Terminal Modules - Siemens SINAMICS S120 Function Manual

Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

10.2.4

Terminal Modules

Terminal Modules provided the drive system with additional analog and digital data inputs and
outputs. They are intended for use in control cabinets. The Terminal Modules are connected via
DRIVE-CLiQ with the drive system. Terminal Modules TM31, TM120 and TM150 provide
inputs for temperature sensors.
● The TM31 can evaluate one temperature sensor.
● The TM120 can evaluate up to 4 temperature sensors. The sensor inputs have protective
separation.
● The TM150 can evaluate up to 12 sensors. The sensors can be split up into a maximum of
3 groups. Each sensor can be freely assigned to one of the group.
Table 10-5
Device
TM31
TM120
TM150
) You will find more detailed information on sensor connections in the chapter on "Terminal Module
1
150".
Drive functions
Function Manual, 06/2019, 6SL3097-5AB00-0BP2
Temperature sensor connection
Interface
Chan‐
nel
X522
0
X521
0
1
2
3
X531
0
1)
X532
1
1)
X533
2
1)
X534
3
1)
X535
4
1)
X536
5
1)
Monitoring functions and protective functions
+Tem
-Temp Temperature sensor type
p
7
8
KTY84/PTC/PT1000
2
1
KTY84-1C130/PTC/PT1000/bimetallic NC con‐
tact,
Linear motor: KTY84-1C130/PT1000
4
3
KTY84-1C130/PTC/PT1000/bimetallic NC con‐
tact,
Linear motor: KTY84-1C130/PT1000
6
5
KTY84-1C130/PTC/PT1000/bimetallic NC con‐
tact,
Linear motor: KTY84-1C130/PT1000
8
7
KTY84-1C130/PTC/PT1000/bimetallic NC con‐
tact,
Linear motor: KTY84-1C130/PT1000
1
2
KTY84-1C130/PTC/bimetallic NC contact/
3
4
PT100/PT1000
1
2
KTY84-1C130/PTC/bimetallic NC contact/
3
4
PT100/PT1000
1
2
KTY84-1C130/PTC/bimetallic NC contact/
3
4
PT100/PT1000
1
2
KTY84-1C130/PTC/bimetallic NC contact/
3
4
PT100/PT1000
1
2
KTY84-1C130/PTC/bimetallic NC contact/
3
4
PT100/PT1000
1
2
KTY84-1C130/PTC/bimetallic NC contact/
3
4
PT100/PT1000
10.2 Thermal motor protection