User response: This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged
IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Information
Center for the appropriate user response.
806f0013-1701ffff
A diagnostic interrupt has occurred on system [ComputerSystemElementName].
Explanation: The user has pressed the NMI button, or the NMI button has malfunctioned.
May also be shown as 806f00131701ffff or 0x806f00131701ffff
Severity: Error
Alert Category: Critical - Other
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0222
SNMP Trap ID: 50
Automatically notify Support: No
User response: If the NMI button on the operator information panel has not been pressed, complete the following
steps:
1. Make sure that the NMI button is not pressed.
2. Replace the system board.
806f0021-2201ffff
Fault in slot [PhysicalConnectorSystemElementName] on system
[ComputerSystemElementName].
Explanation: This message is for the use case when an implementation has detected a Fault in a slot. No Op ROM
Space.
May also be shown as 806f00212201ffff or 0x806f00212201ffff
Severity: Error
Alert Category: Critical - Other
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0330
SNMP Trap ID: 50
Automatically notify Support: Yes
User response: This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged
IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Information
Center for the appropriate user response.
806f0021-2582ffff
Fault in slot [PhysicalConnectorSystemElementName] on system
[ComputerSystemElementName].
Explanation: This message is for the use case when an implementation has detected a Fault in a slot. PCIe Error.
May also be shown as 806f00212582ffff or 0x806f00212582ffff
Severity: Error
Alert Category: Critical - Other
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0330
SNMP Trap ID: 50
Automatically notify Support: Yes
User response: This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged
806f0013-1701ffff • 806f0021-2582ffff
Chapter 6. Troubleshooting
139
Need help?
Do you have a question about the Flex System x440 Compute Node and is the answer not in the manual?
Questions and answers