13.4
Creating and adjusting the parameter list
13.4.1
Overview
In the web server, you can manage up to 20 parameter lists with 40 parameters each. The
created parameter lists are saved on the memory card of the drive. As a result, created
parameter lists are available for further access even after the drive is switched off.
13.4.2
Creating a parameter list
To create a parameter list, proceed as follows:
1. Click the "Parameter" entry in the navigation.
Then the "Parameter" display area and the "No list available" tab are shown.
2. In order to create a list, click on the "Create list" tab.
The "Create user-defined parameter list" dialog opens.
3. In the "Name of the list" entry field, enter a name of the parameter list.
Note
When entering names for parameter lists, do not use any special characters (e.g. ?!%+).
4. In the "Position" drop-down list, select a position for the parameter list.
If needed, you can change the order of the tabs in the "Parameters" display area (see the
"Changing the list properties (Page 750)" chapter).
Drive functions
Function Manual, 06/2019, 6SL3097-5AB00-0BP2
13.4 Creating and adjusting the parameter list
Web server
747