User response:
v Replace the hard disk drives that are indicated by a lit status LED on the drive.
v Recreate the array.
v Restore data from backup.
806f060d-0406ffff
Array [ComputerSystemElementName] has failed.
Explanation: The Drive 6 is part of an RAID array that is in the failed condition. To identify drives in the failed
array all member drives will report this message.
May also be shown as 806f060d0406ffff or 0x806f060d0406ffff
Severity: Error
Alert Category: Critical - Hard Disk drive
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0176
SNMP Trap ID: 5
Automatically notify Support: Yes
User response:
v Replace the hard disk drives that are indicated by a lit status LED on the drive.
v Recreate the array.
v Restore data from backup.
806f060d-0407ffff
Array [ComputerSystemElementName] has failed.
Explanation: The Drive 7 is part of an RAID array that is in the failed condition. To identify drives in the failed
array all member drives will report this message.
May also be shown as 806f060d0407ffff or 0x806f060d0407ffff
Severity: Error
Alert Category: Critical - Hard Disk drive
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0176
SNMP Trap ID: 5
Automatically notify Support: Yes
User response:
v Replace the hard disk drives that are indicated by a lit status LED on the drive.
v Recreate the array.
v Restore data from backup.
806f070c-2001ffff
Configuration Error for [PhysicalMemoryElementName] on Subsystem
[MemoryElementName].
Explanation: This message is for the use case when an implementation has detected a Memory DIMM configuration
error has been corrected.
May also be shown as 806f070c2001ffff or 0x806f070c2001ffff
Severity: Error
Alert Category: Critical - Memory
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0126
806f060d-0406ffff • 806f070c-2001ffff
Chapter 6. Troubleshooting
225
Need help?
Do you have a question about the Flex System x440 Compute Node and is the answer not in the manual?
Questions and answers