Web server
13.2 Fundamentals
PROFINET interface X150 is preset as follows:
● Accessing the web server
Access via the PROFINET interface is deactivated as default setting in the web server.
● Communication
Communication via the PROFINET interface is always established via the secure HTTPS
connection.
Note
Security measures for communication via PROFINET
In accordance with the Defense in Depth concept, PROFINET must be isolated from the
remaining plant or system network (see Industrial security (Page 27)). Access to cables and
possibly open connections must be implemented in a protected fashion, such as in a control
cabinet.
13.2.2.3

Preparations

1. Connect the converter to your commissioning device (PG/PC, tablet or smartphone) via
service interface X127.
2. Switch the converter on.
The converter starts up.
3. Start the browser in your commissioning device.
4. Enter the standard IP address (169.254.11.22) of the converter in the input line of your
browser.
13.2.2.4

Interfaces and connection type

Using the default configuration of the web server, you can access the SINAMICS frequency
converter using the service interface X127, both via an HTTP connection as well as via an
encrypted HTTPS connection.
In the standard configuration, interface X150 is deactivated for web server access operations,
and can be activated using parameter p8984[1] If interface X150 is activated for access to the
web server, then as default setting, access can only be established via a secure HTTPS
connection (see Chapter "Configuring the IP connection (Page 759)").
Parameter p8984[1] is a BICO parameter. This means that interface X150 can also be activated
for web server access via a key-operated switch.
NOTICE
Software manipulation when using non-encrypted connections (HTTP)
The HTTP protocol transfers data without encryption. This facilitates password theft, for
example, and can lead to data manipulation by unauthorized parties and thus to damage.
● Limit access to HTTPS connections so that all data is transferred in encrypted form.
718
Function Manual, 06/2019, 6SL3097-5AB00-0BP2
Drive functions