Emc Shield; Brake Terminal Block (Optional) - Danfoss VLT FC Series Service Manual

Hide thumbs Also See for VLT FC Series:
Table of Contents

Advertisement

D2h/D4h/D7h/D8h/J9 Unit Dis...

11.2.7 EMC Shield

To remove or reinstall the EMC shield, use the following
steps. See Illustration 11.4.
Disassembly
1.
Remove 1 screw (T20) from the EMC shield.
2.
Remove the EMC shield from the drive.
Reassembly
Tighten fasteners according to chapter 14.1 Fastener Torque
Ratings.
1.
Position the EMC shield in the drive.
2.
Secure 1 screw (T20) in the EMC shield.
11
11
196
®
VLT
FC Series, D1h–D8h, Da2/Db2/Da4/Db4, E1h–E4h, J8/J9

11.2.8 Brake Terminal Block (Optional)

Drives can include an optional brake. To remove or reinstall
the optional brake terminal block, use the following steps.
Refer to Illustration 11.3.
Disassembly
1.
2.
3.
4.
Reassembly
Tighten fasteners according to chapter 14.1 Fastener Torque
Ratings.
1.
2.
3.
4.
Danfoss A/S © 02/2019 All rights reserved.
Disconnect the brake wiring.
To remove the R(+) terminal:
2a
Remove 1 thread-forming screw (T25)
from the terminal block.
2b
Remove 1 screw (T40).
To remove the R(-) terminal:
3a
Remove 1 thread-forming screw (T25)
from the terminal block.
3b
Remove 1 nut (13 mm).
Remove the brake terminal block by removing 2
nuts (13 mm).
Position the brake terminal block in the drive and
secure 2 nuts (13 mm).
To attach the R(-) terminal:
2a
Fasten 1 thread-forming screw (T25) in
the terminal block.
2b
Fasten 1 nut (13 mm).
To attach the R(+) terminal:
3a
Fasten 1 thread-forming screw (T25) in
the terminal block.
3b
Secure 1 screw (T40).
Reconnect the brake wiring.