System Board Fan Locations - IBM Storwize V7000 Unified Problem Determination Manual

Table of Contents

Advertisement

The fans use system-board fan connectors 2, 4, and 6 only. The following table lists
the fan connector on the system board for each double-fan. See "System-board
internal connectors" in the IBM Storwize V7000 Unified Information Center for the
locations of the fan connectors.
Table 31. System board fan locations
Fan number
1
2
3
To install any of the three replaceable fans, complete the following steps.
Procedure
1. To help you work safely with Storwize V7000 Unified file module, read the
safety information in "Safety" on page xi, "Safety statements" on page xiii, and
"Installation guidelines" on page 58.
2. Orient the new fan over its position in the fan bracket so that the connector on
the bottom aligns with the fan connector on the system board.
3. Align the vertical tabs on the fan with the slots on the fan cage bracket.
4. Push the new fan into the fan connector on the system board. Press down on
the top surface of the fan to seat the fan fully.
5. Repeat until all the new or replacement fans are installed.
6. Install the cover, as described in "Installing the cover" on page 88.
7. Slide the file module into the rack.
Removing a hot-swap ac power supply
The following procedure is for a Tier 1 customer replaceable unit (CRU).
Replacement of Tier 1 CRUs is your responsibility. If IBM installs a Tier 1 CRU at
your request, you will be charged for the installation. Service agreements can be
purchased so that you can ask IBM to replace these units.
System board fan connector
2
4
6
Chapter 4. File module
143

Advertisement

Table of Contents
loading