3.
Move card to a different slot. If slot not available or error re-occurs, replace adapter.
4.
(Trained Service technician only) If adapter was moved to a different slot and error did not re-occur, verify that
this is not a system limitation and then replace the system board. Also, if this is not the initial installation and the
error persists after adapter replacement, replace system board.
I.2018003
[I.2018003] A bad option ROM checksum was detected for the device found at Bus % Device %
Function %. The Vendor ID for the device is % and the Device ID is %.
Explanation: ROM CHECKSUM ERROR
Severity: Info
User response: Complete the following steps:
1.
If this PCIe device and/or any attached cables were recently installed, moved, serviced or upgraded, reseat
adapter and any attached cables.
2.
Move adapter to a different system slot, if available.
3.
Check IBM support site for any applicable service bulletin or UEFI or adapter firmware update that applies to
this error. NOTE: It may be necessary to configure slot to Gen1 or to use special utility software so that adapter
firmware can be upgraded. Gen1/Gen2 settings can be configured via F1 Setup -> System Settings -> Devices and
I/O Ports -> PCIe Gen1/Gen2/Gen3 Speed Selection, or the ASU Utility.
4.
Replace adapter.
I.3048005
[I.3048005] UEFI has booted from the backup flash bank.
Explanation: Booting Backup UEFI Image
Severity: Info
User response: Complete the following step:
Refer to service information for this product section on UEFI Recovery to return system to primary bank.
I.3808004
[I.3808004] The IMM System Event log (SEL) is full.
Explanation: IPMI System Event Log is Full
Severity: Info
User response: Complete the following steps:
1.
Use IMM Web Interface to clear event log.
2.
If IMM communication is unavailable, use F1 Setup to access System Event Logs Menu and Choose Clear IMM
System Event Log and Restart Server.
I.3818001
[I.3818001] The firmware image capsule signature for the currently booted flash bank is invalid.
Explanation: Current Bank CRTM Capsule Update Signature Invalid
Severity: Info
User response: Complete the following steps:
1.
Reboot system. Will come up on backup UEFI image. Reflash the primary UEFI image.
2.
If error does not persist no additional recovery action is required.
3.
If error persists, or boot is unsuccessful, (Trained service technician only) Replace the system board.
I.3818002
[I.3818002] The firmware image capsule signature for the non-booted flash bank is invalid.
Explanation: Opposite Bank CRTM Capsule Update Signature Invalid
Severity: Info
User response: Complete the following steps:
1.
Reflash backup UEFI image.
I.2018003 • I.3818002
Chapter 6. Troubleshooting
445
Need help?
Do you have a question about the Flex System x440 Compute Node and is the answer not in the manual?
Questions and answers