IBM Flex System x440 Compute Node Installation And Service Manual page 175

Processor-based server
Table of Contents

Advertisement

Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0266
SNMP Trap ID: 50
Automatically notify Support: Yes
User response:
1. Check the connections of the SAS cable between the disk and the backplane
2. (Trained service personnel only).
806f011b-1f04ffff
The connector [PhysicalConnectorElementName] has encountered a configuration error.
Explanation: The connections of the SAS cable between the SAS backplane and the planar are not complete.
May also be shown as 806f011b1f04ffff or 0x806f011b1f04ffff
Severity: Error
Alert Category: Critical - Other
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0266
SNMP Trap ID: 50
Automatically notify Support: Yes
User response:
1. Check the connections of the SAS cable between the disk and the backplane
2. (Trained service personnel only).
806f0123-2101ffff
Reboot of system [ComputerSystemElementName] initiated by IPMI Watchdog.
Explanation: The IPMI watchdog timer has expired. The compute node has restarted.
May also be shown as 806f01232101ffff or 0x806f01232101ffff
Severity: Info
Alert Category: System - Other
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0370
SNMP Trap ID:
Automatically notify Support: No
User response: Information only; no action is required.
806f0207-0301ffff
CPU 1 has Failed with FRB1/BIST condition.
Explanation: This message is for the use case when an implementation has detected a Processor Failed - FRB1/BIST
condition.
May also be shown as 806f02070301ffff or 0x806f02070301ffff
Severity: Error
Alert Category: Critical - CPU
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0044
SNMP Trap ID: 40
Automatically notify Support: No
806f011b-1f04ffff • 806f0207-0301ffff
Chapter 6. Troubleshooting
163

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Flex System x440 Compute Node and is the answer not in the manual?

Questions and answers

Table of Contents