Chapter 5 - Power Chassis Installation
To Install Mounting Brackets:
• Remove (and discard) 3 existing countersunk
screws from side of chassis at locations shown
in drawing.
• Place bracket in desired position and secure
with indicated M4 pan-head screws and washers from
accessories kit.
• Repeat process for other side of chassis. If the
amp chassis is joined to an Adept MV controller,
the position of the screws is different on the side
of the controller. See the Adept MV Controller
User's Guide for information.
Note: See Appendix A for dimensions of the
chassis and mounting brackets.
M4 x 25mm pan-head screw
(2 places)
M4 x 10mm pan-head screw
Rack Mount – Flush
38
Adept 550 Table-Top Robot User's Guide, Rev A
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Installing Mounting Brackets
Figure 5-4.
M4 x 25mm pan-head screw
(2 places)
M4 x 10mm pan-head screw
Panel Mount
M4 x 25mm pan-head screw
(2 places)
M4 x 10mm pan-head screw
Rack Mount – Set-Back