4.4

Speed limiting

Function description
In the range from 0 rpm to the speed setpoint, a drive train (e.g. motor, clutch, shaft, machine)
can have one or more points of resonance. These resonances lead to oscillations. The
suppression bandwidths can be used to prevent operation in the resonant frequency range.
The limit frequencies can be set via p1080[D] and p1082[D]. Further, using connectors
p1085[C] and p1088[C] it is possible to influence these limits in operation.
Figure 4-7
Minimum speed
Using parameter p1106[0...n], a minimum speed n_min s_src or minimum velocity can be set,
which is wired via BICO.
Function diagrams (see SINAMICS S120/S150 List Manual)
● 3001
● 3050
Drive functions
Function Manual, 06/2019, 6SL3097-5AB00-0BP2
Skip frequency bands, setpoint limitation, minimum speed
Setpoint channel overview
Setpoint channel - Skip frequency bands and speed limiting
Extended setpoint channel
4.4 Speed limiting
71