IBM Flex System x440 Compute Node Installation And Service Manual page 143

Processor-based server
Table of Contents

Advertisement

Alert Category: System - Other
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0538
SNMP Trap ID:
Automatically notify Support: No
User response: Information only; no action is required.
800b010c-2581ffff
Redundancy Lost for [RedundancySetElementName] has asserted.
Explanation: This message is for the use case when Redundancy Lost has asserted.
May also be shown as 800b010c2581ffff or 0x800b010c2581ffff
Severity: Error
Alert Category: Critical - Memory
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0802
SNMP Trap ID: 41
Automatically notify Support: No
User response: This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged
IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Information
Center for the appropriate user response.
800b030c-2581ffff
Non-redundant:Sufficient Resources from Redundancy Degraded or Fully Redundant for
[RedundancySetElementName] has asserted.
Explanation: This message is for the use case when a Redundancy Set has transitioned from Redundancy Degraded
or Fully Redundant to Non-redundant:Sufficient.
May also be shown as 800b030c2581ffff or 0x800b030c2581ffff
Severity: Warning
Alert Category: Warning - Memory
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0806
SNMP Trap ID: 43
Automatically notify Support: No
User response: This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged
IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Information
Center for the appropriate user response.
800b050c-2581ffff
Non-redundant:Insufficient Resources for [RedundancySetElementName] has asserted.
Explanation: This message is for the use case when a Redundancy Set has transitioned to Non-
redundant:Insufficient Resources.
May also be shown as 800b050c2581ffff or 0x800b050c2581ffff
Severity: Error
Alert Category: Critical - Memory
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0810
800b010c-2581ffff • 800b050c-2581ffff
Chapter 6. Troubleshooting
131

Advertisement

Table of Contents
loading

Table of Contents