Important notes regarding a firmware update
Note
When upgrading to higher firmware versions, the project data are kept. When downgrading to
lower firmware versions, the converter is reset to the factory settings. In this case, project data
are lost.
Note
From firmware version ≥ V4.6, data on the working partition is duplicated to a backup partition
to guarantee that when upgrading via the web server, data is protected and not lost if the power
fails. This ensures that when updating data on the memory card no data is lost if a fault situation
occurs.
Note
Backing up web server settings
In order that your specific web server settings remain after upgrading the firmware, before
upgrading, backup the configuration data and then load them again after the upgrade has been
completed. The data should be backed up in this memory card directory: \OEM\SINAMICS\HMI
\.
Further information
Additional information is provided in the SINAMICS S120 Commissioning Manual and in the
Startdrive information system.
Available firmware versions
You can find the available firmware versions at the following link: Firmware versions
support.industry.siemens.com/cs/ww/en/view/109744577).
13.6.6.2

Updating the firmware and STARTER project files

Requirements
You have saved the zip file with the firmware to a drive, which you can access using the
commissioning device (PG/PC, tablet or smartphone).
Drive functions
Function Manual, 06/2019, 6SL3097-5AB00-0BP2
Web server
13.6 System settings
(https://
765