IBM Flex System x440 Compute Node Installation And Service Manual page 268

Processor-based server
Table of Contents

Advertisement

806f090c-2018ffff • 806f090c-201affff
806f090c-2018ffff
[PhysicalMemoryElementName] on Subsystem [MemoryElementName] Throttled.
Explanation: This message is for the use case when an implementation has detected Memory has been Throttled.
May also be shown as 806f090c2018ffff or 0x806f090c2018ffff
Severity: Warning
Alert Category: System - Other
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0142
SNMP Trap ID: 22
Automatically notify Support: No
User response: Complete the following steps:
1. Check the CMM or FSM event log for any fan or cooling related issues.
2. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are in place and
correctly installed.
3. Make sure that the room temperature is within operating specifications.
4. Make sure that the DIMM baffles are in place.
5. If the problem persists and there are no other DIMMs with the same indication, replace the DIMM.
806f090c-2019ffff
[PhysicalMemoryElementName] on Subsystem [MemoryElementName] Throttled.
Explanation: This message is for the use case when an implementation has detected Memory has been Throttled.
May also be shown as 806f090c2019ffff or 0x806f090c2019ffff
Severity: Warning
Alert Category: System - Other
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0142
SNMP Trap ID: 22
Automatically notify Support: No
User response: Complete the following steps:
1. Check the CMM or FSM event log for any fan or cooling related issues.
2. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are in place and
correctly installed.
3. Make sure that the room temperature is within operating specifications.
4. Make sure that the DIMM baffles are in place.
5. If the problem persists and there are no other DIMMs with the same indication, replace the DIMM.
806f090c-201affff
[PhysicalMemoryElementName] on Subsystem [MemoryElementName] Throttled.
Explanation: This message is for the use case when an implementation has detected Memory has been Throttled.
May also be shown as 806f090c201affff or 0x806f090c201affff
Severity: Warning
Alert Category: System - Other
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0142
SNMP Trap ID: 22
Automatically notify Support: No
256
IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide

Advertisement

Table of Contents
loading

Table of Contents