80070617-2c01ffff • 80070617-2c03ffff
80070617-2c01ffff
Sensor Mezz Exp 1 Fault has transitioned to non-recoverable.
Explanation: A problem has been detected in the I/O expansion adapter in I/O expansion connector 1. The adapter
is unable to initialize.
May also be shown as 800706172c01ffff or 0x800706172c01ffff
Severity: Error
Alert Category: Critical - Other
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0530
SNMP Trap ID: 50
Automatically notify Support: No
User response: Complete the following steps:
1. Remove the I/O expansion adapter in I/O expansion connector 1.
2. Try to power on the chassis.
v If the chassis successfully powers on, complete the following steps:
a. Check the ServerProven website to make sure that recently installed components are compatible with the
chassis.
b. Inspect the previously installed components for physical damage.
v If the chassis does not successfully power on or if this is not the first occurrence of this problem, replace the
I/O expansion adapter.
80070617-2c02ffff
Sensor Mezz Exp 2 Fault has transitioned to non-recoverable.
Explanation: A problem was detected in the I/O expansion adapter in I/O expansion connector 2. The adapter is
unable to initialize.
May also be shown as 800706172c02ffff or 0x800706172c02ffff
Severity: Error
Alert Category: Critical - Other
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0530
SNMP Trap ID: 50
Automatically notify Support: No
User response: Complete the following steps:
1. Remove the I/O expansion adapter in I/O expansion connector 2.
2. Try to power on the chassis.
v If the chassis successfully powers on, complete the following steps:
a. Check the ServerProven website to make sure that recently installed components are compatible with the
chassis.
b. Inspect the previously installed components for physical damage.
v If the chassis does not successfully power on or if this is not the first occurrence of this problem, replace the
I/O expansion adapter.
80070617-2c03ffff
Sensor Mezz Exp 3 Fault has transitioned to non-recoverable.
Explanation: A problem was detected in the I/O expansion adapter in I/O expansion connector 3. The adapter is
unable to initialize.
May also be shown as 800706172c03ffff or 0x800706172c03ffff
Severity: Error
126
IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide