806f050d-0405ffff • 806f0513-2582ffff
SNMP Trap ID: 5
Automatically notify Support: No
User response: Replace the hard disk drive that is indicated by a lit status LED.
806f050d-0405ffff
Array [ComputerSystemElementName] is in critical condition.
Explanation: The RAID array is in critical condition. Immediate action is required to avoid a system outage.
May also be shown as 806f050d0405ffff or 0x806f050d0405ffff
Severity: Error
Alert Category: Critical - Hard Disk drive
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0174
SNMP Trap ID: 5
Automatically notify Support: No
User response: Replace the hard disk drive that is indicated by a lit status LED.
806f050d-0406ffff
Array [ComputerSystemElementName] is in critical condition.
Explanation: The RAID array is in critical condition. Immediate action is required to avoid a system outage.
May also be shown as 806f050d0406ffff or 0x806f050d0406ffff
Severity: Error
Alert Category: Critical - Hard Disk drive
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0174
SNMP Trap ID: 5
Automatically notify Support: No
User response: Replace the hard disk drive that is indicated by a lit status LED.
806f050d-0407ffff
Array [ComputerSystemElementName] is in critical condition.
Explanation: The RAID array is in critical condition. Immediate action is required to avoid a system outage.
May also be shown as 806f050d0407ffff or 0x806f050d0407ffff
Severity: Error
Alert Category: Critical - Hard Disk drive
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0174
SNMP Trap ID: 5
Automatically notify Support: No
User response: Replace the hard disk drive that is indicated by a lit status LED.
806f0513-2582ffff
A PCI SERR has occurred on system [ComputerSystemElementName].
Explanation: IMM has detected a PCI System Error (SERR) on one of these sensors: All PCI Error, One of PCI Error,
or PCIs
May also be shown as 806f05132582ffff or 0x806f05132582ffff
220
IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide
Need help?
Do you have a question about the Flex System x440 Compute Node and is the answer not in the manual?
Questions and answers