Extended setpoint channel
4.3 Speed setpoint
4.3.3

Direction of rotation limiting and direction reversal

Function description
A reversing operation involves a direction of rotation reversal. Selecting setpoint inversion
p1113[C] can reverse the direction of rotation in the setpoint channel.
Parameter p1110[C] or p1111[C] can be set respectively to prevent input of a negative or
positive setpoint via the setpoint channel. However, the following settings for minimum speed
(p1080) in the setpoint channel are still operative. With the minimum speed, the motor can turn
in a negative direction, although p1110 = 1 is set.
Figure 4-6
Function diagrams (see SINAMICS S120/S150 List Manual)
● 3001
● 3040
Overview of important parameters (see SINAMICS S120/S150 List Manual)
● p1110[0...n]
● p1111[0...n]
● p1113[0...n]
70
Direction of rotation limiting and direction of rotation reversal
Setpoint channel overview
Setpoint channel - Direction limitation and direction reversal
BI: Block negative direction
BI: Block positive direction
BI: Setpoint inversion
Function Manual, 06/2019, 6SL3097-5AB00-0BP2
Drive functions