2. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are in place and
correctly installed.
3. Make sure that the room temperature is within operating specifications.
4. Make sure that the DIMM baffles are in place.
5. If the problem persists and there are no other DIMMs with the same indication, replace the DIMM.
806f0a13-2401ffff
A Fatal Bus Error has occurred on bus [SensorElementName].
Explanation: IMM has detected a Bus Fatal Error relating to SMBus.
May also be shown as 806f0a132401ffff or 0x806f0a132401ffff
Severity: Error
Alert Category: Critical - Other
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0244
SNMP Trap ID: 50
Automatically notify Support: No
User response: This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged
IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Information
Center for the appropriate user response.
806f0a13-2582ffff
A Fatal Bus Error has occurred on bus [SensorElementName].
Explanation: IMM has detected a Bus Fatal Error relating to PCI.
May also be shown as 806f0a132582ffff or 0x806f0a132582ffff
Severity: Error
Alert Category: Critical - Other
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0244
SNMP Trap ID: 50
Automatically notify Support: No
User response: This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged
IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Information
Center for the appropriate user response.
806f0b13-0701ffff
Bus [SensorElementName] is operating in a degraded state.
Explanation: IMM has detected that the DMI Bus is degraded.
May also be shown as 806f0b130701ffff or 0x806f0b130701ffff
Severity: Warning
Alert Category: Warning - Other
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0246
SNMP Trap ID: 60
Automatically notify Support: No
User response: Complete the following steps:
1. AC cycle the machine
806f0a13-2401ffff • 806f0b13-0701ffff
Chapter 6. Troubleshooting
289
Need help?
Do you have a question about the Flex System x440 Compute Node and is the answer not in the manual?
Questions and answers