Pre-Assignment Of The Inputs And Outputs - Siemens SINAMICS G120 CU240B-2 Operating Instructions Manual

With the control units
Hide thumbs Also See for SINAMICS G120 CU240B-2:
Table of Contents

Advertisement

Commissioning
4.3 Commissioning with factory settings
4.3.3

Pre-assignment of the inputs and outputs

Terminal strip factory settings
Terminal
Abbreviation
5
DI0
6
DI1
7
DI2
8
DI3
16
DI4
17
DI5
Terminal
Abbreviation
18
NC
DO0
19
NO
20
COM
21
NO
DO1
22
COM
23
NC
DO2
24
NO
25
COM
Terminal
Abbreviation
3
AI0+
AI0
4
AI0-
In the factory setting, analog input 0 supplies the speed setpoint.
10
AI1+
AI1
11
AI1-
62
Parameter
Factory setting
P0701
1 or 0
P0702
12 or 0
P0703
9
P0704
15
P0705
16
P0706
17
Digital outputs (relay outputs)
Parameter
Factory setting
P0730
52.3
P0731
52.7
P0732
52.2
Analog inputs
Parameter
Factory setting
P0756 [0]
4
P0756 [1]
4
Digital inputs
Meaning of the factory setting
ON/OFF1
Direction reversal
Fault acknowledgment
Fixed frequency selector bit 0 (direct) [P1001]
Fixed frequency selector bit 1 (direct) [P1002]
Fixed frequency selector bit 2 (direct) [P1003]
Meaning of the factory setting
Drive fault active
Drive alarm active
Operation enabled
Meaning of the factory setting
Set bipolar voltage input
-10 V ... +10 V DC
in addition to parameterizing DIP switch on CU housing.
Set bipolar voltage input
-10 V ... +10 V DC
in addition to parameterizing DIP switch on CU housing.
Inverter with CU240B-2 and CU240E-2 Control Units
Operating Instructions, 07/2010, FW 4.3.2, A5E02299792B AA