Installing the 240 VA safety cover
The following procedure is for a field replaceable unit (FRU). FRUs must be
installed only by trained service technicians.
About this task
To install the 240 VA safety cover, perform the following steps:
Procedure
1. Line up and insert the tabs on the bottom of the safety cover into the slots on
Screw
Safety cover
Alignment
tabs
Figure 45. 240 VA safety cover
2. Slide the safety cover toward the back of the server until it is secure.
3. Connect the hard disk drive backplane power cables to the connector in front
4. Install the screw into the safety cover.
5. Install the SAS riser-card assembly.
6. Install the server cover.
7. Slide the server into the rack.
8. Reconnect the external cables, then reconnect the power cords and turn on the
Setting the machine type, model, and serial number
The following procedure is for a field replaceable unit (FRU). FRUs must be
installed only by trained service technicians.
About this task
The ASU package is part of the Storwize V7000 Unified code. ASU is available to
authorized service personnel from the command-line interface (CLI) on the file
module. Use ASU to modify selected settings in the integrated-management-
module (IMM)-based Storwize V7000 Unified file modules.
the system board. See Figure 45.
of the safety cover.
peripheral devices and the server.