The following digital/analog inputs/outputs are available:
Table 14-6
Component
CU320-2
CU310-2
TB30
TM15
TM31
TM41
TM120
Adjustable: floating or non-floating
1)
Six of these are "high-speed inputs"
2)
Additional inputs for Safety Integrated Basic Functions
3)
Note
Detailed information on the hardware properties of the inputs/outputs can be found in the
SINAMICS S120 Control Units Manual.
For detailed information about the structural relationships between all I/Os of a component and
their parameters, please refer to the function diagrams in the SINAMICS S120/S150 List
Manual:
14.6.1

Digital inputs/outputs

Signal processing using the digital inputs is shown in the function diagrams listed below.
Properties
● The digital inputs are "high active".
● An open input is interpreted as "low".
● Fixed debounce setting.
Delay time = 1 to 2 current controller cycles (p0115[0])
● Availability of the input signal for further interconnection.
– Inverted and not inverted as a binector output
– As a connector output
798
Overview of inputs/outputs
Inputs
Bidirectional in‐
12
1)
5+3
3)
4
-
8
Relay outputs: 2
Temperature sensor input: 1
4
Incremental encoder emulation: 1
Temperature sensor inputs: 4
Digital
Outputs
puts/outputs
8
-
2)
8+1
-
3)
-
4
24
-
4
-
4
-
Function Manual, 06/2019, 6SL3097-5AB00-0BP2
Analog
Inputs
Outputs
-
-
1
-
2
2
-
-
2
2
1
-
Drive functions