80070101-0304ffff • 80070101-2c02ffff
3. Make sure that the room temperature is within operating specifications.
80070101-0304ffff
Sensor CPU 4 Overtemp has transitioned from normal to non-critical state.
Explanation: The temperature of microprocessor 4 has exceeded its specified threshold.
May also be shown as 800701010304ffff or 0x800701010304ffff
Severity: Warning
Alert Category: Warning - Temperature
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0520
SNMP Trap ID: 12
Automatically notify Support: No
User response: Complete the following steps until the problem is solved:
1. Check the Chassis Management Module or Flex System Manager event log for any fan- or cooling-related issues.
2. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are in place and
correctly installed.
3. Make sure that the room temperature is within operating specifications.
80070101-2c01ffff
Sensor Mezz Exp 1 temp has transitioned from normal to non-critical state.
Explanation: The temperature of the I/O expansion adapter in I/O expansion connector 1 has exceeded its specified
threshold.
May also be shown as 800701012c01ffff or 0x800701012c01ffff
Severity: Warning
Alert Category: Warning - Temperature
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0520
SNMP Trap ID: 12
Automatically notify Support: No
User response: Complete the following steps until the problem is solved:
1. Check the Chassis Management Module or Flex System Manager event log for any fan- or cooling-related issues.
2. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are in place and
correctly installed.
3. Make sure that the room temperature is within operating specifications.
80070101-2c02ffff
Sensor Mezz Exp 2 temp has transitioned from normal to non-critical state.
Explanation: The temperature of the I/O expansion adapter in I/O expansion connector 2 has exceeded its specified
threshold.
May also be shown as 800701012c02ffff or 0x800701012c02ffff
Severity: Warning
Alert Category: Warning - Temperature
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0520
SNMP Trap ID: 12
Automatically notify Support: No
112
IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide
Need help?
Do you have a question about the Flex System x440 Compute Node and is the answer not in the manual?