7. Replace the DIMM air baffle, as described in "Installing the DIMM air baffle"
on page 99.
8. Install the cover, as described in "Installing the cover" on page 88.
9. Slide the file module into the rack.
10. Reconnect the external cables; then, reconnect the power cords and turn on
the peripheral devices and the file module.
Note: You must wait approximately 2.5 minutes after you connect the power
cord of the file module to an electrical outlet before the power-control button
becomes active.
Removing the IBM virtual media key
The following procedure is for a Tier 1 customer replaceable unit (CRU).
Replacement of Tier 1 CRUs is your responsibility. If IBM installs a Tier 1 CRU at
your request, you will be charged for the installation. Service agreements can be
purchased so that you can ask IBM to replace these units.
About this task
Note: Before running a procedure, refer to "Removing a file module to perform a
maintenance action" on page 55.
To remove a virtual media key, complete the following procedure.
Procedure
1. To help you work safely with Storwize V7000 Unified file module, read the
safety information in "Safety" on page xi, "Safety statements" on page xiii, and
"Installation guidelines" on page 58.
2. Turn off the file module and peripheral devices, then label and disconnect both
power cords and all external cables.