Basic information about the drive system
14.4 BICO technology: Interconnecting signals
14.4.3

Internal coding of the binector/connector output parameters

Internal coding is required for writing BICO input parameters via PROFIBUS, for example.
Figure 14-9
14.4.4

Sample interconnections

Example 1: Interconnection of digital signals
Suppose you want to operate a drive via terminals DI 0 and DI 1 on the Control Unit using jog
1 and jog 2.
Figure 14-10
Example 2: Connection of OC/OFF3 to several drives
The OFF3 signal should be connected to two drives via terminal DI 2 on the Control Unit.
Each drive has the two binector inputs, "1st OFF3" and "2nd OFF3". The two signals are
processed via an AND gate to STW1.2 (OFF3).
788
Internal coding of the binector/connector output parameters
Interconnection of digital signals (example)
Function Manual, 06/2019, 6SL3097-5AB00-0BP2