IBM Storwize V7000 Unified Problem Determination Manual page 42

Table of Contents

Advertisement

18
Storwize V7000 Unified: Problem Determination Guide Version
Table 6. Error messages and actions (continued)
Error code
Error message
0B5A
Unable to determine management IP address of this
node.
0B5B
Unknown node type.
0B5C
IP address conflict detected with the management IP.
There is a node that already has this IP address.
0B5E
IP address conflict detected with its peer
management IP. There is a node that already has this
IP address.
0B5F
Error updating node's data in newnodes.dat.
0B60
Error writing temporary file.
0B62
Node did not finish configuration before timeout.
0B7F
All nodes must be up before adding a new node.
0B80
Unable to find the peer storage node.
0B81
The host name was not set properly.
0B82
Unable to create temp file nodes.lst.
0B85
Error copying cluster configuration to node.
0B86
Error restoring cluster configuration on node.
0B87
There was an error while adding nodes to the GPFS
cluster.
0B88
There was an error while configuring GPFS licensing. A
0B89
There was an error while configuring GPFS quorum.
0B8C
There was an error in updating the configuration on
the new node.
0B8D
Error reading checkpoint file.
0B8E
Error writing to checkpoint file.
0B8F
There was an error while installing GPFS callbacks.
0B92
Rsync failed between management nodes.
0B94
There were too many potential peer storage nodes.
Storage controllers may be cabled incorrectly or
UUIDs might not be set properly.
0B95
Invalid parameters.
0B96
Failed to configure the management processes on
mgmt001st001
0B97
IP is invalid.
0B98
Netmask is invalid.
Action key
A
B
D
D
B
A
B
A
Check Fibre Channel
cabling between the
file modules and the
control enclosure.
Verify that the control
enclosure is up. Refer
to "Powering the
system on and off" in
the IBM Storwize
V7000 Unified
Information Center.
A
A
A
A
A
A
A
A
A
A
C
A
D
D then A then B
D
D

Advertisement