If your system includes USB flash drive that have already been successfully
initialized, then after the control enclosure system IP address has been changed, it
is necessary to ensure that the USB flash drive record of the address matches.
Updating file module's record of the control enclosure system IP:
To find the USB flash drive current record of the control enclosure system IP
address, use the Storwize V7000 Unified management CLI to issue the
lsstoragesystem command. Here is an example:
>ssh admin@<management_IP>
[kd01ghf.ibm]$ lsstoragesystem
name
StorwizeV7000 9.11.137.130 9.11.137.130 00000200A2601508
EFSSG1000I The command completed successfully.
If the primary and secondary IP address shown by the lsstoragesystem CLI do
not match the system IP addresses then it is necessary to update the record. The
chstoragesystem command changes the file module record of the control enclosure
system IP. Here is an example:
>[kd01ghf.ibm]$ chstoragesystem --ip1 9.71.18.136 --ip2 9.71.18.136
EFSSG1000I The command completed successfully.
Verify that communication from the file module to the control enclosure is now
possible by running the lssystemip command on the Storwize V7000 Unified
management CLI:
>ssh admin@v7000-unified
[kd01ghf.ibm]$ lssystemip

Problem: Management IP address unknown

This topic helps you if you are not able to run the management GUI because you
do not know the IP address. This address is also known as the management IP
address.
This topic also helps if the configuration communication between the file system
(file modules) and the control enclosure is not working because the wrong IP
address is being used.
The management IP address is set when the USB initialization is completed. An
address for port 2 can be added later.

Problem: Unable to connect to the management GUI

If you are unable to connect to the management GUI from your web browser and
received a Page not found or similar error, this information might help you resolve
the issue.
Consider the following possibilities if you are unable to connect to the
management GUI:
v You cannot connect if the system is not operational with at least one node
204
Storwize V7000 Unified: Problem Determination Guide Version
primaryIP
online. If you know the service address of a node canister, go to "Procedure:
Getting node canister and system information using the service assistant" on
page 212; otherwise, go to "Procedure: Getting node canister and system
information using a USB flash drive" on page 213 and obtain the state of each of
the node canisters from the data that is returned. If there is not a node canister
with a state of active, resolve the reason why it is not in active state. If the state
secondaryIP id