is required. 40000054-00000000 Server [arg1] [arg2] cleared by user [arg3]. Explanation: A user cleared a Server Power Action. May also be shown as 4000005400000000 or 0x4000005400000000 Severity: Info Alert Category: none...
  • Page 106 LAN over USB Port Forwarding set by user [arg1]: ExternalPort=[arg2], USB-LAN port=[arg3]. Explanation: A user configured USB-LAN port forwarding May also be shown as 4000005a00000000 or 0x4000005a00000000 Severity: Info Alert Category: none Serviceable: No IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 107 4000005b-00000000 • 4000005d-00000000 CIM Information: Prefix: IMM and ID: 0090 SNMP Trap ID: Automatically notify Support: No User response: Information only; no action is required. 4000005b-00000000 Secure Web services (HTTPS) [arg1] by user [arg2]. Explanation: A user enables or disables Secure web services May also be shown as 4000005b00000000 or 0x4000005b00000000 Severity: Info Alert Category: none...
  • Page 108 Explanation: The specified user has removed an Integrated Management Module license. Access to the specified feature is no longer allowed. May also be shown as 4000006100000000 or 0x4000006100000000 Severity: Info Alert Category: none Serviceable: No IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 109 40000062-00000000 • 40000064-00000000 CIM Information: Prefix: IMM and ID: 0097 SNMP Trap ID: Automatically notify Support: No User response: Information only; no action is required. 40000062-00000000 Global Login General Settings set by user [arg1]: AuthenticationMethod=[arg2], LockoutPeriod=[arg3], SessionTimeout=[arg4]. Explanation: A user changes the Global Login General Settings May also be shown as 4000006200000000 or 0x4000006200000000 Severity: Info Alert Category: none...
  • Page 110 Explanation: User account priveleges assigned May also be shown as 4000006800000000 or 0x4000006800000000 Severity: Info Alert Category: none Serviceable: No CIM Information: Prefix: IMM and ID: 0104 IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 111 40000069-00000000 • 4000006c-00000000 SNMP Trap ID: Automatically notify Support: No User response: Information only; no action is required. 40000069-00000000 User [arg1] for SNMPv3 set: AuthenticationProtocol=[arg2], PrivacyProtocol=[arg3], AccessType=[arg4], HostforTraps=[arg5]. Explanation: User account SNMPv3 settings changed May also be shown as 4000006900000000 or 0x4000006900000000 Severity: Info Alert Category: none Serviceable: No...
  • Page 112 May also be shown as 4000006f00000000 or 0x4000006f00000000 Severity: Info Alert Category: none Serviceable: No CIM Information: Prefix: IMM and ID: 0111 SNMP Trap ID: Automatically notify Support: No IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 113 40000070-00000000 • 40000073-00000000 User response: Information only; no action is required. 40000070-00000000 SNMP Traps enabled by user [arg1]: EnabledAlerts=[arg2], AllowedFilters=[arg3] . Explanation: The specified user has enabled Simple Network Management Protocol (SNMP) traps. May also be shown as 4000007000000000 or 0x4000007000000000 Severity: Info Alert Category: none Serviceable: No...
  • Page 114 SNMP Trap ID: 164 Automatically notify Support: No User response: User may need to adjust the power cap value to be greater or equal to the minimum power cap. IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 115 40000077-00000000 • 4000007a-00000000 40000077-00000000 Power capping was activated by user [arg1]. Explanation: The power capping control has been enabled. May also be shown as 4000007700000000 or 0x4000007700000000 Severity: Info Alert Category: none Serviceable: No CIM Information: Prefix: IMM and ID: 0119 SNMP Trap ID: Automatically notify Support: No User response: Information only;...
  • Page 116 User response: Information only; no action is required. 4000007e-00000000 External throttling occurred . Explanation: External throttling has occurred. May also be shown as 4000007e00000000 or 0x4000007e00000000 Severity: Info IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 117 4000007f-00000000 • 40000082-00000000 Alert Category: none Serviceable: No CIM Information: Prefix: IMM and ID: 0126 SNMP Trap ID: Automatically notify Support: No User response: Information only; no action is required. 4000007f-00000000 Power cap throttling occurred. Explanation: Power cap throttling has occurrred. May also be shown as 4000007f00000000 or 0x4000007f00000000 Severity: Info Alert Category: none...
  • Page 118 Explanation: The specified user has generated a test automatic support notification. May also be shown as 4000008600000000 or 0x4000008600000000 Severity: Info Alert Category: none Serviceable: No IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 119 CIM Information: Prefix: IMM and ID: 0135 SNMP Trap ID: Automatically notify Support: Yes User response: IBM Support will address the problem. 40000088-00000000 Management Controller [arg1]: Configuration restoration from a file by user [arg2] completed. Explanation: The specified user has successfully restored the configuration of the specified management controller from a file.
  • Page 120 If the specified sensor is Planar 12V, check the Chassis Management Module or Flex System Manager event log for power-supply-related issues, and resolve those issues. If the problem remains, replace the system board. IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 121 80010202-2801ffff • 80010b01-3701ffff 80010202-2801ffff Sensor Planar VBAT has detected low battery voltage. Explanation: The CMOS battery voltage has dropped below its specified threshold. May also be shown as 800102022801ffff or 0x800102022801ffff Severity: Error Alert Category: Critical - Voltage Serviceable: Yes CIM Information: Prefix: PLAT and ID: 0480 SNMP Trap ID: 1 Automatically notify Support: No...
  • Page 122 User response: This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Information Center for the appropriate user response. IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 123 80070101-0301ffff • 80070101-0303ffff 80070101-0301ffff Sensor CPU 1 Overtemp has transitioned from normal to non-critical state. Explanation: The microprocessor 1 temperature has risen above its specified threshold. May also be shown as 800701010301ffff or 0x800701010301ffff Severity: Warning Alert Category: Warning - Temperature Serviceable: Yes CIM Information: Prefix: PLAT and ID: 0520 SNMP Trap ID: 12...
  • Page 124 May also be shown as 800701012c02ffff or 0x800701012c02ffff Severity: Warning Alert Category: Warning - Temperature Serviceable: Yes CIM Information: Prefix: PLAT and ID: 0520 SNMP Trap ID: 12 Automatically notify Support: No IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 125 80070101-2c03ffff • 80070101-2d01ffff User response: Complete the following steps until the problem is solved: 1. Check the Chassis Management Module or Flex System Manager event log for any fan- or cooling-related issues. 2. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are in place and correctly installed.
  • Page 126 2. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are in place and correctly installed. 3. Make sure that the room temperature is within operating specifications. IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 127 80070114-2201ffff • 8007020f-2201ffff 80070114-2201ffff Sensor [SensorElementName] has transitioned from normal to non-critical state. Explanation: This message is for the use case when an implementation has detected a Sensor transitioned to non-critical from normal. May also be shown as 800701142201ffff or 0x800701142201ffff Severity: Warning Alert Category: Warning - Other Serviceable: Yes...
  • Page 128 May also be shown as 800702172c03ffff or 0x800702172c03ffff Severity: Error Alert Category: Critical - Other Serviceable: Yes CIM Information: Prefix: PLAT and ID: 0522 SNMP Trap ID: 50 Automatically notify Support: No IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 129 8007021b-0301ffff • 8007021b-0303ffff User response: Complete the following steps: 1. Remove any recently installed components. 2. Try to power on the chassis. v If the chassis successfully powers on, complete the following steps: a. Check the ServerProven website to make sure that recently installed components are compatible with the chassis.
  • Page 130 Explanation: The temperature of microprocessor 2 has exceeded its specified threshold, causing a hard shutdown of the compute node. May also be shown as 800703010302ffff or 0x800703010302ffff Severity: Error Alert Category: Critical - Temperature Serviceable: Yes IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 131 80070301-0303ffff • 80070301-0304ffff CIM Information: Prefix: PLAT and ID: 0524 SNMP Trap ID: 0 Automatically notify Support: No User response: Complete the following steps until the problem is solved: 1. Check the Chassis Management Module or Flex System Manager event log for any fan- or cooling-related issues. 2.
  • Page 132 Explanation: The temperature of the I/O expansion adapter in I/O expansion connector 3 has exceeded its specified threshold. The compute node has attempted a soft shutdown. May also be shown as 800703012c03ffff or 0x800703012c03ffff Severity: Error IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 133 80070301-2c04ffff • 80070301-2d01ffff Alert Category: Critical - Temperature Serviceable: Yes CIM Information: Prefix: PLAT and ID: 0524 SNMP Trap ID: 0 Automatically notify Support: No User response: Complete the following steps until the problem is solved: 1. Check the Chassis Management Module or Flex System Manager event log for any fan- or cooling-related issues. 2.
  • Page 134 Alert Category: Warning - Temperature Serviceable: No CIM Information: Prefix: PLAT and ID: 0526 SNMP Trap ID: 12 Automatically notify Support: No User response: Information only; no action is required. IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 135 80070401-2c02ffff • 80070601-2c01ffff 80070401-2c02ffff Sensor Mezz Exp 2 temp has transitioned to non-critical from a more severe state. Explanation: The previously high temperature of the I/O expansion adapter in I/O expansion connector 2 has returned to below its specified threshold. May also be shown as 800704012c02ffff or 0x800704012c02ffff Severity: Warning Alert Category: Warning - Temperature...
  • Page 136 3. Make sure that the room temperature is within operating specifications. 4. If there are no other thermal issues, replace the I/O expansion adapter. IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 137 80070601-2c04ffff • 80070614-2201ffff 80070601-2c04ffff Sensor Mezz Exp 4 temp has transitioned to non-recoverable. Explanation: The temperature of the I/O expansion adapter in I/O expansion connector 4 has exceeded its specified threshold. The compute node has attempted a soft shutdown. May also be shown as 800706012c04ffff or 0x800706012c04ffff Severity: Error Alert Category: Critical - Temperature Serviceable: Yes...
  • Page 138 Explanation: A problem was detected in the I/O expansion adapter in I/O expansion connector 3. The adapter is unable to initialize. May also be shown as 800706172c03ffff or 0x800706172c03ffff Severity: Error IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 139 80070617-2c04ffff • 8008001b-1f07ffff Alert Category: Critical - Other Serviceable: Yes CIM Information: Prefix: PLAT and ID: 0530 SNMP Trap ID: 50 Automatically notify Support: No User response: Complete the following steps: 1. Remove the I/O expansion adapter in I/O expansion connector 3. 2.
  • Page 140 May also be shown as 8008010f2101ffff or 0x8008010f2101ffff Severity: Info Alert Category: System - Other Serviceable: No CIM Information: Prefix: PLAT and ID: 0536 SNMP Trap ID: IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 141 8008011b-1f07ffff • 8008011b-1f08ffff Automatically notify Support: No User response: Information only; no action is required. 8008011b-1f07ffff Device [LogicalDeviceElementName] has been added. Explanation: The fabric connector for LAN On Motherboard (LOM) in location 1 is present. May also be shown as 8008011b1f07ffff or 0x8008011b1f07ffff Severity: Info Alert Category: System - Other Serviceable: No...
  • Page 142 User response: Information only; no action is required. 80090112-2101ffff Device [LogicalDeviceElementName] has been enabled. Explanation: An IPMI or SNMP Account has been enabled. May also be shown as 800901122101ffff or 0x800901122101ffff Severity: Info IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 143 800b010c-2581ffff • 800b050c-2581ffff Alert Category: System - Other Serviceable: No CIM Information: Prefix: PLAT and ID: 0538 SNMP Trap ID: Automatically notify Support: No User response: Information only; no action is required. 800b010c-2581ffff Redundancy Lost for [RedundancySetElementName] has asserted. Explanation: This message is for the use case when Redundancy Lost has asserted. May also be shown as 800b010c2581ffff or 0x800b010c2581ffff Severity: Error Alert Category: Critical - Memory...
  • Page 144 May also be shown as 806f00070303ffff or 0x806f00070303ffff Severity: Error Alert Category: Critical - CPU Serviceable: Yes CIM Information: Prefix: PLAT and ID: 0042 SNMP Trap ID: 40 Automatically notify Support: No IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 145 806f0007-0304ffff • 806f0009-0701ffff User response: This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Information Center for the appropriate user response.
  • Page 146 May also be shown as 806f000d0403ffff or 0x806f000d0403ffff Severity: Info Alert Category: Critical - Hard Disk drive Serviceable: No CIM Information: Prefix: PLAT and ID: 0162 IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 147 806f000d-0404ffff • 806f000d-0407ffff SNMP Trap ID: 5 Automatically notify Support: No User response: Information only; no action is required. 806f000d-0404ffff The Drive Drive 4 has been added. Explanation: Hard disk drive 4 has been installed. May also be shown as 806f000d0404ffff or 0x806f000d0404ffff Severity: Info Alert Category: Critical - Hard Disk drive Serviceable: No...
  • Page 148 May also be shown as 806f000f220103ff or 0x806f000f220103ff Severity: Error Alert Category: Critical - Hard Disk drive Serviceable: Yes CIM Information: Prefix: PLAT and ID: 0770 IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 149 806f000f-220104ff • 806f000f-22010aff SNMP Trap ID: 5 Automatically notify Support: No User response: ABR Status : Firmware Error : This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Information Center for the appropriate user response.
  • Page 150 May also be shown as 806f000f2201ffff or 0x806f000f2201ffff Severity: Error Alert Category: Critical - Other Serviceable: Yes CIM Information: Prefix: PLAT and ID: 0184 SNMP Trap ID: 50 Automatically notify Support: No IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 151 806f0013-1701ffff • 806f0021-2582ffff User response: This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Information Center for the appropriate user response.
  • Page 152 2. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are in place and correctly installed. 3. Make sure that the room temperature is within operating specifications. IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 153 806f0107-0302ffff • 806f0107-0303ffff 4. Make sure that the microprocessor 1 heat sink is securely installed. 5. Make sure that the microprocessor 1 heat sink is installed correctly and the thermal material is correctly applied. 6. Replace microprocessor 1. 806f0107-0302ffff An over-temperature condition has been detected on [ProcessorElementName]. Explanation: The temperature of microprocessor 2 has exceeded the critical level, causing a hard shutdown of the compute node.
  • Page 154 Explanation: The compute node has been powered off and powered on. May also be shown as 806f01090701ffff or 0x806f01090701ffff Severity: Info Alert Category: System - Other Serviceable: No IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 155 806f010c-2001ffff • 806f010c-2003ffff CIM Information: Prefix: PLAT and ID: 0108 SNMP Trap ID: Automatically notify Support: No User response: Information only; no action is required. 806f010c-2001ffff Uncorrectable error detected for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. Explanation: This message is for the use case when an implementation has detected a Memory uncorrectable error. May also be shown as 806f010c2001ffff or 0x806f010c2001ffff Severity: Error Alert Category: Critical - Memory...
  • Page 156 User response: This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Information Center for the appropriate user response. IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 157 806f010c-2007ffff • 806f010c-2009ffff 806f010c-2007ffff Uncorrectable error detected for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. Explanation: This message is for the use case when an implementation has detected a Memory uncorrectable error. May also be shown as 806f010c2007ffff or 0x806f010c2007ffff Severity: Error Alert Category: Critical - Memory Serviceable: Yes CIM Information: Prefix: PLAT and ID: 0138 SNMP Trap ID: 41...
  • Page 158 User response: This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Information Center for the appropriate user response. IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 159 806f010c-200dffff • 806f010c-200fffff 806f010c-200dffff Uncorrectable error detected for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. Explanation: This message is for the use case when an implementation has detected a Memory uncorrectable error. May also be shown as 806f010c200dffff or 0x806f010c200dffff Severity: Error Alert Category: Critical - Memory Serviceable: Yes CIM Information: Prefix: PLAT and ID: 0138 SNMP Trap ID: 41...
  • Page 160 User response: This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Information Center for the appropriate user response. IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 161 806f010c-2013ffff • 806f010c-2015ffff 806f010c-2013ffff Uncorrectable error detected for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. Explanation: This message is for the use case when an implementation has detected a Memory uncorrectable error. May also be shown as 806f010c2013ffff or 0x806f010c2013ffff Severity: Error Alert Category: Critical - Memory Serviceable: Yes CIM Information: Prefix: PLAT and ID: 0138 SNMP Trap ID: 41...
  • Page 162 User response: This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Information Center for the appropriate user response. IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 163 806f010c-2019ffff • 806f010c-201bffff 806f010c-2019ffff Uncorrectable error detected for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. Explanation: This message is for the use case when an implementation has detected a Memory uncorrectable error. May also be shown as 806f010c2019ffff or 0x806f010c2019ffff Severity: Error Alert Category: Critical - Memory Serviceable: Yes CIM Information: Prefix: PLAT and ID: 0138 SNMP Trap ID: 41...
  • Page 164 User response: This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Information Center for the appropriate user response. IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 165 806f010c-201fffff • 806f010c-2021ffff 806f010c-201fffff Uncorrectable error detected for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. Explanation: This message is for the use case when an implementation has detected a Memory uncorrectable error. May also be shown as 806f010c201fffff or 0x806f010c201fffff Severity: Error Alert Category: Critical - Memory Serviceable: Yes CIM Information: Prefix: PLAT and ID: 0138 SNMP Trap ID: 41...
  • Page 166 User response: This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Information Center for the appropriate user response. IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 167 806f010c-2025ffff • 806f010c-2027ffff 806f010c-2025ffff Uncorrectable error detected for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. Explanation: This message is for the use case when an implementation has detected a Memory uncorrectable error. May also be shown as 806f010c2025ffff or 0x806f010c2025ffff Severity: Error Alert Category: Critical - Memory Serviceable: Yes CIM Information: Prefix: PLAT and ID: 0138 SNMP Trap ID: 41...
  • Page 168 User response: This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Information Center for the appropriate user response. IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 169 806f010c-202bffff • 806f010c-202dffff 806f010c-202bffff Uncorrectable error detected for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. Explanation: This message is for the use case when an implementation has detected a Memory uncorrectable error. May also be shown as 806f010c202bffff or 0x806f010c202bffff Severity: Error Alert Category: Critical - Memory Serviceable: Yes CIM Information: Prefix: PLAT and ID: 0138 SNMP Trap ID: 41...
  • Page 170 User response: This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Information Center for the appropriate user response. IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 171 806f010c-2581ffff • 806f010d-0401ffff 806f010c-2581ffff Uncorrectable error detected for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. Explanation: This message is for the use case when an implementation has detected a Memory uncorrectable error. All DIMMs. One of the DIMMs. May also be shown as 806f010c2581ffff or 0x806f010c2581ffff Severity: Error Alert Category: Critical - Memory Serviceable: Yes...
  • Page 172 May also be shown as 806f010d0404ffff or 0x806f010d0404ffff Severity: Error Alert Category: Critical - Hard Disk drive Serviceable: Yes CIM Information: Prefix: PLAT and ID: 0164 IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 173 806f010d-0405ffff • 806f010d-0407ffff SNMP Trap ID: 5 Automatically notify Support: Yes User response: Complete the following steps until the problem is solved: 1. Check the Support Portal for service bulletins and RETAIN tips related to your drive. 2. Check the Support Portal for firmware updates related to your drive. 3.
  • Page 174 Explanation: The connections of the SAS cable between the SAS backplane and the planar are not complete. May also be shown as 806f011b1f03ffff or 0x806f011b1f03ffff Severity: Error Alert Category: Critical - Other IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 175 806f011b-1f04ffff • 806f0207-0301ffff Serviceable: Yes CIM Information: Prefix: PLAT and ID: 0266 SNMP Trap ID: 50 Automatically notify Support: Yes User response: 1. Check the connections of the SAS cable between the disk and the backplane 2. (Trained service personnel only). 806f011b-1f04ffff The connector [PhysicalConnectorElementName] has encountered a configuration error.
  • Page 176 User response: This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Information Center for the appropriate user response. IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 177 806f0207-2584ffff • 806f020d-0402ffff 806f0207-2584ffff [ProcessorElementName] has Failed with FRB1/BIST condition. Explanation: This message is for the use case when an implementation has detected a Processor Failed - FRB1/BIST condition. All CPUs. One of CPUs. May also be shown as 806f02072584ffff or 0x806f02072584ffff Severity: Error Alert Category: Critical - CPU Serviceable: Yes...
  • Page 178 CIM Information: Prefix: PLAT and ID: 0168 SNMP Trap ID: 27 Automatically notify Support: Yes User response: Replace the hard disk drive at the next maintenance period. IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 179 806f020d-0406ffff • 806f0225-1f05ffff 806f020d-0406ffff Failure Predicted on drive [StorageVolumeElementName] for array [ComputerSystemElementName]. Explanation: Failure predicted (PFA) on the hard drive. May also be shown as 806f020d0406ffff or 0x806f020d0406ffff Severity: Warning Alert Category: System - Predicted Failure Serviceable: Yes CIM Information: Prefix: PLAT and ID: 0168 SNMP Trap ID: 27 Automatically notify Support: Yes User response: Replace the hard disk drive at the next maintenance period.
  • Page 180 User response: This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Information Center for the appropriate user response. IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 181 806f030c-2003ffff • 806f030c-2006ffff 806f030c-2003ffff Scrub Failure for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. Explanation: Memory error discovered during boot..(not a runtime error). May also be shown as 806f030c2003ffff or 0x806f030c2003ffff Severity: Error Alert Category: Critical - Memory Serviceable: Yes CIM Information: Prefix: PLAT and ID: 0136 SNMP Trap ID: 41 Automatically notify Support: Yes User response: This is a UEFI detected event.
  • Page 182 May also be shown as 806f030c2009ffff or 0x806f030c2009ffff Severity: Error Alert Category: Critical - Memory Serviceable: Yes CIM Information: Prefix: PLAT and ID: 0136 SNMP Trap ID: 41 IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 183 806f030c-200affff • 806f030c-200cffff Automatically notify Support: Yes User response: This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Information Center for the appropriate user response.
  • Page 184 Scrub Failure for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. Explanation: Memory error discovered during boot..(not a runtime error). May also be shown as 806f030c2010ffff or 0x806f030c2010ffff Severity: Error IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 185 806f030c-2011ffff • 806f030c-2013ffff Alert Category: Critical - Memory Serviceable: Yes CIM Information: Prefix: PLAT and ID: 0136 SNMP Trap ID: 41 Automatically notify Support: Yes User response: This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text.
  • Page 186 User response: This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Information Center for the appropriate user response. IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 187 806f030c-2017ffff • 806f030c-201affff 806f030c-2017ffff Scrub Failure for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. Explanation: Memory error discovered during boot..(not a runtime error). May also be shown as 806f030c2017ffff or 0x806f030c2017ffff Severity: Error Alert Category: Critical - Memory Serviceable: Yes CIM Information: Prefix: PLAT and ID: 0136 SNMP Trap ID: 41 Automatically notify Support: Yes User response: This is a UEFI detected event.
  • Page 188 May also be shown as 806f030c201dffff or 0x806f030c201dffff Severity: Error Alert Category: Critical - Memory Serviceable: Yes CIM Information: Prefix: PLAT and ID: 0136 SNMP Trap ID: 41 IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 189 806f030c-201effff • 806f030c-2020ffff Automatically notify Support: Yes User response: This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Information Center for the appropriate user response.
  • Page 190 Scrub Failure for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. Explanation: Memory error discovered during boot..(not a runtime error). May also be shown as 806f030c2024ffff or 0x806f030c2024ffff Severity: Error IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 191 806f030c-2025ffff • 806f030c-2027ffff Alert Category: Critical - Memory Serviceable: Yes CIM Information: Prefix: PLAT and ID: 0136 SNMP Trap ID: 41 Automatically notify Support: Yes User response: This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text.
  • Page 192 User response: This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Information Center for the appropriate user response. IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 193 806f030c-202bffff • 806f030c-202effff 806f030c-202bffff Scrub Failure for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. Explanation: Memory error discovered during boot..(not a runtime error). May also be shown as 806f030c202bffff or 0x806f030c202bffff Severity: Error Alert Category: Critical - Memory Serviceable: Yes CIM Information: Prefix: PLAT and ID: 0136 SNMP Trap ID: 41 Automatically notify Support: Yes User response: This is a UEFI detected event.
  • Page 194 May also be shown as 806f030c2581ffff or 0x806f030c2581ffff Severity: Error Alert Category: Critical - Memory Serviceable: Yes CIM Information: Prefix: PLAT and ID: 0136 SNMP Trap ID: 41 IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 195 806f0313-1701ffff • 806f0409-0701ffff Automatically notify Support: Yes User response: This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Information Center for the appropriate user response.
  • Page 196 User response: This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Information Center for the appropriate user response. IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 197 806f040c-2004ffff • 806f040c-2006ffff 806f040c-2004ffff [PhysicalMemoryElementName] Disabled on Subsystem [MemoryElementName]. Explanation: This message is for the use case when an implementation has detected that Memory has been Disabled. May also be shown as 806f040c2004ffff or 0x806f040c2004ffff Severity: Info Alert Category: System - Other Serviceable: No CIM Information: Prefix: PLAT and ID: 0131 SNMP Trap ID:...
  • Page 198 User response: This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Information Center for the appropriate user response. IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 199 806f040c-200affff • 806f040c-200cffff 806f040c-200affff [PhysicalMemoryElementName] Disabled on Subsystem [MemoryElementName]. Explanation: This message is for the use case when an implementation has detected that Memory has been Disabled. May also be shown as 806f040c200affff or 0x806f040c200affff Severity: Info Alert Category: System - Other Serviceable: No CIM Information: Prefix: PLAT and ID: 0131 SNMP Trap ID:...
  • Page 200 User response: This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Information Center for the appropriate user response. IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 201 806f040c-2010ffff • 806f040c-2012ffff 806f040c-2010ffff [PhysicalMemoryElementName] Disabled on Subsystem [MemoryElementName]. Explanation: This message is for the use case when an implementation has detected that Memory has been Disabled. May also be shown as 806f040c2010ffff or 0x806f040c2010ffff Severity: Info Alert Category: System - Other Serviceable: No CIM Information: Prefix: PLAT and ID: 0131 SNMP Trap ID:...
  • Page 202 User response: This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Information Center for the appropriate user response. IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 203 806f040c-2016ffff • 806f040c-2018ffff 806f040c-2016ffff [PhysicalMemoryElementName] Disabled on Subsystem [MemoryElementName]. Explanation: This message is for the use case when an implementation has detected that Memory has been Disabled. May also be shown as 806f040c2016ffff or 0x806f040c2016ffff Severity: Info Alert Category: System - Other Serviceable: No CIM Information: Prefix: PLAT and ID: 0131 SNMP Trap ID:...
  • Page 204 User response: This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Information Center for the appropriate user response. IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 205 806f040c-201cffff • 806f040c-201effff 806f040c-201cffff [PhysicalMemoryElementName] Disabled on Subsystem [MemoryElementName]. Explanation: This message is for the use case when an implementation has detected that Memory has been Disabled. May also be shown as 806f040c201cffff or 0x806f040c201cffff Severity: Info Alert Category: System - Other Serviceable: No CIM Information: Prefix: PLAT and ID: 0131 SNMP Trap ID:...
  • Page 206 User response: This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Information Center for the appropriate user response. IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 207 806f040c-2022ffff • 806f040c-2024ffff 806f040c-2022ffff [PhysicalMemoryElementName] Disabled on Subsystem [MemoryElementName]. Explanation: This message is for the use case when an implementation has detected that Memory has been Disabled. May also be shown as 806f040c2022ffff or 0x806f040c2022ffff Severity: Info Alert Category: System - Other Serviceable: No CIM Information: Prefix: PLAT and ID: 0131 SNMP Trap ID:...
  • Page 208 User response: This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Information Center for the appropriate user response. IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 209 806f040c-2028ffff • 806f040c-202affff 806f040c-2028ffff [PhysicalMemoryElementName] Disabled on Subsystem [MemoryElementName]. Explanation: This message is for the use case when an implementation has detected that Memory has been Disabled. May also be shown as 806f040c2028ffff or 0x806f040c2028ffff Severity: Info Alert Category: System - Other Serviceable: No CIM Information: Prefix: PLAT and ID: 0131 SNMP Trap ID:...
  • Page 210 User response: This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Information Center for the appropriate user response. IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 211 806f040c-202effff • 806f040c-2030ffff 806f040c-202effff [PhysicalMemoryElementName] Disabled on Subsystem [MemoryElementName]. Explanation: This message is for the use case when an implementation has detected that Memory has been Disabled. May also be shown as 806f040c202effff or 0x806f040c202effff Severity: Info Alert Category: System - Other Serviceable: No CIM Information: Prefix: PLAT and ID: 0131 SNMP Trap ID:...
  • Page 212 User response: This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Information Center for the appropriate user response. IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 213 806f0507-0302ffff • 806f0507-0304ffff 806f0507-0302ffff CPU 2 has a Configuration Mismatch. Explanation: This message is for the use case when an implementation has detected a Processor Configuration Mismatch has occurred. May also be shown as 806f05070302ffff or 0x806f05070302ffff Severity: Error Alert Category: Critical - CPU Serviceable: Yes CIM Information: Prefix: PLAT and ID: 0062 SNMP Trap ID: 40...
  • Page 214 User response: This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Information Center for the appropriate user response. IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 215 806f050c-2003ffff • 806f050c-2005ffff 806f050c-2003ffff Memory Logging Limit Reached for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. Explanation: This message is for the use case when an implementation has detected that the Memory Logging Limit has been Reached. May also be shown as 806f050c2003ffff or 0x806f050c2003ffff Severity: Warning Alert Category: Critical - Memory Serviceable: Yes...
  • Page 216 User response: This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Information Center for the appropriate user response. IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 217 806f050c-2009ffff • 806f050c-200bffff 806f050c-2009ffff Memory Logging Limit Reached for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. Explanation: This message is for the use case when an implementation has detected that the Memory Logging Limit has been Reached. May also be shown as 806f050c2009ffff or 0x806f050c2009ffff Severity: Warning Alert Category: Critical - Memory Serviceable: Yes...
  • Page 218 User response: This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Information Center for the appropriate user response. IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 219 806f050c-200fffff • 806f050c-2011ffff 806f050c-200fffff Memory Logging Limit Reached for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. Explanation: This message is for the use case when an implementation has detected that the Memory Logging Limit has been Reached. May also be shown as 806f050c200fffff or 0x806f050c200fffff Severity: Warning Alert Category: Critical - Memory Serviceable: Yes...
  • Page 220 User response: This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Information Center for the appropriate user response. IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 221 806f050c-2015ffff • 806f050c-2017ffff 806f050c-2015ffff Memory Logging Limit Reached for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. Explanation: This message is for the use case when an implementation has detected that the Memory Logging Limit has been Reached. May also be shown as 806f050c2015ffff or 0x806f050c2015ffff Severity: Warning Alert Category: Critical - Memory Serviceable: Yes...
  • Page 222 User response: This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Information Center for the appropriate user response. IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 223 806f050c-201bffff • 806f050c-201dffff 806f050c-201bffff Memory Logging Limit Reached for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. Explanation: This message is for the use case when an implementation has detected that the Memory Logging Limit has been Reached. May also be shown as 806f050c201bffff or 0x806f050c201bffff Severity: Warning Alert Category: Critical - Memory Serviceable: Yes...
  • Page 224 User response: This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Information Center for the appropriate user response. IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 225 806f050c-2021ffff • 806f050c-2023ffff 806f050c-2021ffff Memory Logging Limit Reached for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. Explanation: This message is for the use case when an implementation has detected that the Memory Logging Limit has been Reached. May also be shown as 806f050c2021ffff or 0x806f050c2021ffff Severity: Warning Alert Category: Critical - Memory Serviceable: Yes...
  • Page 226 User response: This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Information Center for the appropriate user response. IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 227 806f050c-2027ffff • 806f050c-2029ffff 806f050c-2027ffff Memory Logging Limit Reached for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. Explanation: This message is for the use case when an implementation has detected that the Memory Logging Limit has been Reached. May also be shown as 806f050c2027ffff or 0x806f050c2027ffff Severity: Warning Alert Category: Critical - Memory Serviceable: Yes...
  • Page 228 User response: This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Information Center for the appropriate user response. IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 229 806f050c-202dffff • 806f050c-202fffff 806f050c-202dffff Memory Logging Limit Reached for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. Explanation: This message is for the use case when an implementation has detected that the Memory Logging Limit has been Reached. May also be shown as 806f050c202dffff or 0x806f050c202dffff Severity: Warning Alert Category: Critical - Memory Serviceable: Yes...
  • Page 230 CIM Information: Prefix: PLAT and ID: 0174 SNMP Trap ID: 5 Automatically notify Support: No User response: Replace the hard disk drive that is indicated by a lit status LED. IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 231 806f050d-0401ffff • 806f050d-0404ffff 806f050d-0401ffff Array [ComputerSystemElementName] is in critical condition. Explanation: The RAID array is in critical condition. Immediate action is required to avoid a system outage. May also be shown as 806f050d0401ffff or 0x806f050d0401ffff Severity: Error Alert Category: Critical - Hard Disk drive Serviceable: Yes CIM Information: Prefix: PLAT and ID: 0174 SNMP Trap ID: 5...
  • Page 232 Explanation: IMM has detected a PCI System Error (SERR) on one of these sensors: All PCI Error, One of PCI Error, or PCIs May also be shown as 806f05132582ffff or 0x806f05132582ffff IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 233 806f052b-2101ffff • 806f0607-0302ffff Severity: Error Alert Category: Critical - Other Serviceable: Yes CIM Information: Prefix: PLAT and ID: 0234 SNMP Trap ID: 50 Automatically notify Support: No User response: This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text.
  • Page 234 User response: This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Information Center for the appropriate user response. IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 235 806f060d-0400ffff • 806f060d-0402ffff 806f060d-0400ffff Array [ComputerSystemElementName] has failed. Explanation: The Drive 0 is part of an RAID array that is in the failed condition. To identify drives in the failed array all member drives will report this message. May also be shown as 806f060d0400ffff or 0x806f060d0400ffff Severity: Error Alert Category: Critical - Hard Disk drive Serviceable: Yes...
  • Page 236 Severity: Error Alert Category: Critical - Hard Disk drive Serviceable: Yes CIM Information: Prefix: PLAT and ID: 0176 SNMP Trap ID: 5 Automatically notify Support: Yes IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 237 806f060d-0406ffff • 806f070c-2001ffff User response: v Replace the hard disk drives that are indicated by a lit status LED on the drive. v Recreate the array. v Restore data from backup. 806f060d-0406ffff Array [ComputerSystemElementName] has failed. Explanation: The Drive 6 is part of an RAID array that is in the failed condition. To identify drives in the failed array all member drives will report this message.
  • Page 238 May also be shown as 806f070c2004ffff or 0x806f070c2004ffff Severity: Error Alert Category: Critical - Memory Serviceable: Yes CIM Information: Prefix: PLAT and ID: 0126 IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 239 806f070c-2005ffff • 806f070c-2007ffff SNMP Trap ID: 41 Automatically notify Support: No User response: This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Information Center for the appropriate user response.
  • Page 240 May also be shown as 806f070c200affff or 0x806f070c200affff Severity: Error Alert Category: Critical - Memory Serviceable: Yes CIM Information: Prefix: PLAT and ID: 0126 IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 241 806f070c-200bffff • 806f070c-200dffff SNMP Trap ID: 41 Automatically notify Support: No User response: This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Information Center for the appropriate user response.
  • Page 242 May also be shown as 806f070c2010ffff or 0x806f070c2010ffff Severity: Error Alert Category: Critical - Memory Serviceable: Yes CIM Information: Prefix: PLAT and ID: 0126 SNMP Trap ID: 41 Automatically notify Support: No IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 243 806f070c-2011ffff • 806f070c-2013ffff User response: This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Information Center for the appropriate user response.
  • Page 244 SNMP Trap ID: 41 Automatically notify Support: No User response: This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 245 806f070c-2017ffff • 806f070c-2019ffff IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Information Center for the appropriate user response. 806f070c-2017ffff Configuration Error for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. Explanation: This message is for the use case when an implementation has detected a Memory DIMM configuration error has been corrected.
  • Page 246 SNMP Trap ID: 41 Automatically notify Support: No User response: This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 247 806f070c-201dffff • 806f070c-201fffff IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Information Center for the appropriate user response. 806f070c-201dffff Configuration Error for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. Explanation: This message is for the use case when an implementation has detected a Memory DIMM configuration error has been corrected.
  • Page 248 SNMP Trap ID: 41 Automatically notify Support: No User response: This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 249 806f070c-2023ffff • 806f070c-2025ffff IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Information Center for the appropriate user response. 806f070c-2023ffff Configuration Error for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. Explanation: This message is for the use case when an implementation has detected a Memory DIMM configuration error has been corrected.
  • Page 250 SNMP Trap ID: 41 Automatically notify Support: No User response: This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 251 806f070c-2029ffff • 806f070c-202bffff IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Information Center for the appropriate user response. 806f070c-2029ffff Configuration Error for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. Explanation: This message is for the use case when an implementation has detected a Memory DIMM configuration error has been corrected.
  • Page 252 SNMP Trap ID: 41 Automatically notify Support: No User response: This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 253 806f070c-202fffff • 806f070c-2581ffff IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Information Center for the appropriate user response. 806f070c-202fffff Configuration Error for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. Explanation: This message is for the use case when an implementation has detected a Memory DIMM configuration error has been corrected.
  • Page 254 Explanation: The array that contains Drive 3 is in the process of being rebuilt. May also be shown as 806f070d0403ffff or 0x806f070d0403ffff Severity: Info Alert Category: System - Other IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 255 806f070d-0404ffff • 806f070d-0406ffff Serviceable: No CIM Information: Prefix: PLAT and ID: 0178 SNMP Trap ID: Automatically notify Support: No User response: Information only; no action is required. 806f070d-0404ffff Rebuild in progress for Array in system [ComputerSystemElementName]. Explanation: The array that contains Drive 4 is in the process of being rebuilt. May also be shown as 806f070d0404ffff or 0x806f070d0404ffff Severity: Info Alert Category: System - Other...
  • Page 256 Explanation: This message is for the use case when an implementation has detected a Processor has been Disabled. May also be shown as 806f08070303ffff or 0x806f08070303ffff Severity: Info Alert Category: System - Other IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 257 806f0807-0304ffff • 806f0813-2581ffff Serviceable: No CIM Information: Prefix: PLAT and ID: 0061 SNMP Trap ID: Automatically notify Support: No User response: This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text.
  • Page 258 2. Make sure that all I/O expansion adapters have correct and matching levels of device drivers and firmware. 3. Check the system-event log for additional information about failing components. 4. If there are no entries related to the error in the system-event log, contact IBM Support and send DSA data to IBM.
  • Page 259 806f090c-2002ffff • 806f090c-2003ffff SNMP Trap ID: 22 Automatically notify Support: No User response: Complete the following steps: 1. Check the CMM or FSM event log for any fan or cooling related issues. 2. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are in place and correctly installed.
  • Page 260 May also be shown as 806f090c2006ffff or 0x806f090c2006ffff Severity: Warning Alert Category: System - Other Serviceable: Yes CIM Information: Prefix: PLAT and ID: 0142 SNMP Trap ID: 22 Automatically notify Support: No IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 261 806f090c-2007ffff • 806f090c-2008ffff User response: Complete the following steps: 1. Check the CMM or FSM event log for any fan or cooling related issues. 2. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are in place and correctly installed.
  • Page 262 May also be shown as 806f090c200bffff or 0x806f090c200bffff Severity: Warning Alert Category: System - Other Serviceable: Yes CIM Information: Prefix: PLAT and ID: 0142 SNMP Trap ID: 22 Automatically notify Support: No IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 263 806f090c-200cffff • 806f090c-200dffff User response: Complete the following steps: 1. Check the CMM or FSM event log for any fan or cooling related issues. 2. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are in place and correctly installed.
  • Page 264 May also be shown as 806f090c2010ffff or 0x806f090c2010ffff Severity: Warning Alert Category: System - Other Serviceable: Yes CIM Information: Prefix: PLAT and ID: 0142 SNMP Trap ID: 22 Automatically notify Support: No IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 265 806f090c-2011ffff • 806f090c-2012ffff User response: Complete the following steps: 1. Check the CMM or FSM event log for any fan or cooling related issues. 2. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are in place and correctly installed.
  • Page 266 May also be shown as 806f090c2015ffff or 0x806f090c2015ffff Severity: Warning Alert Category: System - Other Serviceable: Yes CIM Information: Prefix: PLAT and ID: 0142 SNMP Trap ID: 22 Automatically notify Support: No IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 267 806f090c-2016ffff • 806f090c-2017ffff User response: Complete the following steps: 1. Check the CMM or FSM event log for any fan or cooling related issues. 2. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are in place and correctly installed.
  • Page 268 May also be shown as 806f090c201affff or 0x806f090c201affff Severity: Warning Alert Category: System - Other Serviceable: Yes CIM Information: Prefix: PLAT and ID: 0142 SNMP Trap ID: 22 Automatically notify Support: No IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 269 806f090c-201bffff • 806f090c-201cffff User response: Complete the following steps: 1. Check the CMM or FSM event log for any fan or cooling related issues. 2. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are in place and correctly installed.
  • Page 270 May also be shown as 806f090c201fffff or 0x806f090c201fffff Severity: Warning Alert Category: System - Other Serviceable: Yes CIM Information: Prefix: PLAT and ID: 0142 SNMP Trap ID: 22 Automatically notify Support: No IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 271 806f090c-2020ffff • 806f090c-2021ffff User response: Complete the following steps: 1. Check the CMM or FSM event log for any fan or cooling related issues. 2. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are in place and correctly installed.
  • Page 272 May also be shown as 806f090c2024ffff or 0x806f090c2024ffff Severity: Warning Alert Category: System - Other Serviceable: Yes CIM Information: Prefix: PLAT and ID: 0142 SNMP Trap ID: 22 Automatically notify Support: No IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 273 806f090c-2025ffff • 806f090c-2026ffff User response: Complete the following steps: 1. Check the CMM or FSM event log for any fan or cooling related issues. 2. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are in place and correctly installed.
  • Page 274 May also be shown as 806f090c2029ffff or 0x806f090c2029ffff Severity: Warning Alert Category: System - Other Serviceable: Yes CIM Information: Prefix: PLAT and ID: 0142 SNMP Trap ID: 22 Automatically notify Support: No IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 275 806f090c-202affff • 806f090c-202bffff User response: Complete the following steps: 1. Check the CMM or FSM event log for any fan or cooling related issues. 2. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are in place and correctly installed.
  • Page 276 May also be shown as 806f090c202effff or 0x806f090c202effff Severity: Warning Alert Category: System - Other Serviceable: Yes CIM Information: Prefix: PLAT and ID: 0142 SNMP Trap ID: 22 Automatically notify Support: No IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 277 806f090c-202fffff • 806f090c-2030ffff User response: Complete the following steps: 1. Check the CMM or FSM event log for any fan or cooling related issues. 2. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are in place and correctly installed.
  • Page 278 Alert Category: Warning - CPU Serviceable: Yes CIM Information: Prefix: PLAT and ID: 0038 SNMP Trap ID: 42 Automatically notify Support: No User response: Complete the following steps: IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 279 806f0a07-0303ffff • 806f0a07-2584ffff 1. Check the CMM or FSM event log for any fan- or cooling-related issues or power-related issues.. 2. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are in place and correctly installed.
  • Page 280 4. Make sure that the DIMM baffles are in place. 5. If the problem persists and there are no other DIMMs with the same indication, replace the DIMM. IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 281 806f0a0c-2003ffff • 806f0a0c-2005ffff 806f0a0c-2003ffff An Over-Temperature Condition has been detected on the [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. Explanation: This message is for the use case when an implementation has detected an Over Temperature Condition for Memory that has been Detected. May also be shown as 806f0a0c2003ffff or 0x806f0a0c2003ffff Severity: Error Alert Category: Critical - Temperature Serviceable: Yes...
  • Page 282 SNMP Trap ID: 0 Automatically notify Support: No User response: Complete the following steps: 1. Check the CMM or FSM event log for any fan or cooling related issues. IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 283 806f0a0c-2008ffff • 806f0a0c-2009ffff 2. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are in place and correctly installed. 3. Make sure that the room temperature is within operating specifications. 4.
  • Page 284 Explanation: This message is for the use case when an implementation has detected an Over Temperature Condition for Memory that has been Detected. May also be shown as 806f0a0c200cffff or 0x806f0a0c200cffff Severity: Error Alert Category: Critical - Temperature IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 285 806f0a0c-200dffff • 806f0a0c-200effff Serviceable: Yes CIM Information: Prefix: PLAT and ID: 0146 SNMP Trap ID: 0 Automatically notify Support: No User response: Complete the following steps: 1. Check the CMM or FSM event log for any fan or cooling related issues. 2.
  • Page 286 4. Make sure that the DIMM baffles are in place. 5. If the problem persists and there are no other DIMMs with the same indication, replace the DIMM. IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 287 806f0a0c-2011ffff • 806f0a0c-2013ffff 806f0a0c-2011ffff An Over-Temperature Condition has been detected on the [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. Explanation: This message is for the use case when an implementation has detected an Over Temperature Condition for Memory that has been Detected. May also be shown as 806f0a0c2011ffff or 0x806f0a0c2011ffff Severity: Error Alert Category: Critical - Temperature Serviceable: Yes...
  • Page 288 SNMP Trap ID: 0 Automatically notify Support: No User response: Complete the following steps: 1. Check the CMM or FSM event log for any fan or cooling related issues. IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 289 806f0a0c-2016ffff • 806f0a0c-2017ffff 2. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are in place and correctly installed. 3. Make sure that the room temperature is within operating specifications. 4.
  • Page 290 Explanation: This message is for the use case when an implementation has detected an Over Temperature Condition for Memory that has been Detected. May also be shown as 806f0a0c201affff or 0x806f0a0c201affff Severity: Error Alert Category: Critical - Temperature IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 291 806f0a0c-201bffff • 806f0a0c-201cffff Serviceable: Yes CIM Information: Prefix: PLAT and ID: 0146 SNMP Trap ID: 0 Automatically notify Support: No User response: Complete the following steps: 1. Check the CMM or FSM event log for any fan or cooling related issues. 2.
  • Page 292 4. Make sure that the DIMM baffles are in place. 5. If the problem persists and there are no other DIMMs with the same indication, replace the DIMM. IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 293 806f0a0c-201fffff • 806f0a0c-2021ffff 806f0a0c-201fffff An Over-Temperature Condition has been detected on the [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. Explanation: This message is for the use case when an implementation has detected an Over Temperature Condition for Memory that has been Detected. May also be shown as 806f0a0c201fffff or 0x806f0a0c201fffff Severity: Error Alert Category: Critical - Temperature Serviceable: Yes...
  • Page 294 SNMP Trap ID: 0 Automatically notify Support: No User response: Complete the following steps: 1. Check the CMM or FSM event log for any fan or cooling related issues. IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 295 806f0a0c-2024ffff • 806f0a0c-2025ffff 2. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are in place and correctly installed. 3. Make sure that the room temperature is within operating specifications. 4.
  • Page 296 Explanation: This message is for the use case when an implementation has detected an Over Temperature Condition for Memory that has been Detected. May also be shown as 806f0a0c2028ffff or 0x806f0a0c2028ffff Severity: Error Alert Category: Critical - Temperature IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 297 806f0a0c-2029ffff • 806f0a0c-202affff Serviceable: Yes CIM Information: Prefix: PLAT and ID: 0146 SNMP Trap ID: 0 Automatically notify Support: No User response: Complete the following steps: 1. Check the CMM or FSM event log for any fan or cooling related issues. 2.
  • Page 298 4. Make sure that the DIMM baffles are in place. 5. If the problem persists and there are no other DIMMs with the same indication, replace the DIMM. IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 299 806f0a0c-202dffff • 806f0a0c-202fffff 806f0a0c-202dffff An Over-Temperature Condition has been detected on the [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. Explanation: This message is for the use case when an implementation has detected an Over Temperature Condition for Memory that has been Detected. May also be shown as 806f0a0c202dffff or 0x806f0a0c202dffff Severity: Error Alert Category: Critical - Temperature Serviceable: Yes...
  • Page 300 SNMP Trap ID: 0 Automatically notify Support: No User response: Complete the following steps: 1. Check the CMM or FSM event log for any fan or cooling related issues. IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 301 806f0a13-2401ffff • 806f0b13-0701ffff 2. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are in place and correctly installed. 3. Make sure that the room temperature is within operating specifications. 4.
  • Page 302 Alert Category: Critical - Voltage Serviceable: No CIM Information: Prefix: PLAT and ID: 0495 SNMP Trap ID: 1 Automatically notify Support: No User response: Information only; no action is required. IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 303 81010b01-3701ffff • 8103010e-2581ffff 81010b01-3701ffff Numeric sensor [NumericSensorElementName] going high (upper non-recoverable) has deasserted. Explanation: The previously high inlet temperature 1 has returned to below its specified threshold. May also be shown as 81010b013701ffff or 0x81010b013701ffff Severity: Info Alert Category: Critical - Temperature Serviceable: No CIM Information: Prefix: PLAT and ID: 0499 SNMP Trap ID: 0...
  • Page 304 Alert Category: Warning - Temperature Serviceable: No CIM Information: Prefix: PLAT and ID: 0521 SNMP Trap ID: 12 Automatically notify Support: No User response: Information only; no action is required. IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 305 81070101-0304ffff • 81070101-2c03ffff 81070101-0304ffff Sensor CPU 4 Overtemp has deasserted the transition from normal to non-critical state. Explanation: The previously high microprocessor 4 temperature has returned to below its specified threshold. May also be shown as 810701010304ffff or 0x810701010304ffff Severity: Info Alert Category: Warning - Temperature Serviceable: No CIM Information: Prefix: PLAT and ID: 0521...
  • Page 306 Explanation: This message is for the use case when an implementation has detected the Inlet 2 temperature has deasserted a transition to non-critical from normal. May also be shown as 810701013702ffff or 0x810701013702ffff IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 307 81070114-2201ffff • 8107020f-2201ffff Severity: Info Alert Category: Warning - Temperature Serviceable: No CIM Information: Prefix: PLAT and ID: 0521 SNMP Trap ID: 12 Automatically notify Support: No User response: Information only; no action is required. 81070114-2201ffff Sensor TPM Lock has deasserted the transition from normal to non-critical state. Explanation: The TPM Lock has returned to normal.
  • Page 308 Explanation: The I/O Expansion card is no longer in a fault condition. May also be shown as 810702172c02ffff or 0x810702172c02ffff Severity: Info Alert Category: Critical - Other Serviceable: No IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 309 81070217-2c03ffff • 81070219-0701ffff CIM Information: Prefix: PLAT and ID: 0523 SNMP Trap ID: 50 Automatically notify Support: No User response: Information only; no action is required. 81070217-2c03ffff Sensor Mezz Exp 3 Fault has transitioned to a less severe state from critical. Explanation: The I/O Expansion card is no longer in a fault condition.
  • Page 310 Explanation: IMM has detected that CPU 4 has recovered from a QPI Link Error. May also be shown as 8107021b0304ffff or 0x8107021b0304ffff Severity: Info Alert Category: Critical - Other Serviceable: No CIM Information: Prefix: PLAT and ID: 0523 IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 311 81070301-0301ffff • 81070301-0303ffff SNMP Trap ID: 50 Automatically notify Support: No User response: Information only; no action is required. 81070301-0301ffff Sensor CPU 1 Overtemp has deasserted the transition to non-recoverable from a less severe state. Explanation: The previously high microprocessor 1 temperature has returned to below its specified threshold. May also be shown as 810703010301ffff or 0x810703010301ffff Severity: Info Alert Category: Critical - Temperature...
  • Page 312 Explanation: The previously high I/O Expansion card temperature has returned below its specified threshold. May also be shown as 810703012c03ffff or 0x810703012c03ffff Severity: Info Alert Category: Critical - Temperature IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 313 81070301-2c04ffff • 81070301-3701ffff Serviceable: No CIM Information: Prefix: PLAT and ID: 0525 SNMP Trap ID: 0 Automatically notify Support: No User response: Information only; no action is required. 81070301-2c04ffff Sensor Mezz Exp 4 temp has deasserted the transition to non-recoverable from a less severe state.
  • Page 314 Explanation: The previously high I/O Expansion card temperature has returned below its specified threshold. May also be shown as 810706012c03ffff or 0x810706012c03ffff Severity: Info Alert Category: Critical - Temperature Serviceable: No CIM Information: Prefix: PLAT and ID: 0531 IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 315 81070601-2c04ffff • 81070617-2c01ffff SNMP Trap ID: 0 Automatically notify Support: No User response: Information only; no action is required. 81070601-2c04ffff Sensor Mezz Exp 4 temp has deasserted the transition to non-recoverable. Explanation: The previously high I/O Expansion card temperature has returned below its specified threshold. May also be shown as 810706012c04ffff or 0x810706012c04ffff Severity: Info Alert Category: Critical - Temperature...
  • Page 316 Explanation: An account with IPMI / SNMP access has been disabled. May also be shown as 810901122101ffff or 0x810901122101ffff Severity: Info Alert Category: System - Other Serviceable: No IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 317 810b010c-2581ffff • 810b050c-2581ffff CIM Information: Prefix: PLAT and ID: 0539 SNMP Trap ID: Automatically notify Support: No User response: Information only; no action is required. 810b010c-2581ffff Redundancy Lost for [RedundancySetElementName] has deasserted. Explanation: This message is for the use case when Redundacy Lost has deasserted. May also be shown as 810b010c2581ffff or 0x810b010c2581ffff Severity: Info Alert Category: Critical - Memory...
  • Page 318 User response: This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Information Center for the appropriate user response. IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 319 816f0007-0304ffff • 816f000d-0400ffff 816f0007-0304ffff [ProcessorElementName] has Recovered from IERR. Explanation: This message is for the use case when an implementation has detected a Processor Recovered - IERR Condition. May also be shown as 816f00070304ffff or 0x816f00070304ffff Severity: Info Alert Category: Critical - CPU Serviceable: No CIM Information: Prefix: PLAT and ID: 0043 SNMP Trap ID: 40...
  • Page 320 If drive was intentionally removed, no action required. v Make sure that the drive properly seated. v If drive is properly seated, replace the drive. IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 321 816f000d-0403ffff • 816f000d-0405ffff 816f000d-0403ffff The Drive [StorageVolumeElementName] has been removed from unit [PhysicalPackageElementName]. Explanation: Presence of drive 3 is no longer detected. If hard drive is absent from drive bay a filler is required. May also be shown as 816f000d0403ffff or 0x816f000d0403ffff Severity: Error Alert Category: Critical - Hard Disk drive Serviceable: Yes...
  • Page 322 SNMP Trap ID: 50 Automatically notify Support: No User response: This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 323 816f0013-1701ffff • 816f0021-2582ffff IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Information Center for the appropriate user response. 816f0013-1701ffff System [ComputerSystemElementName] has recovered from a diagnostic interrupt. Explanation: The system has recovered from a Front Panel NMI / Diagnostic Interrupt. May also be shown as 816f00131701ffff or 0x816f00131701ffff Severity: Info Alert Category: Critical - Other...
  • Page 324 Explanation: The microprocessor 3 temperature has returned to below the critical level. May also be shown as 816f01070303ffff or 0x816f01070303ffff Severity: Info Alert Category: Critical - Temperature Serviceable: No CIM Information: Prefix: PLAT and ID: 0037 IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 325 816f0107-0304ffff • 816f010c-2001ffff SNMP Trap ID: 0 Automatically notify Support: No User response: Information only; no action is required. 816f0107-0304ffff An Over-Temperature Condition has been removed on [ProcessorElementName]. Explanation: The microprocessor 4 temperature has returned to below the critical level. May also be shown as 816f01070304ffff or 0x816f01070304ffff Severity: Info Alert Category: Critical - Temperature...
  • Page 326 User response: This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Information Center for the appropriate user response. IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 327 816f010c-2005ffff • 816f010c-2007ffff 816f010c-2005ffff Uncorrectable error recovery detected for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. Explanation: This message is for the use case when an implementation has detected a Memory uncorrectable error recovery. May also be shown as 816f010c2005ffff or 0x816f010c2005ffff Severity: Info Alert Category: Critical - Memory Serviceable: No CIM Information: Prefix: PLAT and ID: 0139...
  • Page 328 User response: This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Information Center for the appropriate user response. IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 329 816f010c-200bffff • 816f010c-200dffff 816f010c-200bffff Uncorrectable error recovery detected for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. Explanation: This message is for the use case when an implementation has detected a Memory uncorrectable error recovery. May also be shown as 816f010c200bffff or 0x816f010c200bffff Severity: Info Alert Category: Critical - Memory Serviceable: No CIM Information: Prefix: PLAT and ID: 0139...
  • Page 330 User response: This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Information Center for the appropriate user response. IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 331 816f010c-2011ffff • 816f010c-2013ffff 816f010c-2011ffff Uncorrectable error recovery detected for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. Explanation: This message is for the use case when an implementation has detected a Memory uncorrectable error recovery. May also be shown as 816f010c2011ffff or 0x816f010c2011ffff Severity: Info Alert Category: Critical - Memory Serviceable: No CIM Information: Prefix: PLAT and ID: 0139...
  • Page 332 User response: This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Information Center for the appropriate user response. IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 333 816f010c-2017ffff • 816f010c-2019ffff 816f010c-2017ffff Uncorrectable error recovery detected for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. Explanation: This message is for the use case when an implementation has detected a Memory uncorrectable error recovery. May also be shown as 816f010c2017ffff or 0x816f010c2017ffff Severity: Info Alert Category: Critical - Memory Serviceable: No CIM Information: Prefix: PLAT and ID: 0139...
  • Page 334 User response: This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Information Center for the appropriate user response. IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 335 816f010c-201dffff • 816f010c-201fffff 816f010c-201dffff Uncorrectable error recovery detected for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. Explanation: This message is for the use case when an implementation has detected a Memory uncorrectable error recovery. May also be shown as 816f010c201dffff or 0x816f010c201dffff Severity: Info Alert Category: Critical - Memory Serviceable: No CIM Information: Prefix: PLAT and ID: 0139...
  • Page 336 User response: This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Information Center for the appropriate user response. IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 337 816f010c-2023ffff • 816f010c-2025ffff 816f010c-2023ffff Uncorrectable error recovery detected for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. Explanation: This message is for the use case when an implementation has detected a Memory uncorrectable error recovery. May also be shown as 816f010c2023ffff or 0x816f010c2023ffff Severity: Info Alert Category: Critical - Memory Serviceable: No CIM Information: Prefix: PLAT and ID: 0139...
  • Page 338 User response: This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Information Center for the appropriate user response. IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 339 816f010c-2029ffff • 816f010c-202bffff 816f010c-2029ffff Uncorrectable error recovery detected for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. Explanation: This message is for the use case when an implementation has detected a Memory uncorrectable error recovery. May also be shown as 816f010c2029ffff or 0x816f010c2029ffff Severity: Info Alert Category: Critical - Memory Serviceable: No CIM Information: Prefix: PLAT and ID: 0139...
  • Page 340 User response: This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Information Center for the appropriate user response. IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 341 816f010c-202fffff • 816f010c-2581ffff 816f010c-202fffff Uncorrectable error recovery detected for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. Explanation: This message is for the use case when an implementation has detected a Memory uncorrectable error recovery. May also be shown as 816f010c202fffff or 0x816f010c202fffff Severity: Info Alert Category: Critical - Memory Serviceable: No CIM Information: Prefix: PLAT and ID: 0139...
  • Page 342 May also be shown as 816f010d0403ffff or 0x816f010d0403ffff Severity: Info Alert Category: Critical - Hard Disk drive Serviceable: No CIM Information: Prefix: PLAT and ID: 0167 IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 343 816f010d-0404ffff • 816f010d-0407ffff SNMP Trap ID: 5 Automatically notify Support: No User response: Information only; no action is required. 816f010d-0404ffff The Drive [StorageVolumeElementName] has been enabled. Explanation: The previously disabled drive 4 has been enabled. May also be shown as 816f010d0404ffff or 0x816f010d0404ffff Severity: Info Alert Category: Critical - Hard Disk drive Serviceable: No...
  • Page 344 FRB1/BIST condition. May also be shown as 816f02070302ffff or 0x816f02070302ffff Severity: Info Alert Category: Critical - CPU Serviceable: No CIM Information: Prefix: PLAT and ID: 0045 IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 345 816f0207-0303ffff • 816f0207-2584ffff SNMP Trap ID: 40 Automatically notify Support: No User response: This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Information Center for the appropriate user response.
  • Page 346 Alert Category: System - Predicted Failure Serviceable: No CIM Information: Prefix: PLAT and ID: 0169 SNMP Trap ID: 27 Automatically notify Support: No User response: Information only; no action is required. IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 347 816f020d-0403ffff • 816f020d-0406ffff 816f020d-0403ffff Failure no longer Predicted on drive [StorageVolumeElementName] for array [ComputerSystemElementName]. Explanation: The predicted failure for Drive 3 no longer exists. May also be shown as 816f020d0403ffff or 0x816f020d0403ffff Severity: Info Alert Category: System - Predicted Failure Serviceable: No CIM Information: Prefix: PLAT and ID: 0169 SNMP Trap ID: 27...
  • Page 348 Alert Category: System - Other Serviceable: No CIM Information: Prefix: PLAT and ID: 0395 SNMP Trap ID: Automatically notify Support: No User response: Information only; no action is required. IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 349 816f030c-2001ffff • 816f030c-2004ffff 816f030c-2001ffff Scrub Failure for [PhysicalMemoryElementName] on Subsystem [MemoryElementName] has recovered. Explanation: A Memory Scrub failure detected during boot has recovered. May also be shown as 816f030c2001ffff or 0x816f030c2001ffff Severity: Info Alert Category: Critical - Memory Serviceable: No CIM Information: Prefix: PLAT and ID: 0137 SNMP Trap ID: 41 Automatically notify Support: No...
  • Page 350 Alert Category: Critical - Memory Serviceable: No CIM Information: Prefix: PLAT and ID: 0137 SNMP Trap ID: 41 Automatically notify Support: No User response: Information only; no action is required. IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 351 816f030c-2008ffff • 816f030c-200bffff 816f030c-2008ffff Scrub Failure for [PhysicalMemoryElementName] on Subsystem [MemoryElementName] has recovered. Explanation: A Memory Scrub failure detected during boot has recovered. May also be shown as 816f030c2008ffff or 0x816f030c2008ffff Severity: Info Alert Category: Critical - Memory Serviceable: No CIM Information: Prefix: PLAT and ID: 0137 SNMP Trap ID: 41 Automatically notify Support: No...
  • Page 352 Alert Category: Critical - Memory Serviceable: No CIM Information: Prefix: PLAT and ID: 0137 SNMP Trap ID: 41 Automatically notify Support: No User response: Information only; no action is required. IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 353 816f030c-200fffff • 816f030c-2012ffff 816f030c-200fffff Scrub Failure for [PhysicalMemoryElementName] on Subsystem [MemoryElementName] has recovered. Explanation: A Memory Scrub failure detected during boot has recovered. May also be shown as 816f030c200fffff or 0x816f030c200fffff Severity: Info Alert Category: Critical - Memory Serviceable: No CIM Information: Prefix: PLAT and ID: 0137 SNMP Trap ID: 41 Automatically notify Support: No...
  • Page 354 Alert Category: Critical - Memory Serviceable: No CIM Information: Prefix: PLAT and ID: 0137 SNMP Trap ID: 41 Automatically notify Support: No User response: Information only; no action is required. IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 355 816f030c-2016ffff • 816f030c-2019ffff 816f030c-2016ffff Scrub Failure for [PhysicalMemoryElementName] on Subsystem [MemoryElementName] has recovered. Explanation: A Memory Scrub failure detected during boot has recovered. May also be shown as 816f030c2016ffff or 0x816f030c2016ffff Severity: Info Alert Category: Critical - Memory Serviceable: No CIM Information: Prefix: PLAT and ID: 0137 SNMP Trap ID: 41 Automatically notify Support: No...
  • Page 356 Alert Category: Critical - Memory Serviceable: No CIM Information: Prefix: PLAT and ID: 0137 SNMP Trap ID: 41 Automatically notify Support: No User response: Information only; no action is required. IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 357 816f030c-201dffff • 816f030c-2020ffff 816f030c-201dffff Scrub Failure for [PhysicalMemoryElementName] on Subsystem [MemoryElementName] has recovered. Explanation: A Memory Scrub failure detected during boot has recovered. May also be shown as 816f030c201dffff or 0x816f030c201dffff Severity: Info Alert Category: Critical - Memory Serviceable: No CIM Information: Prefix: PLAT and ID: 0137 SNMP Trap ID: 41 Automatically notify Support: No...
  • Page 358 Alert Category: Critical - Memory Serviceable: No CIM Information: Prefix: PLAT and ID: 0137 SNMP Trap ID: 41 Automatically notify Support: No User response: Information only; no action is required. IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 359 816f030c-2024ffff • 816f030c-2027ffff 816f030c-2024ffff Scrub Failure for [PhysicalMemoryElementName] on Subsystem [MemoryElementName] has recovered. Explanation: A Memory Scrub failure detected during boot has recovered. May also be shown as 816f030c2024ffff or 0x816f030c2024ffff Severity: Info Alert Category: Critical - Memory Serviceable: No CIM Information: Prefix: PLAT and ID: 0137 SNMP Trap ID: 41 Automatically notify Support: No...
  • Page 360 Alert Category: Critical - Memory Serviceable: No CIM Information: Prefix: PLAT and ID: 0137 SNMP Trap ID: 41 Automatically notify Support: No User response: Information only; no action is required. IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 361 816f030c-202bffff • 816f030c-202effff 816f030c-202bffff Scrub Failure for [PhysicalMemoryElementName] on Subsystem [MemoryElementName] has recovered. Explanation: A Memory Scrub failure detected during boot has recovered. May also be shown as 816f030c202bffff or 0x816f030c202bffff Severity: Info Alert Category: Critical - Memory Serviceable: No CIM Information: Prefix: PLAT and ID: 0137 SNMP Trap ID: 41 Automatically notify Support: No...
  • Page 362 Alert Category: Critical - Memory Serviceable: No CIM Information: Prefix: PLAT and ID: 0137 SNMP Trap ID: 41 Automatically notify Support: No User response: Information only; no action is required. IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 363 816f0313-1701ffff • 816f040c-2003ffff 816f0313-1701ffff System [ComputerSystemElementName] has recovered from an NMI. Explanation: This message is for the use case when an implementation has detected a Software NMI has been Recovered from. May also be shown as 816f03131701ffff or 0x816f03131701ffff Severity: Info Alert Category: Critical - Other Serviceable: No CIM Information: Prefix: PLAT and ID: 0230...
  • Page 364 May also be shown as 816f040c2006ffff or 0x816f040c2006ffff Severity: Info Alert Category: System - Other Serviceable: No CIM Information: Prefix: PLAT and ID: 0130 SNMP Trap ID: IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 365 816f040c-2007ffff • 816f040c-2009ffff Automatically notify Support: No User response: This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Information Center for the appropriate user response.
  • Page 366 Explanation: This message is for the use case when an implementation has detected that Memory has been Enabled. May also be shown as 816f040c200dffff or 0x816f040c200dffff Severity: Info IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 367 816f040c-200effff • 816f040c-2010ffff Alert Category: System - Other Serviceable: No CIM Information: Prefix: PLAT and ID: 0130 SNMP Trap ID: Automatically notify Support: No User response: This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text.
  • Page 368 User response: This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Information Center for the appropriate user response. IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 369 816f040c-2014ffff • 816f040c-2017ffff 816f040c-2014ffff [PhysicalMemoryElementName] Enabled on Subsystem [MemoryElementName]. Explanation: This message is for the use case when an implementation has detected that Memory has been Enabled. May also be shown as 816f040c2014ffff or 0x816f040c2014ffff Severity: Info Alert Category: System - Other Serviceable: No CIM Information: Prefix: PLAT and ID: 0130 SNMP Trap ID:...
  • Page 370 May also be shown as 816f040c201affff or 0x816f040c201affff Severity: Info Alert Category: System - Other Serviceable: No CIM Information: Prefix: PLAT and ID: 0130 SNMP Trap ID: IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 371 816f040c-201bffff • 816f040c-201dffff Automatically notify Support: No User response: This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Information Center for the appropriate user response.
  • Page 372 Explanation: This message is for the use case when an implementation has detected that Memory has been Enabled. May also be shown as 816f040c2021ffff or 0x816f040c2021ffff Severity: Info IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 373 816f040c-2022ffff • 816f040c-2024ffff Alert Category: System - Other Serviceable: No CIM Information: Prefix: PLAT and ID: 0130 SNMP Trap ID: Automatically notify Support: No User response: This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text.
  • Page 374 User response: This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Information Center for the appropriate user response. IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 375 816f040c-2028ffff • 816f040c-202bffff 816f040c-2028ffff [PhysicalMemoryElementName] Enabled on Subsystem [MemoryElementName]. Explanation: This message is for the use case when an implementation has detected that Memory has been Enabled. May also be shown as 816f040c2028ffff or 0x816f040c2028ffff Severity: Info Alert Category: System - Other Serviceable: No CIM Information: Prefix: PLAT and ID: 0130 SNMP Trap ID:...
  • Page 376 May also be shown as 816f040c202effff or 0x816f040c202effff Severity: Info Alert Category: System - Other Serviceable: No CIM Information: Prefix: PLAT and ID: 0130 SNMP Trap ID: IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 377 816f040c-202fffff • 816f040c-2581ffff Automatically notify Support: No User response: This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Information Center for the appropriate user response.
  • Page 378 User response: This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Information Center for the appropriate user response. IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 379 816f0507-0303ffff • 816f0507-2584ffff 816f0507-0303ffff [ProcessorElementName] has Recovered from a Configuration Mismatch. Explanation: This message is for the use case when an implementation has Recovered from a Processor Configuration Mismatch. May also be shown as 816f05070303ffff or 0x816f05070303ffff Severity: Info Alert Category: Critical - CPU Serviceable: No CIM Information: Prefix: PLAT and ID: 0063 SNMP Trap ID: 40...
  • Page 380 User response: This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Information Center for the appropriate user response. IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 381 816f050c-2004ffff • 816f050c-2006ffff 816f050c-2004ffff Memory Logging Limit Removed for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. Explanation: This message is for the use case when an implementation has detected that the Memory Logging Limit has been Removed. May also be shown as 816f050c2004ffff or 0x816f050c2004ffff Severity: Info Alert Category: Warning - Memory Serviceable: No...
  • Page 382 User response: This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Information Center for the appropriate user response. IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 383 816f050c-200affff • 816f050c-200cffff 816f050c-200affff Memory Logging Limit Removed for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. Explanation: This message is for the use case when an implementation has detected that the Memory Logging Limit has been Removed. May also be shown as 816f050c200affff or 0x816f050c200affff Severity: Info Alert Category: Warning - Memory Serviceable: No...
  • Page 384 User response: This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Information Center for the appropriate user response. IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 385 816f050c-2010ffff • 816f050c-2012ffff 816f050c-2010ffff Memory Logging Limit Removed for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. Explanation: This message is for the use case when an implementation has detected that the Memory Logging Limit has been Removed. May also be shown as 816f050c2010ffff or 0x816f050c2010ffff Severity: Info Alert Category: Warning - Memory Serviceable: No...
  • Page 386 User response: This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Information Center for the appropriate user response. IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 387 816f050c-2016ffff • 816f050c-2018ffff 816f050c-2016ffff Memory Logging Limit Removed for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. Explanation: This message is for the use case when an implementation has detected that the Memory Logging Limit has been Removed. May also be shown as 816f050c2016ffff or 0x816f050c2016ffff Severity: Info Alert Category: Warning - Memory Serviceable: No...
  • Page 388 User response: This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Information Center for the appropriate user response. IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 389 816f050c-201cffff • 816f050c-201effff 816f050c-201cffff Memory Logging Limit Removed for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. Explanation: This message is for the use case when an implementation has detected that the Memory Logging Limit has been Removed. May also be shown as 816f050c201cffff or 0x816f050c201cffff Severity: Info Alert Category: Warning - Memory Serviceable: No...
  • Page 390 User response: This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Information Center for the appropriate user response. IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 391 816f050c-2022ffff • 816f050c-2024ffff 816f050c-2022ffff Memory Logging Limit Removed for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. Explanation: This message is for the use case when an implementation has detected that the Memory Logging Limit has been Removed. May also be shown as 816f050c2022ffff or 0x816f050c2022ffff Severity: Info Alert Category: Warning - Memory Serviceable: No...
  • Page 392 User response: This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Information Center for the appropriate user response. IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 393 816f050c-2028ffff • 816f050c-202affff 816f050c-2028ffff Memory Logging Limit Removed for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. Explanation: This message is for the use case when an implementation has detected that the Memory Logging Limit has been Removed. May also be shown as 816f050c2028ffff or 0x816f050c2028ffff Severity: Info Alert Category: Warning - Memory Serviceable: No...
  • Page 394 User response: This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Information Center for the appropriate user response. IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 395 816f050c-202effff • 816f050c-2030ffff 816f050c-202effff Memory Logging Limit Removed for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. Explanation: This message is for the use case when an implementation has detected that the Memory Logging Limit has been Removed. May also be shown as 816f050c202effff or 0x816f050c202effff Severity: Info Alert Category: Warning - Memory Serviceable: No...
  • Page 396 Explanation: The RAID array is no longer in a critical condition. May also be shown as 816f050d0402ffff or 0x816f050d0402ffff Severity: Info Alert Category: Critical - Hard Disk drive IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 397 816f050d-0403ffff • 816f050d-0405ffff Serviceable: No CIM Information: Prefix: PLAT and ID: 0175 SNMP Trap ID: 5 Automatically notify Support: No User response: Information only; no action is required. 816f050d-0403ffff Critical Array [ComputerSystemElementName] has deasserted. Explanation: The RAID array is no longer in a critical condition. May also be shown as 816f050d0403ffff or 0x816f050d0403ffff Severity: Info Alert Category: Critical - Hard Disk drive...
  • Page 398 Explanation: This message is for the use case when an SM BIOS Uncorrectable CPU complex error has deasserted. May also be shown as 816f06070301ffff or 0x816f06070301ffff Severity: Info Alert Category: Critical - CPU Serviceable: No IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 399 816f0607-0302ffff • 816f0607-0304ffff CIM Information: Prefix: PLAT and ID: 0817 SNMP Trap ID: 40 Automatically notify Support: No User response: This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Information Center for the appropriate user response.
  • Page 400 816f060d-0402ffff Array in system [ComputerSystemElementName] has been restored. Explanation: The failed RAID array has been restored. May also be shown as 816f060d0402ffff or 0x816f060d0402ffff Severity: Info IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 401 816f060d-0403ffff • 816f060d-0405ffff Alert Category: Critical - Hard Disk drive Serviceable: No CIM Information: Prefix: PLAT and ID: 0177 SNMP Trap ID: 5 Automatically notify Support: No User response: Information only; no action is required. 816f060d-0403ffff Array in system [ComputerSystemElementName] has been restored. Explanation: The failed RAID array has been restored.
  • Page 402 Explanation: This message is for the use case when an implementation has detected a Memory DIMM configuration error has deasserted. May also be shown as 816f070c2002ffff or 0x816f070c2002ffff Severity: Info IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 403 816f070c-2003ffff • 816f070c-2005ffff Alert Category: Critical - Memory Serviceable: No CIM Information: Prefix: PLAT and ID: 0127 SNMP Trap ID: 41 Automatically notify Support: No User response: This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text.
  • Page 404 Explanation: This message is for the use case when an implementation has detected a Memory DIMM configuration error has deasserted. May also be shown as 816f070c2008ffff or 0x816f070c2008ffff Severity: Info IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 405 816f070c-2009ffff • 816f070c-200bffff Alert Category: Critical - Memory Serviceable: No CIM Information: Prefix: PLAT and ID: 0127 SNMP Trap ID: 41 Automatically notify Support: No User response: This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text.
  • Page 406 Explanation: This message is for the use case when an implementation has detected a Memory DIMM configuration error has deasserted. May also be shown as 816f070c200effff or 0x816f070c200effff Severity: Info IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 407 816f070c-200fffff • 816f070c-2011ffff Alert Category: Critical - Memory Serviceable: No CIM Information: Prefix: PLAT and ID: 0127 SNMP Trap ID: 41 Automatically notify Support: No User response: This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text.
  • Page 408 Explanation: This message is for the use case when an implementation has detected a Memory DIMM configuration error has deasserted. May also be shown as 816f070c2014ffff or 0x816f070c2014ffff Severity: Info IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 409 816f070c-2015ffff • 816f070c-2017ffff Alert Category: Critical - Memory Serviceable: No CIM Information: Prefix: PLAT and ID: 0127 SNMP Trap ID: 41 Automatically notify Support: No User response: This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text.
  • Page 410 Explanation: This message is for the use case when an implementation has detected a Memory DIMM configuration error has deasserted. May also be shown as 816f070c201affff or 0x816f070c201affff Severity: Info IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 411 816f070c-201bffff • 816f070c-201dffff Alert Category: Critical - Memory Serviceable: No CIM Information: Prefix: PLAT and ID: 0127 SNMP Trap ID: 41 Automatically notify Support: No User response: This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text.
  • Page 412 Explanation: This message is for the use case when an implementation has detected a Memory DIMM configuration error has deasserted. May also be shown as 816f070c2020ffff or 0x816f070c2020ffff Severity: Info IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 413 816f070c-2021ffff • 816f070c-2023ffff Alert Category: Critical - Memory Serviceable: No CIM Information: Prefix: PLAT and ID: 0127 SNMP Trap ID: 41 Automatically notify Support: No User response: This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text.
  • Page 414 Explanation: This message is for the use case when an implementation has detected a Memory DIMM configuration error has deasserted. May also be shown as 816f070c2026ffff or 0x816f070c2026ffff Severity: Info IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 415 816f070c-2027ffff • 816f070c-2029ffff Alert Category: Critical - Memory Serviceable: No CIM Information: Prefix: PLAT and ID: 0127 SNMP Trap ID: 41 Automatically notify Support: No User response: This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text.
  • Page 416 Explanation: This message is for the use case when an implementation has detected a Memory DIMM configuration error has deasserted. May also be shown as 816f070c202cffff or 0x816f070c202cffff Severity: Info IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 417 816f070c-202dffff • 816f070c-202fffff Alert Category: Critical - Memory Serviceable: No CIM Information: Prefix: PLAT and ID: 0127 SNMP Trap ID: 41 Automatically notify Support: No User response: This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text.
  • Page 418 Rebuild completed for Array in system [ComputerSystemElementName]. Explanation: The rebuild of the RAID array has completed. May also be shown as 816f070d0400ffff or 0x816f070d0400ffff Severity: Info Alert Category: System - Other IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 419 816f070d-0401ffff • 816f070d-0403ffff Serviceable: No CIM Information: Prefix: PLAT and ID: 0179 SNMP Trap ID: Automatically notify Support: No User response: Information only; no action is required. 816f070d-0401ffff Rebuild completed for Array in system [ComputerSystemElementName]. Explanation: The rebuild of the RAID array has completed. May also be shown as 816f070d0401ffff or 0x816f070d0401ffff Severity: Info Alert Category: System - Other...
  • Page 420 Explanation: The rebuild of the RAID array has completed. May also be shown as 816f070d0407ffff or 0x816f070d0407ffff Severity: Info Alert Category: System - Other Serviceable: No CIM Information: Prefix: PLAT and ID: 0179 IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 421 816f0807-0301ffff • 816f0807-0303ffff SNMP Trap ID: Automatically notify Support: No User response: Information only; no action is required. 816f0807-0301ffff [ProcessorElementName] has been Enabled. Explanation: This message is for the use case when an implementation has detected a Processor has been Enabled. May also be shown as 816f08070301ffff or 0x816f08070301ffff Severity: Info Alert Category: System - Other...
  • Page 422 User response: This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Information Center for the appropriate user response. IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 423 816f0813-2584ffff • 816f090c-2003ffff 816f0813-2584ffff Bus [SensorElementName] has recovered from an Uncorrectable Bus Error. Explanation: This message is for the use case when an implementation has detected a that a system has recovered from a Bus Uncorrectable Error. CPUs. May also be shown as 816f08132584ffff or 0x816f08132584ffff Severity: Info Alert Category: Critical - Other Serviceable: No...
  • Page 424 Alert Category: System - Other Serviceable: No CIM Information: Prefix: PLAT and ID: 0143 SNMP Trap ID: Automatically notify Support: No User response: Information only; no action is required. IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 425 816f090c-2007ffff • 816f090c-200affff 816f090c-2007ffff [PhysicalMemoryElementName] on Subsystem [MemoryElementName] is no longer Throttled. Explanation: Memory DIMM throttling has been turned off. May also be shown as 816f090c2007ffff or 0x816f090c2007ffff Severity: Info Alert Category: System - Other Serviceable: No CIM Information: Prefix: PLAT and ID: 0143 SNMP Trap ID: Automatically notify Support: No User response: Information only;...
  • Page 426 [PhysicalMemoryElementName] on Subsystem [MemoryElementName] is no longer Throttled. Explanation: Memory DIMM throttling has been turned off. May also be shown as 816f090c200effff or 0x816f090c200effff Severity: Info IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 427 816f090c-200fffff • 816f090c-2011ffff Alert Category: System - Other Serviceable: No CIM Information: Prefix: PLAT and ID: 0143 SNMP Trap ID: Automatically notify Support: No User response: Information only; no action is required. 816f090c-200fffff [PhysicalMemoryElementName] on Subsystem [MemoryElementName] is no longer Throttled. Explanation: Memory DIMM throttling has been turned off.
  • Page 428 Explanation: Memory DIMM throttling has been turned off. May also be shown as 816f090c2015ffff or 0x816f090c2015ffff Severity: Info Alert Category: System - Other Serviceable: No CIM Information: Prefix: PLAT and ID: 0143 IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 429 816f090c-2016ffff • 816f090c-2019ffff SNMP Trap ID: Automatically notify Support: No User response: Information only; no action is required. 816f090c-2016ffff [PhysicalMemoryElementName] on Subsystem [MemoryElementName] is no longer Throttled. Explanation: Memory DIMM throttling has been turned off. May also be shown as 816f090c2016ffff or 0x816f090c2016ffff Severity: Info Alert Category: System - Other Serviceable: No...
  • Page 430 Alert Category: System - Other Serviceable: No CIM Information: Prefix: PLAT and ID: 0143 SNMP Trap ID: Automatically notify Support: No User response: Information only; no action is required. IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 431 816f090c-201dffff • 816f090c-2020ffff 816f090c-201dffff [PhysicalMemoryElementName] on Subsystem [MemoryElementName] is no longer Throttled. Explanation: Memory DIMM throttling has been turned off. May also be shown as 816f090c201dffff or 0x816f090c201dffff Severity: Info Alert Category: System - Other Serviceable: No CIM Information: Prefix: PLAT and ID: 0143 SNMP Trap ID: Automatically notify Support: No User response: Information only;...
  • Page 432 [PhysicalMemoryElementName] on Subsystem [MemoryElementName] is no longer Throttled. Explanation: Memory DIMM throttling has been turned off. May also be shown as 816f090c2024ffff or 0x816f090c2024ffff Severity: Info IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 433 816f090c-2025ffff • 816f090c-2027ffff Alert Category: System - Other Serviceable: No CIM Information: Prefix: PLAT and ID: 0143 SNMP Trap ID: Automatically notify Support: No User response: Information only; no action is required. 816f090c-2025ffff [PhysicalMemoryElementName] on Subsystem [MemoryElementName] is no longer Throttled. Explanation: Memory DIMM throttling has been turned off.
  • Page 434 Explanation: Memory DIMM throttling has been turned off. May also be shown as 816f090c202bffff or 0x816f090c202bffff Severity: Info Alert Category: System - Other Serviceable: No CIM Information: Prefix: PLAT and ID: 0143 IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 435 816f090c-202cffff • 816f090c-202fffff SNMP Trap ID: Automatically notify Support: No User response: Information only; no action is required. 816f090c-202cffff [PhysicalMemoryElementName] on Subsystem [MemoryElementName] is no longer Throttled. Explanation: Memory DIMM throttling has been turned off. May also be shown as 816f090c202cffff or 0x816f090c202cffff Severity: Info Alert Category: System - Other Serviceable: No...
  • Page 436 Alert Category: Warning - CPU Serviceable: No CIM Information: Prefix: PLAT and ID: 0039 SNMP Trap ID: 42 Automatically notify Support: No User response: Information only; no action is required. IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 437 816f0a07-0302ffff • 816f0a07-2584ffff 816f0a07-0302ffff The Processor [ProcessorElementName] is no longer operating in a Degraded State. Explanation: The microprocessor 2 is no longer being throttled. (or ... has been turned off.) May also be shown as 816f0a070302ffff or 0x816f0a070302ffff Severity: Info Alert Category: Warning - CPU Serviceable: No CIM Information: Prefix: PLAT and ID: 0039...
  • Page 438 Alert Category: Critical - Temperature Serviceable: No CIM Information: Prefix: PLAT and ID: 0147 SNMP Trap ID: 0 Automatically notify Support: No User response: Information only; no action is required. IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 439 816f0a0c-2004ffff • 816f0a0c-2007ffff 816f0a0c-2004ffff An Over-Temperature Condition has been removed on the [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. Explanation: Memory DIMM is no longer in an over-temperature condition. May also be shown as 816f0a0c2004ffff or 0x816f0a0c2004ffff Severity: Info Alert Category: Critical - Temperature Serviceable: No CIM Information: Prefix: PLAT and ID: 0147 SNMP Trap ID: 0...
  • Page 440 Alert Category: Critical - Temperature Serviceable: No CIM Information: Prefix: PLAT and ID: 0147 SNMP Trap ID: 0 Automatically notify Support: No User response: Information only; no action is required. IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 441 816f0a0c-200bffff • 816f0a0c-200effff 816f0a0c-200bffff An Over-Temperature Condition has been removed on the [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. Explanation: Memory DIMM is no longer in an over-temperature condition. May also be shown as 816f0a0c200bffff or 0x816f0a0c200bffff Severity: Info Alert Category: Critical - Temperature Serviceable: No CIM Information: Prefix: PLAT and ID: 0147 SNMP Trap ID: 0...
  • Page 442 Alert Category: Critical - Temperature Serviceable: No CIM Information: Prefix: PLAT and ID: 0147 SNMP Trap ID: 0 Automatically notify Support: No User response: Information only; no action is required. IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 443 816f0a0c-2012ffff • 816f0a0c-2015ffff 816f0a0c-2012ffff An Over-Temperature Condition has been removed on the [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. Explanation: Memory DIMM is no longer in an over-temperature condition. May also be shown as 816f0a0c2012ffff or 0x816f0a0c2012ffff Severity: Info Alert Category: Critical - Temperature Serviceable: No CIM Information: Prefix: PLAT and ID: 0147 SNMP Trap ID: 0...
  • Page 444 Alert Category: Critical - Temperature Serviceable: No CIM Information: Prefix: PLAT and ID: 0147 SNMP Trap ID: 0 Automatically notify Support: No User response: Information only; no action is required. IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 445 816f0a0c-2019ffff • 816f0a0c-201cffff 816f0a0c-2019ffff An Over-Temperature Condition has been removed on the [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. Explanation: Memory DIMM is no longer in an over-temperature condition. May also be shown as 816f0a0c2019ffff or 0x816f0a0c2019ffff Severity: Info Alert Category: Critical - Temperature Serviceable: No CIM Information: Prefix: PLAT and ID: 0147 SNMP Trap ID: 0...
  • Page 446 Alert Category: Critical - Temperature Serviceable: No CIM Information: Prefix: PLAT and ID: 0147 SNMP Trap ID: 0 Automatically notify Support: No User response: Information only; no action is required. IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 447 816f0a0c-2020ffff • 816f0a0c-2023ffff 816f0a0c-2020ffff An Over-Temperature Condition has been removed on the [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. Explanation: Memory DIMM is no longer in an over-temperature condition. May also be shown as 816f0a0c2020ffff or 0x816f0a0c2020ffff Severity: Info Alert Category: Critical - Temperature Serviceable: No CIM Information: Prefix: PLAT and ID: 0147 SNMP Trap ID: 0...
  • Page 448 Alert Category: Critical - Temperature Serviceable: No CIM Information: Prefix: PLAT and ID: 0147 SNMP Trap ID: 0 Automatically notify Support: No User response: Information only; no action is required. IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 449 816f0a0c-2027ffff • 816f0a0c-202affff 816f0a0c-2027ffff An Over-Temperature Condition has been removed on the [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. Explanation: Memory DIMM is no longer in an over-temperature condition. May also be shown as 816f0a0c2027ffff or 0x816f0a0c2027ffff Severity: Info Alert Category: Critical - Temperature Serviceable: No CIM Information: Prefix: PLAT and ID: 0147 SNMP Trap ID: 0...
  • Page 450 Alert Category: Critical - Temperature Serviceable: No CIM Information: Prefix: PLAT and ID: 0147 SNMP Trap ID: 0 Automatically notify Support: No User response: Information only; no action is required. IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 451 816f0a0c-202effff • 816f0a0c-2581ffff 816f0a0c-202effff An Over-Temperature Condition has been removed on the [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. Explanation: Memory DIMM is no longer in an over-temperature condition. May also be shown as 816f0a0c202effff or 0x816f0a0c202effff Severity: Info Alert Category: Critical - Temperature Serviceable: No CIM Information: Prefix: PLAT and ID: 0147 SNMP Trap ID: 0...
  • Page 452 May also be shown as 816f0b130701ffff or 0x816f0b130701ffff Severity: Info Alert Category: Warning - Other Serviceable: No CIM Information: Prefix: PLAT and ID: 0247 SNMP Trap ID: 60 Automatically notify Support: No IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 453: Uefi Diagnostic Codes

    Perform the steps listed in this section in the order shown until the problem is solved. After you perform all of the actions that are described in this field, if you cannot solve the problem, contact IBM Support. I.11002 [I.11002] A processor mismatch has been detected between one or more processors in the system.
  • Page 454 Verify that the Processor’s are installed in the correct sockets according to the service information for this product. If not, correct that problem. Check IBM support site for an applicable service bulletin or firmware update that applies to this Processor error. (Trained Service technician only) Replace mismatching processor. Inspect Processor socket and replace the system board first if socket is damaged.
  • Page 455 Correct any mismatch issues found. Check IBM support site for an applicable service bulletin or firmware update that applies to this Processor error. (Trained Service technician only) Replace Processor. Inspect Processor socket and replace the system board first if socket is damaged.
  • Page 456 Verify that matching Processors are installed in the correct Processor sockets according to the service information for this product. Check IBM support site for an applicable service bulletin or firmware update that applies to this Processor error. (Trained Service technician only) Replace the system board.
  • Page 457 Move adapter to a different system slot, if available. Check IBM support site for any applicable service bulletin or UEFI or adapter firmware update that applies to this error. NOTE: It may be necessary to configure slot to Gen1 or to use special utility software so that adapter firmware can be upgraded.
  • Page 458 [I.580A5] Mirror Fail-over complete. DIMM number % has failed over to to the mirrored copy. Explanation: DIMM Mirror Fail-over Detected Severity: Info User response: Complete the following step: Check the system-event log for uncorrected DIMM failures and replace those DIMMs. IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 459 Explanation: Uncorrectable processor error detected Severity: Error User response: Complete the following steps: Check IBM support site for an applicable service bulletin or firmware update that applies to this error. Reboot system. If problem persists escalate to the next level of supprt. S.2011001 [S.2011001] An Uncorrected PCIe Error has Occurred at Bus % Device % Function %.
  • Page 460 Explanation: Internal UEFI Firmware Fault Detected, System halted Severity: Error User response: Complete the following steps: Check IBM support site for an applicable service bulletin or firmware update that applies to this error. Reflash UEFI image. (Trained service technician only) Replace the system board.
  • Page 461 CMOS battery for 30 seconds to clear CMOS contents. Verify that the system boots. Then, re-install options one at a time to locate the problem. Check IBM support site for an applicable service bulletin or firmware update that applies to this error. Reflash UEFI firmware.
  • Page 462 If problem re-occurs on the same DIMM connector, replace the other DIMMs on the same memory channel. Check IBM support site for an applicable service bulletin or firmware update that applies to this memory error. (Trained Service technician only) If problem re-occurs on the same DIMM connector, inspect connector for damage.
  • Page 463 DIMM. Check IBM support site for an applicable service bulletin or firmware update that applies to this memory error. (Trained service technician only) If problem stays with the original DIMM connector, re-inspect DIMM connector for foreign material and remove, if found.
  • Page 464 Severity: Warning User response: Complete the following steps: If the Processor or firmware was just updated, check IBM support site for an applicable service bulletin or firmware update that applies to this Processor error. (Trained service technician only) If there are multiple Processor’s, swap Processor’s to move affected Processor to another Processor socket and retry.
  • Page 465 W.305800A • W.305800E Go to System Settings > Settings > Driver Health Status List and find a driver/controller reporting Configuration Required status. Search for the driver menu from System Settings and change settings appropriately. Save settings and restart system. W.305800A [W.305800A] DRIVER HEALTH PROTOCOL: Reports 'Failed' Status Controller.
  • Page 466 Reset the IMM from the CMM. Use CMM to remove AUX power from the node. This will reboot the entire node. Check IBM support site for an applicable service bulletin or firmware update that applies to this error. Reflash UEFI Firmware.
  • Page 467 DIMM population that could be related to this problem.) Check IBM support site for an applicable firmware update that applies to this memory error. The release notes will list the known problems the update addresses.
  • Page 468 If PFA follows a moved DIMM to any DIMM connector on the different memory channel, replace the moved DIMM. Check IBM support site for an applicable Service Bulletins (Service bulletins) that applies to this memory error. (Link to IBM support service bulletins) (Trained service technician only) If problem continues to re-occur on the same DIMM connector, inspect DIMM connector for foreign material and remove, if found.
  • Page 469: Dsa Messages

    DSA log within the Firmware/VPD section for this component. The latest level firmware for this component can be found at http://www.ibm.com/support/fixcentral/. 4. If the compute node has stopped responding, turn off and restart the compute node; then, run the test again. See “Turning off the compute node”...
  • Page 470 See Chapter 5, “Parts listing, Types 7917 and 2584,” on page 51 to determine which components are Tier 1 customer replaceable units (CRUs) and which components are Tier 2 customer replaceable units (CRUs). IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 471: Troubleshooting By Symptom

    Use this information to solve connectivity problems. The IBM Flex System Manager management node cannot communicate with a compute node Use the information in this section to troubleshoot the IBM Flex System Managermanagement node when the management node cannot communicate with a compute node.
  • Page 472 Use the information in this section to troubleshoot the compute node when you cannot connect during initial setup. One compute node is unable to connect during the initial setup: IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 473 5. Remove the compute node from the chassis and check the connectors at the back of the node for bent pins. If the pins are bent, contact IBM Support. See “Removing a compute node from a chassis” on page 489.
  • Page 474 The event is logged in the event log. See the event log for the IBM Flex System Manager management node (if installed) or see the event log of the CMM to determine what actions might be required to resolve this issue. See “IMM event log”...
  • Page 475 The event is logged in the event log. See the event log for the IBM Flex System Manager management node (if installed) or see the event log of the CMM to determine what actions might be required to resolve this issue. See “IMM event log”...
  • Page 476 5. Remove the compute node from the chassis and check the connectors on the back of the node for bent pins. If the pins are bent, contact IBM Support. 6. Install the compute node in another node bay to determine whether the problem remains.
  • Page 477 9. Remove the compute node from the chassis and check the connectors on the back of the node for bent pins. If the pins are bent, contact IBM Support. 10. Check http://www.ibm.com/supportportal/ for any service bulletins that are related to network connectivity.
  • Page 478 7. Check http://www.ibm.com/supportportal/ for any service bulletins that are related to I/O-module connectivity. IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 479 You can view the release notes for a firmware update to determine the issues that are addressed by the update. 6. Check http://www.ibm.com/supportportal/ for any service bulletins that are related to network connectivity. 7. (Trained service technician only) Complete the following steps: a.
  • Page 480 1. Make sure that the management node is powered on and is not hung, by logging in to the management node. If you are unable to log in from the IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 481 Multiple nodes cannot ping the management node in the same chassis: Use the information in this section to troubleshoot multiple nodes that cannot ping the IBM Flex System Manager management node in the same chassis on the data network. Action Complete the following steps until the problem is solved: 1.
  • Page 482 You can view the release notes for a firmware update to determine the issues that are addressed by the update. c. Perform a virtual reseat of the I/O module. d. Replace the I/O module. IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 483 Multiple nodes cannot ping the management node in the same chassis or a different chassis: Use the information in this section to troubleshoot multiple nodes that cannot ping the IBM Flex System Manager management node in the same chassis or a different chassis on the data network. Action Complete the following steps until the problem is solved: 1.
  • Page 484 4. Make sure that the IMM has acquired an IP address from the CMM by using the Setup utility on the compute node. IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 485 Multiple nodes cannot ping the management node in the same chassis: Use the information in this section to troubleshoot multiple nodes that cannot ping the IBM Flex System Manager management node in the same chassis on the management network. Action Complete the following steps until the problem is solved: 1.
  • Page 486 473. 6. Make sure that the management processor for each compute node has a valid IP address by checking the chassis map of the remote chassis. IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 487: Hard Disk Drive Problems

    Multiple nodes cannot ping the management node in the same chassis or a different chassis: Use the information in this section to troubleshoot multiple nodes that cannot ping the IBM Flex System Manager management node in the same chassis or a different chassis on the management network. Action Complete the following steps until the problem is solved: 1.
  • Page 488: Intermittent Problems

    Make sure that the device is configured correctly for the port (see “Using the Setup utility” on page 26). c. Run DSA Preboot USB diagnostics. IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 489: Intermittent Connectivity Problems

    Make sure that all cables and the console breakout cable are properly connected and secure. Intermittent unexpected reboots Check for an event code that indicates a reboot. See the event log for the IBM Flex System Manager management software (if installed) or see the CMM event log to determine what actions might be required to resolve this issue.
  • Page 490: Memory Problems

    Use this information to solve memory problems. Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 491: Observable Problems

    DIMM when it detected a problem, or a DIMM might have been manually disabled (see “Using the Setup utility” on page 26). 5. Run memory diagnostics (see “IBM Dynamic System Analysis Preboot diagnostic program” on page 65).
  • Page 492 If there are no events, the compute node is running within normal operating temperatures. Note that you can expect some variation in temperature. Cracked parts or cracked Contact IBM Support. chassis IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 493: Optional Device And Fru Installation Problems 481 Performance Problems

    4. Make sure that the correct device drivers are installed for the device. 5. Resolve any resource conflicts if running legacy mode (UEFI). 6. Check http://www.ibm.com/supportportal for any service bulletins. 7. Make sure that any adapter external connections are correct and that the connectors are not physically damaged.
  • Page 494: Power-On Problems

    Use this information to resolve power-on problems. Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 495: Software Problems

    Management). 4. Make sure that the IBM Flex System Manager management node has completed the discovery of the compute node. Log in to the IBM Flex System Manager user interface and verify that the compute node appears in the chassis view from the CMM.
  • Page 496: Solving Undetermined Problems

    “Removing the CMOS battery” on page 496. If you suspect that the UEFI code is corrupted, see “Recovering a UEFI image” on page 24. Check the LEDs on all the power supplies of the IBM Flex System chassis in which the compute node is installed. If the LEDs indicate that the power supplies are...
  • Page 497: Collecting Service Data

    IBM Support. You can also choose to collect data manually. This tool is integrated into the IBM Flex System Manager Service and Support Manager. All information sent to IBM is encrypted and stored in a secure IBM database and used for improved problem determination.
  • Page 498 IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 499: Installing An Optional Device

    Back up all important data before you make changes to hard disk drives. v Before you remove a compute node from the IBM Flex System chassis, you must shut down the operating system and turn off the compute node. You do not have to shut down the chassis itself.
  • Page 500: Handling Static-Sensitive Devices

    To avoid damage, keep static-sensitive devices in their static-protective packages until you are ready to install them. v When you work on a IBM Flex System chassis that has an electrostatic discharge (ESD) connector, use a wrist strap, especially when you handle modules, optional devices, or compute nodes.
  • Page 501: Removing A Compute Node From A Chassis

    39 and your operating-system documentation for additional information. Removing a compute node from a chassis Use this information to remove a compute node from a IBM Flex System chassis. Before you begin Before you remove a compute node, complete the following steps: 1.
  • Page 502: Installing A Compute Node In A Chassis

    Use this information to install a compute node in a IBM Flex System chassis. Before you begin v Before you install a IBM Flex System x440 Compute Node in a chassis that is managed by IBM Flex System Manager management software, make sure that the management software is version 1.1.1.0 or later.
  • Page 503 If you reinstall the compute node into a different node bay, you might have to reconfigure the compute node. b. To maintain proper system cooling, do not operate the IBM Flex System chassis without a compute node or node bay filler in each node bay.
  • Page 504: Removing And Replacing Tier 1 Customer Replaceable Units (Crus)

    Use this information for removing and replacing Tier 1 CRUs. About this task Replacement of Tier 1 CRUs is your responsibility. If IBM installs a Tier 1 CRU at your request, you will be charged for the installation. Removing the adapter-retention assembly Use this information to remove the adapter-retention assembly.
  • Page 505: Installing The Adapter-Retention Assembly

    1. Read “Safety” on page v and “Installation guidelines” on page 487. 2. If the compute node is installed in an IBM Flex System chassis, remove it (see “Removing a compute node from a chassis” on page 489 for instructions).
  • Page 506 Attention: Install the air baffles with the arrow indicating airflow direction pointing to the rear of the compute node. What to do next After you install the adapter-retention assembly, complete the following steps: IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 507: Removing The Bezel

    1. Install the cover onto the compute node (see “Installing the compute node cover” on page 500 for instructions). 2. Install the compute node into the chassis (see “Installing a compute node in a chassis” on page 490 for instructions). Removing the bezel Use this information to remove the bezel.
  • Page 508 1. Read “Safety” on page v and “Installation guidelines” on page 487. 2. If the compute node is installed in an IBM Flex System chassis, remove it (see “Removing a compute node from a chassis” on page 489 for instructions).
  • Page 509 1. Read “Safety” on page v and “Installation guidelines” on page 487. 2. If the compute node is installed in an IBM Flex System chassis, remove it (see “Removing a compute node from a chassis” on page 489 for instructions).
  • Page 510 1. Read “Safety” on page v and “Installation guidelines” on page 487. 2. If the compute node is installed in a IBM Flex System chassis, remove it (see “Removing a compute node from a chassis” on page 489 for instructions).
  • Page 511 CAUTION: The following label indicates a hot surface nearby. Statement 21 CAUTION: Hazardous energy is present when the compute node is connected to the power source. Always replace the compute node cover before installing the compute node. Procedure To remove the compute node cover, complete the following steps: 1.
  • Page 512 Release button Posts Slots 3. Hold the front of the compute node and slide the cover forward to the closed position, until it clicks into place. IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 513 1. Read “Safety” on page v and “Installation guidelines” on page 487. 2. If the compute node is installed in an IBM Flex System chassis, remove it (see “Removing a compute node from a chassis” on page 489 for instructions).
  • Page 514 1. Read “Safety” on page v and “Installation guidelines” on page 487. 2. Read the documentation that comes with the DIMMs. 3. If the compute node is installed in an IBM Flex System chassis, remove it (see “Removing a compute node from a chassis” on page 489 for instructions).
  • Page 515 1. Verify that the amount of installed memory is the expected amount of memory through the operating system, by watching the monitor as the compute node starts, by using the CMM sol command, or through IBM Flex System Manager management software.
  • Page 516 DR x4 49Y1415 8 GB 1333 1333 1066 RDIMM – 2Gb (1333 MHz) DR x4 49Y1415 8 GB 1600 1600 1066 RDIMM – 2Gb (1600 MHz) IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 517 Table 8. Memory Speeds and Configurations – Max Performance (continued) DIMM by rank, type, DIMM technology number capacity Speed (MHz) and Voltage Supported by DPC DR x4 49Y1565 16 GB 1333 1333 1066 RDIMM – 4Gb (1333 MHz) DR x4 00D4970 16 GB 1600...
  • Page 518 8 GB RDIMM – 2Gb (1600 MHz) DR x4 49Y1565 16 GB RDIMM – 4Gb (1333 MHz) DR x4 00D4970 16 GB RDIMM – 4Gb (1600 MHz) IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 519 Table 10. Memory Speeds and Configurations – Minimum Power (continued) DIMM by rank, type, DIMM technology number capacity Speed (MHz) and Voltage Supported by DPC QR x4 49Y1569 16 GB LR-DIMM – 2Gb (1333 MHz) QR x4 90Y3107 32 GB LR-DIMM –...
  • Page 520 DIMMs 1 and 4 DIMMs 4 and 16 DIMMs 4 and 16 DIMMs 1, 4, and 9 DIMMs 1, 4, and 16 DIMMs 4, 16, and 33 IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 521 Table 12. DIMM population sequence for independent-channel mode (continued) Number of DIMMs 1 microprocessor 2 microprocessors 4 microprocessors installed installed installed installed DIMMs 1, 4, 9, and DIMMs 1, 4, 13, and DIMMs 4, 16, 33, and DIMMs 1, 4, 9, 5, and DIMMs 1, 4, 9, 13, DIMMs 1, 4, 16, 33, and 16...
  • Page 522 9, 11, 12, 13, 14, 16, 17, 20, 21, 23, 24, 25, 28, 29, 32, 33, 35, 36, 37, 40, 41, 44, 45, 47, and 48 IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 523 Table 12. DIMM population sequence for independent-channel mode (continued) Number of DIMMs 1 microprocessor 2 microprocessors 4 microprocessors installed installed installed installed DIMMs 1, 2, 4, 5, 8, 9, 11, 12, 13, 14, 16, 17, 20, 21, 23, 24, 25, 26, 28, 29, 32, 33, 35, 36, 37, 40, 41, 44, 45, 47, and 48...
  • Page 524 19, 20, 21, 23, 24, 25, 26, 28, 29, 30, 31, 32, 33, 34, 35, 36, 37, 38, 40, 41, 42, 43, 44, 45, 46, 47, and 48 IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 525 Table 12. DIMM population sequence for independent-channel mode (continued) Number of DIMMs 1 microprocessor 2 microprocessors 4 microprocessors installed installed installed installed DIMMs 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 28, 29, 30, 31, 32, 33, 34, 35, 36, 37,...
  • Page 526 24, 25 and 28, 37 and 40, 2 and 5, 14 and 17, 32 and 35, 44 and 47, 8 and 11, 20 and 23, 26 and 29 IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 527 Table 13. DIMM population sequence for mirrored-channel mode (continued) Number of DIMM 1 microprocessor 2 microprocessor 4 microprocessor pairs installed installed installed installed DIMMs 1 and 4, 13 and 16, 33 and 36, 45 and 48, 9 and 12, 21 and 24, 25 and 28, 37 and 40, 2 and 5, 14 and 17, 32 and 35, 44...
  • Page 528 DIMM until the tabs are fully seated. When the DIMM is correctly installed, the retaining clips are parallel to the sides of the DIMM. IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 529 1. Read “Safety” on page v and “Installation guidelines” on page 487. 2. If the compute node is installed in an IBM Flex System chassis, remove it (see “Removing a compute node from a chassis” on page 489 for instructions).
  • Page 530 1. Read “Safety” on page v and “Installation guidelines” on page 487. 2. If the compute node is installed in an IBM Flex System chassis, remove it (see “Removing a compute node from a chassis” on page 489 for instructions).
  • Page 531 1. Read “Safety” on page v and “Installation guidelines” on page 487. 2. If the compute node is installed in an IBM Flex System chassis, remove it (see “Removing a compute node from a chassis” on page 489 for instructions).
  • Page 532 If you are instructed to return the hard disk drive backplane, follow all packaging instructions, and use any packaging materials for shipping that are supplied to you. IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 533 1. Read “Safety” on page v and “Installation guidelines” on page 487. 2. If the compute node is installed in an IBM Flex System chassis, remove it (see “Removing a compute node from a chassis” on page 489 for instructions).
  • Page 534 1. Press the release latch (orange) on the hard disk drive to release the drive handle. 2. Pull the release handle to remove the drive from the bay. IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 535 3. Touch the static-protective package that contains the hot-swap hard disk drive to any unpainted metal surface on the IBM Flex System chassis or any unpainted metal surface on any other grounded rack component; then, remove the hard disk drive from the package.
  • Page 536 1. Read “Safety” on page v and “Installation guidelines” on page 487. 2. If the compute node is installed in an IBM Flex System chassis, remove it (see “Removing a compute node from a chassis” on page 489 for instructions).
  • Page 537 1. Read “Safety” on page v and “Installation guidelines” on page 487. 2. If the compute node is installed in an IBM Flex System chassis, remove it (see “Removing a compute node from a chassis” on page 489 for instructions).
  • Page 538 1. Read “Safety” on page v and “Installation guidelines” on page 487. 2. If the compute node is installed in an IBM Flex System chassis, remove it (see “Removing a compute node from a chassis” on page 489 for instructions).
  • Page 539 1. Read “Safety” on page v and “Installation guidelines” on page 487. 2. If the compute node is installed in an IBM Flex System chassis, remove it (see “Removing a compute node from a chassis” on page 489 for instructions).
  • Page 540 1. Read “Safety” on page v and “Installation guidelines” on page 487. 2. If the compute node is installed in an IBM Flex System chassis, remove it (see “Removing a compute node from a chassis” on page 489 for instructions).
  • Page 541 Use this information for removing and replacing Tier 2 CRUs. About this task You may install a Tier 2 CRU yourself or request IBM to install it, at no additional charge, under the type of warranty service that is designated for the compute node.
  • Page 542 1. Read “Safety” on page v and “Installation guidelines” on page 487. 2. If the compute node is installed in an IBM Flex System chassis, remove it (see “Removing a compute node from a chassis” on page 489 for instructions).
  • Page 543 Hard disk drive backplane (see “Removing the hard disk drive backplane” on page 519). 3. The new base assembly comes with an IBM Repair Identification (RID) tag on the system board. Using a ball point pen, transfer the machine type and serial number from the old system board to the two labels on the IBM Repair Identification (RID) tag that comes with the new system board;...
  • Page 544 1. Read “Safety” on page v and “Installation guidelines” on page 487. 2. If the compute node is installed in an IBM Flex System chassis, remove it (see “Removing a compute node from a chassis” on page 489 for instructions).
  • Page 545 1. Read “Safety” on page v and “Installation guidelines” on page 487. 2. If the compute node is installed in an IBM Flex System chassis, remove it (see “Removing a compute node from a chassis” on page 489 for instructions).
  • Page 546 1. Read “Safety” on page v and “Installation guidelines” on page 487. 2. If the compute node is installed in an IBM Flex System chassis, remove it (see “Removing a compute node from a chassis” on page 489 for instructions).
  • Page 547 1. Read “Safety” on page v and “Installation guidelines” on page 487. 2. If the compute node is installed in an IBM Flex System chassis, remove it (see “Removing a compute node from a chassis” on page 489 for instructions).
  • Page 548 1. Read “Safety” on page v and “Installation guidelines” on page 487. 2. If the compute node is installed in an IBM Flex System chassis, remove it (see “Removing a compute node from a chassis” on page 489 for instructions).
  • Page 549 1. Read “Safety” on page v and “Installation guidelines” on page 487. 2. If the compute node is installed in an IBM Flex System chassis, remove it (see “Removing a compute node from a chassis” on page 489 for instructions).
  • Page 550 1. Read “Safety” on page v and “Installation guidelines” on page 487. 2. If the compute node is installed in an IBM Flex System chassis, remove it (see “Removing a compute node from a chassis” on page 489 for instructions).
  • Page 551 1. Read “Safety” on page v and “Installation guidelines” on page 487. 2. If the compute node is installed in an IBM Flex System chassis, remove it (see “Removing a compute node from a chassis” on page 489 for instructions).
  • Page 552 3. Remove the heat sink. Attention: Do not touch the thermal material on the bottom of the heat sink. Touching the thermal material will contaminate it. IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 553 a. Use a screwdriver to loosen the screw on one side of the heat sink to break the seal with the microprocessor. b. Use a screwdriver to loosen the screws on the heat sink, rotating each screw two full turns until each screw is loose. c.
  • Page 554 The architecture of the Intel Sandy Bridge-EP 4S and DMI switching of microprocessor sockets 1 and 2 allow for the processors to be populated as shown in the following figures. IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 555 Standard Configuration Mezz 1 Socket 3 Socket 1 Mezz 2 Socket 4 Socket 2 Mezz 3 Mezz 4 Figure 1. Standard Configuration Art dw1ks305 goes here. Table 14. Supported CPU installation combinations Number of Microprocessors Microprocessors Microprocessors Microprocessors microprocessors socket 1 socket 2 socket 3 socket 4...
  • Page 556 1x CPU (Socket 1 failure) Mezz 1 Socket 3 Socket 1 Mezz 2 Bad or nopop Socket 4 Socket 2 Mezz 3 Mezz 4 Figure 2. Supported one CPU configuration IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 557 2x CPU (Normal config) Mezz 1 Socket 3 Socket 1 Mezz 2 Socket 4 Socket 2 Mezz 3 Mezz 4 1x CPU Socket 1 functional but socket 1 DMI path broken Mezz 1 Socket 3 Socket 1 Mezz 2 Socket 4 Socket 2 Mezz 3 Mezz 4...
  • Page 558 1. Read “Safety” on page v and “Installation guidelines” on page 487. 2. If the compute node is installed in an IBM Flex System chassis, remove it (see “Removing a compute node from a chassis” on page 489 for instructions).
  • Page 559 This component can be installed as an optional device or as a CRU. The installation procedure is the same for the optional device and the CRU. v The optional microprocessors that IBM supports are limited by the capacity and capability of the compute node. Any microprocessors that you install must have the same specifications as the microprocessors that came with the compute node.
  • Page 560 Identify which release lever is labeled as the first release lever to open and open it. b. Open the second release lever on the microprocessor socket. c. Open the microprocessor retainer. 5. Install the microprocessor on the microprocessor socket: IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 561 Touch the static-protective bag that contains the new microprocessor to any unpainted surface on the IBM Flex System chassis or any unpainted metal surface on any other grounded rack component; then, carefully remove the microprocessor and installation tool from the package.
  • Page 562 Repeat until the screws are tight. Do not overtighten the screws by using excessive force. If you are IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 563 After you install a microprocessor and heat sink, complete the following steps: 1. Install the cover (see “Installing the compute node cover” on page 500). 2. Install the compute node in a IBM Flex System chassis (see “Installing a compute node in a chassis” on page 490 for instructions).
  • Page 564 1. Read “Safety” on page v and “Installation guidelines” on page 487. 2. If the compute node is installed in an IBM Flex System chassis, remove it (see “Removing a compute node from a chassis” on page 489 for instructions).
  • Page 565 1. Read “Safety” on page v and “Installation guidelines” on page 487. 2. If the compute node is installed in an IBM Flex System chassis, remove it (see “Removing a compute node from a chassis” on page 489 for instructions).
  • Page 566 500 for instructions). 2. Install the compute node into the chassis (see “Installing a compute node in a chassis” on page 490 for instructions). IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 567 Appendix. Getting help and technical assistance If you need help, service, or technical assistance or just want more information about IBM products, you will find a wide variety of sources available from IBM to assist you. Use this information to obtain additional information about IBM and IBM products, determine what to do if you experience a problem with your IBM system or optional device, and determine whom to call for service, if it is necessary.
  • Page 568 Secure upload with the system serial number: https://www.ecurep.ibm.com/ app/upload_hw/ Creating a personalized support web page You can create a personalized support web page by identifying IBM products that are of interest to you. IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 569 Software service and support Through IBM Support Line, you can get telephone assistance, for a fee, with usage, configuration, and software problems with your IBM products. For information about which products are supported by Support Line in your country or region, see http://www.ibm.com/services/supline/products/ .
  • Page 570 IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 571 Consult your local IBM representative for information on the products and services currently available in your area. Any reference to an IBM product, program, or service is not intended to state or imply that only that IBM product, program, or service may be used. Any functionally equivalent product, program, or service that does not infringe any IBM intellectual property right may be used instead.
  • Page 572 IBM is not responsible for replacement of a device that has exceeded its maximum guaranteed number of program/erase cycles, as documented in the Official Published Specifications for the device. IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 573 IBM makes no representations or warranties with respect to non-IBM products. Support (if any) for the non-IBM products is provided by the third party, not IBM. Some software might differ from its retail version (if available) and might not include user manuals or all program functionality.
  • Page 574 In the request, be sure to include the publication part number and title. When you send information to IBM, you grant IBM a nonexclusive right to use or distribute the information in any way it believes appropriate without incurring any obligation to you.
  • Page 575 IBM cannot accept responsibility for any failure to satisfy the protection requirements resulting from a nonrecommended modification of the product, including the fitting of non-IBM option cards. Attention: This is an EN 55022 Class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures.
  • Page 576 Telephone: +49 7032 15 2941 Email: lugi@de.ibm.com Generelle Informationen: Das Gerät erfüllt die Schutzanforderungen nach EN 55024 und EN 55022 Klasse Japan VCCI Class A statement IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 577 This is a Class A product based on the standard of the Voluntary Control Council for Interference (VCCI). If this equipment is used in a domestic environment, radio interference may occur, in which case the user may be required to take corrective actions.
  • Page 578 IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 579 RAID array 35 overview 66 configuring a RAID array 35 DSA log 67 connectivity problems 459 DSA, sending data to IBM 556 Cannot communicate with a compute connectors, system board 16 Dynamic system analysis diagnostics node 459 console breakout cable 13...
  • Page 580 487 reset to defaults 26 LAN over USB trained service technicians vi self-test error codes 458 configuring manually 48 Setup utility 26 conflicts 50 IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 581 523 specifications 4 power-on problems 482 SCSI 523 thermal grease 551 power, Setup utility 26 sending diagnostic data to IBM 556 microprocessor connector 16 problems Serial Attached SCSI (SAS) microprocessor test error codes 457 compute node start 459 hot-swap hard disk drive...
  • Page 582 565 Troubleshooting, single node cannot ping telecommunication regulatory the management node, different statement 562 chassis 468, 472 thermal grease, replacing 551 Tier 1 CRU 487 IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide...
  • Page 584 Part Number: 81Y1144 Printed in USA (1P) P/N: 81Y1144...

Table of Contents