Attention:
v When you route cables, do not block any connectors or the ventilated space
around any of the fans.
v Make sure that cables are not routed on top of components under the PCI
riser-card assemblies.
v Make sure that cables are not pinched by server components.
6. Install the cover, as described in "Installing the cover" on page 88.
7. Slide the file module into the rack.
8. Reconnect the external cables; then, reconnect the power cords and turn on the
peripheral devices and the file module.
Note: You must wait approximately 2.5 minutes after you connect the power
cord of the file module to an electrical outlet before the power-control button
becomes active.
9. Start the Setup utility and reset the configuration.
v Set the system date and time.
v Set the power-on password.
v Reconfigure the file module.
Removing the microprocessor 2 air baffle
The following procedure is for a Tier 1 customer replaceable unit (CRU).
Replacement of Tier 1 CRUs is your responsibility. If IBM installs a Tier 1 CRU at
your request, you will be charged for the installation. Service agreements can be
purchased so that you can ask IBM to replace these units.
About this task
Note: Before running a procedure, refer to "Removing a file module to perform a
maintenance action" on page 55.
When you work with some optional devices, you must first remove the
microprocessor 2 air baffle to access certain components on the system board.
To remove the microprocessor 2 air baffle, complete the following steps.
95
Chapter 4. File module