80070301-3701ffff
Sensor Inlet 1 Temp has transitioned to non-recoverable from a less severe state.
Explanation: The inlet 1 temperature has exceeded its specified threshold. The compute node has initiated a hard
shutdown.
May also be shown as 800703013701ffff or 0x800703013701ffff
Severity: Error
Alert Category: Critical - Temperature
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0524
SNMP Trap ID: 0
Automatically notify Support: No
User response: Complete the following steps until the problem is solved:
1. Check the Chassis Management Module or Flex System Manager event log for any fan- or cooling-related issues.
2. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are in place and
correctly installed.
3. Make sure that the room temperature is within operating specifications.
80070301-3702ffff
Sensor Inlet 2 Temp has transitioned to non-recoverable from a less severe state.
Explanation: The inlet 2 temperature has exceeded its specified threshold. The compute node has initiated a hard
shutdown.
May also be shown as 800703013702ffff or 0x800703013702ffff
Severity: Error
Alert Category: Critical - Temperature
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0524
SNMP Trap ID: 0
Automatically notify Support: No
User response: Complete the following steps until the problem is solved:
1. Check the Chassis Management Module or Flex System Manager event log for any fan- or cooling-related issues.
2. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are in place and
correctly installed.
3. Make sure that the room temperature is within operating specifications.
80070401-2c01ffff
Sensor Mezz Exp 1 temp has transitioned to non-critical from a more severe state.
Explanation: The previously high temperature of the I/O expansion adapter in I/O expansion connector 1 has
returned to below its specified threshold.
May also be shown as 800704012c01ffff or 0x800704012c01ffff
Severity: Warning
Alert Category: Warning - Temperature
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0526
SNMP Trap ID: 12
Automatically notify Support: No
User response: Information only; no action is required.
122
IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Flex System x440 Compute Node and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Table of Contents