Procedure
1. Click "Reset all filters" at the top right in the filter bar.
You have now re-set all configured filters. The event list then displays the unfiltered view of
the operating events again.
13.3.4

"Communication" display area

In order to call up the "Communication" display area, proceed as follows:
Procedure
1. Select "Diagnostics > Communication" in the navigation.
The web server shows a window with the following contents:
– IP address of the converter
– Name of the station
– Information as to whether the connection between the controller and the converter is
– Table with process data for the transfer direction "controller > converter"
– Table with process data for the transfer direction "converter > controller"
Figure 13-24
The values are displayed in hexadecimal format in the default setting. You can switch the
display of individual values between binary and hex format by clicking on the button to the right
of the value.
13.3.5

"Trace files" display area

The web server permits the loading of trace files that were created using a multiple trace and
stored on the memory card of the drive. All the files in the "USER/SINAMICS/DATA/TRACE"
directory of the memory card can be loaded to the web client (i.e. to the PC). The loadable trace
files are displayed on the web page with their name.
Drive functions
Function Manual, 06/2019, 6SL3097-5AB00-0BP2
active.
Example: Communication display area
Web server
13.3 Diagnostic functions
745