IBM Storwize V7000 Unified Quick Installation Manual

Advertisement

IBM Storwize V7000 Unified
Model 2073-720 Quick Installation
Guide
GC27-5945-01

Advertisement

Table of Contents
loading

Summary of Contents for IBM Storwize V7000 Unified

  • Page 1 IBM Storwize V7000 Unified Model 2073-720 Quick Installation Guide GC27-5945-01...
  • Page 2 Before using this information and the product it supports, read the general information in “Notices” on page 73, the information in the “Safety and environmental notices” on page iii, as well as the information in the IBM Environmental Notices and User Guide , which is provided on a DVD.
  • Page 3: Safety And Environmental Notices

    In the preceding examples, the numbers (C001) and (D002) are the identification numbers. 2. Locate IBM Systems Safety Notices with the user publications that were provided with the Storwize V7000 Unified hardware. 3. Find the matching identification number in the IBM Systems Safety Notices. Then review the topics concerning the safety notices to ensure that you are in compliance.
  • Page 4 “Labels” section. The following notices and statements are used in IBM documents. They are listed in order of decreasing severity of potential hazards. Danger notice definition A special note that emphasize a situation that is potentially lethal or extremely hazardous to people.
  • Page 5 CAUTION: Electrical current from power, telephone, and communication cables can be hazardous. To avoid personal injury or equipment damage, disconnect the attached power cords, telecommunication systems, networks, and modems before you open the machine covers, unless instructed otherwise in the installation and configuration procedures.
  • Page 6 It is intended that equipment installed within this rack will have its own enclosure. (R005). CAUTION: Tighten the stabilizer brackets until they are flush against the rack. (R006) CAUTION: Use safe practices when lifting. (R007) IBM Storwize V7000 Unified: Model 2073-720 Quick Installation Guide...
  • Page 7 (R009) Danger notices for Storwize V7000 Unified Ensure that you are familiar with the danger notices for Storwize V7000 Unified. Use the reference numbers in parentheses at the end of each notice, such as (C003) for example, to find the matching translated notice in IBM Systems Safety Notices.
  • Page 8 Electrical voltage and current from power, telephone, and communication cables are hazardous. To avoid a shock hazard: v If IBM supplied a power cord(s), connect power to this unit only with the IBM provided power cord. Do not use the IBM provided power cord for any other product.
  • Page 9 Observe the following precautions when working on or around your IT rack system: v Heavy equipment–personal injury or equipment damage might result if mishandled. v Always lower the leveling pads on the rack cabinet. v Always install stabilizer brackets on the rack cabinet. v To avoid hazardous conditions due to uneven mechanical loading, always install the heaviest devices in the bottom of the rack cabinet.
  • Page 10: General Safety

    General safety When you service the Storwize V7000 Unified, follow general safety guidelines. Use the following general rules to ensure safety to yourself and others: v Observe good housekeeping in the area where the devices are kept during and after maintenance.
  • Page 11 Attention: Depending on local conditions, the sound pressure can exceed 85 dB(A) during service operations. In such cases, wear appropriate hearing protection. Environmental notices This publication contains all the required environmental notices for IBM Systems products in English and other languages. Safety and environmental notices...
  • Page 12 To view a PDF file, you need Adobe Reader. You can download it at no charge from the Adobe web site (get.adobe.com/reader/). IBM Storwize V7000 Unified: Model 2073-720 Quick Installation Guide...
  • Page 13: About This Guide

    Storwize V7000 Unified library Unless otherwise noted, the publications in the Storwize V7000 Unified library are available in Adobe portable document format (PDF) from the following website: www.ibm.com/e-business/linkweb/publications/servlet/pbi.wss The following table lists websites where you can find help, services, and more information: Table 1.
  • Page 14 Storwize V7000 Unified documentation has a number that you can use to locate the corresponding statement in your language in the IBM Storwize V7000 Unified Safety Notices document. IBM Storwize V7000 Unified: Model 2073-720 Quick Installation Guide...
  • Page 15 Storwize V7000 Unified storage environment. IBM documentation and related websites Table 3 on page xvi lists websites that provide publications and other information about the Storwize V7000 Unified or related products or technologies. About this guide...
  • Page 16 Some publications are available for you to view or download at no charge. You can also order publications. The publications center displays prices in your local currency. You can access the IBM Publications Center through the following website: www.ibm.com/e-business/linkweb/publications/servlet/pbi.wss...
  • Page 17 Before calling for support, be sure to have your IBM Customer Number available. If you are in the US or Canada, you can call 1 (800) IBM SERV for help and service. From other parts of the world, see http://www.ibm.com/planetwide for the number that you can call.
  • Page 18 If you call from somewhere other than the US or Canada, you must choose the software or hardware option when calling for assistance. Choose the software option if you are uncertain if the problem involves the Storwize V7000 Unified software or hardware. Choose the hardware option only if you are certain the problem solely involves the Storwize V7000 Unified hardware.
  • Page 19 At times, you might need expert advice about using a function provided by the system or about how to configure the system. Purchasing the IBM Support Line offering gives you access to this professional advice while deploying your system, and in the future.
  • Page 20 IBM Storwize V7000 Unified: Model 2073-720 Quick Installation Guide...
  • Page 21 IP address to ssh to the IBM call home IP addresses (*.ibm.com) on the internet. IBM Storwize V7000 Unified Information Center The most current information for Storwize V7000 Unified is available in the IBM Storwize V7000 Unified Information Center at publib.boulder.ibm.com/infocenter/ storwize/unified_ic/index.jsp.
  • Page 22 __ v License information __ v License Function authorization document __ v IBM Storwize V7000 Unified Quick Installation Guide __ v Storwize V7000 Unified Problem Determination Guide __ v One USB flash drive, also known as a flash drive, is located with the publications.
  • Page 23 __ – Cable management arm assembly Note: The rail kits for the servers differ from the control enclosure. __ v Two power cords Additional components for file modules: __ v Read first flyer __ v Quality hotline flyer __ v Environmental notices CD __ v Environmental flyers __ v Safety notices __ v Limited warranty information...
  • Page 24 Figure 4 on page 5 shows the rear view of a model 2076-112 or a model 2076-124 control enclosure and identifies the location of the ports. IBM Storwize V7000 Unified: Model 2073-720 Quick Installation Guide...
  • Page 25 Figure 4. This figure shows the data ports in the rear of the control enclosure. 1 Fibre Channel ports. Each canister has four Fibre Channel ports. They are in a block of four in two rows of two connectors. The ports are numbered 1 - 4 from left to right, top to bottom.
  • Page 26 3 , and the lower canister is canister 4 . Canister 3 is top side up, and canister 4 is inverted, or top side down. Figure 7 on page 7 shows the rear view of an expansion enclosure and identifies the SAS port locations. IBM Storwize V7000 Unified: Model 2073-720 Quick Installation Guide...
  • Page 27 Each enclosure takes up the full 2U height in the rack. See the Storwize V7000 Unified Problem Determination Guide PDF on the CD for the full descriptions of the hardware components. Storwize V7000 Unified Storwize V7000 Unified Figure 8. Front view of 2073-720 file module...
  • Page 28 8 Ethernet port 2 (connected to the other file module) 9 Ethernet port 7 10 Ethernet port 3 11 Ethernet port 4 12 Systems-management Ethernet port (NOT USED) 13 Video port IBM Storwize V7000 Unified: Model 2073-720 Quick Installation Guide...
  • Page 29 If you have not done the environmental planning for your system, see the Storwize V7000 Unified physical installation planning topic in the Storwize V7000 Unified Information Center. You must use a supported web browser. Verify that you are using a supported web browser from the following website: http://publib.boulder.ibm.com/infocenter/storwize/unified_ic/topic/...
  • Page 30 If you are adding an expansion enclosure to an existing system, you do not need to power off the system. You can add an expansion enclosure while the system is operational. IBM Storwize V7000 Unified: Model 2073-720 Quick Installation Guide...
  • Page 31: Table Of Contents

    File Module File Module Expansion Enclosure 8 Expansion Enclosure 6 Expansion Enclosure 4 Expansion Enclosure 2 Control Enclosure Expansion Enclosure 1 Expansion Enclosure 3 Expansion Enclosure 5 Expansion Enclosure 7 Expansion Enclosure 9 Figure 11. Recommended rack locations File modules: v Install both file modules in adjacent slots, near the control enclosure.
  • Page 32 A reliable way to check that an IP address is not already in use is to logon to a machine that is in the same subnet as the Storwize V7000 Unified system will use for management communications. Then ping the new IP addresses. For example, ping each of the IP addresses that you intend to use in the InitTool.exe.
  • Page 33 About this task The information in Table 5 on page 14 is required before initializing your system. Fill in all the information needed in the Value column before starting the initial setup of your system using the Initialization tool (InitTool.exe). You should also fill in all of the information needed in “Information required before starting initial configuration of your system”...
  • Page 34 EE Fibre Channel direct connection from file modules to node canisters Note: You cannot use VLAN-based subnets to configure the system network. To configure the Storwize V7000 Unified management IP address, file module 1 and 2 IP addresses, subnet mask, and gateway address, you must provide non-VLAN based network information.
  • Page 35 (such as 123.123.123.1) Storwize V7000 Unified Management IP address for the management IP address Storwize V7000 Unified system. This gives access to the management GUI and CLI running on which ever file module is currently the active management node (such as 123.123.123.10)
  • Page 36 GUI. Your chances of completing the initial configuration successfully are greatly increased if you have carefully planed and completed these tables before you start the initial setup and initial configuration of the system. IBM Storwize V7000 Unified: Model 2073-720 Quick Installation Guide...
  • Page 37 Field Value Notes System name The name of the Storwize V7000 Unified system. It is best if this is also the IP name for the management IP address (For example : myfilesystem1) NetBIOS name Name used for NetBIOS access to the system.
  • Page 38 Email server IP The IP address of your email server for outgoing mail address (for example, 123.123.123.104) Table 7. Information that the system provides to IBM Remote Technical Support Field Value Note Company Name The name of your company...
  • Page 39 IP addresses. Note that call home from one of the storage enclosures is done using email. Table 8. Required information Host Name IP Address Port Description eccgw01.boulder.ibm.com 207.25.252.197 ECC transaction gateway eccgw02.rochester.ibm.com 129.42.160.51 ECC transaction gateway ftp.ecurep.ibm.com 192.109.81.7...
  • Page 40 The Storwize V7000 Unified systems require one, and only one, authentication system to allow network users to access file systems or file sets exported (shared) by the Storwize V7000 Unified system. The authentication system may also be used to provide User ID mapping. Several authentication methods are supported.
  • Page 41 While external user ID mapping is preferred, internal mapping can be done using a table local to the Storwize V7000 Unified system to map Windows user and group objects to arbitrary Unix UIDs and GIDs. That table is not accessible externally, even to another Storwize V7000 Unified system for asynchronous file system replication.
  • Page 42 The following user ID and the password are used to authenticate to the Active Directory server. Active Directory This is the password that must be provided Password when communicating with the remote Active Directory server. IBM Storwize V7000 Unified: Model 2073-720 Quick Installation Guide...
  • Page 43 Table 11. Active Directory configuration information (continued) Field Value Note SFU DOMAIN NAME If you checked Services For Unix (SFU) in the Options field of Table 10 on page 22, then you must complete this field. If you did not check SFU, leave this field blank.
  • Page 44 Table 10 on page 22, then you must complete this field. If you did not check Kerberos, leave this field blank. This field is the file name for the Kerberos KeyTab file. IBM Storwize V7000 Unified: Model 2073-720 Quick Installation Guide...
  • Page 45 Table 13. NIS configuration information Field Value Note NIS MODE [ ] Basic - NIS is used (to provide NFS NIS is typically used for one of the following NetGroup support) in an environment purposes: without Active Directory, LDAP, or v NIS can be used to provide NFS Netgroup Samba Primary Domain Controller support in an environment without Active...
  • Page 46 To specify rules for multiple Active Directory or PDC domains, separate the rules with a semicolon. Example: ad_domain1:DENY_ACCESS; ad_domain2:AUTO; ad_domain3:DEFAULT:ad_domain3\guest NIS DOMAIN This field must be used to specify the NIS Domain that is stored in the registry. IBM Storwize V7000 Unified: Model 2073-720 Quick Installation Guide...
  • Page 47 Table 13. NIS configuration information (continued) Field Value Note Use Id Map [ ] Use ID Map - NIS is used to map If the NIS Mode is Basic, leave this field blank. UNIX IDs to Windows IDs for an If you checked NIS - NFS NetGroup support environment where Active Directory or without User ID Mapping in the Options field...
  • Page 48 IBM Storwize V7000 Unified: Model 2073-720 Quick Installation Guide...
  • Page 49 – Minimum depth of 70 mm (2.76 inch) between the front mounting flange and inside of the front door. – Minimum depth of 157 mm (6.18 inch) between the rear mounting flange and inside of the rear door. © Copyright IBM Corp. 2013...
  • Page 50 2. Working at the front of the rack cabinet, identify the two standard rack units of space in the rack into which you want to install the support rails. Figure 14 on page 31 shows two rack units with the front mounting holes identified. IBM Storwize V7000 Unified: Model 2073-720 Quick Installation Guide...
  • Page 51 2 Units Figure 14. Hole locations in the front of the rack 1 Bottom rail location pin hole 2 Enclosure mounting screw hole. Do not insert the screw until the enclosure is installed. 3 Rack mounting screw hole 4 Top rail location pin hole 3.
  • Page 52 About this task CAUTION: The weight of this part or unit is between 18 and 32 kg (39.7 and 70.5 lb). It takes two persons to safely lift this part or unit. (C009) IBM Storwize V7000 Unified: Model 2073-720 Quick Installation Guide...
  • Page 53 DANGER Observe the following precautions when working on or around your IT rack system: v Heavy equipment–personal injury or equipment damage might result if mishandled. v Always lower the leveling pads on the rack cabinet. v Always install stabilizer brackets on the rack cabinet. v To avoid hazardous conditions due to uneven mechanical loading, always install the heaviest devices in the bottom of the rack cabinet.
  • Page 54 Do not have more than one enclosure extended out of the rack at the same time to avoid the danger of the rack toppling over. 4. Insert a screw into the hole behind each enclosure end cap and tighten the screw. IBM Storwize V7000 Unified: Model 2073-720 Quick Installation Guide...
  • Page 55 Figure 17. Securing an enclosure to a rack cabinet 5. After matching each end cap's serial number to the serial number found on the rear of each enclosure, push the end caps back into position. 6. Repeat this procedure for each additional enclosure that you install. Step 8.
  • Page 56 Cable management Cable management support arm arm assembly Large cable Cable ties or tie or hook hook and and loop strap hook fasteners Figure 18. Cable management arm box contents. IBM Storwize V7000 Unified: Model 2073-720 Quick Installation Guide...
  • Page 57 Friction rail (left) Friction rail (right) M6 screws Front of rails Figure 19. Friction rail box contents. If the slide rails in your rack installation kit came with shipping thumbscrews, remove them before you begin the following installation procedure. Follow these installation instructions: 1.
  • Page 58 4. Push the blue button to allow the latch to slide forward. Then pull the slide rail forward and locate the front latch in the appropriate unit space in front of the rack EIA rail. Adjust the length of the rail. IBM Storwize V7000 Unified: Model 2073-720 Quick Installation Guide...
  • Page 59 Figure 23. Install the front end of the slide rails. 5. Press the blue button to release the bracket. Push the front latch in all the way. Make sure the latch is fully engaged. Repeat steps 1 through 5 to install the other rail into the rack.
  • Page 60 Figure 26. Slide the file module into the rack. 3. Insert both ends of the cable management support arm to the slide rail. IBM Storwize V7000 Unified: Model 2073-720 Quick Installation Guide...
  • Page 61 Figure 27. Install the cable management support arm. It can be installed on either side (left or right). The graphic shows the rear of the rack. Note: Make sure the arm with junctions is facing the file module. Place the cable management arm on the support arm. Pull out both cable management arm pins and then slide the cable management arm tabs into the slots on both inside and outside of the slide rail.
  • Page 62 Figure 30. Connect and route the cables. 7. Insert the M6 screws to the rear of the slides. Use a cable tie to secure the free end of the cable management arm to the rack, if needed. IBM Storwize V7000 Unified: Model 2073-720 Quick Installation Guide...
  • Page 63: Expansion Enclosure

    Figure 31. Secure the cable management arm and the file module in the rack for shipping if needed. 8. Slide the file module into the rack until it snaps into place. To slide the file module out of the rack, press on the release latches 1 . Note: When you move the rack cabinet, or if you install the rack cabinet in a vibration-prone area, insert the M6 screws 2 in the front of the file module.
  • Page 64: Expansion Enclosure

    2, 4, 6. This unit consists of two canisters; the upper and the lower. The lower canister is position upside down. See Figure 33 on page 45 for detailed port locations. IBM Storwize V7000 Unified: Model 2073-720 Quick Installation Guide...
  • Page 65: Expansion Enclosure

    CAUTIO N CAUT I O N Disconnect all Disconnect all supply power for supply power for complete isolation complete isolation CAUTIO N CAUT I O N CAUTIO N CAUT I O N Disconnect all Disconnect all Disconnect all Disconnect all supply power for supply power for supply power for...
  • Page 66: Expansion Enclosure

    3. Attach the SAS cables from the control enclosure to the second expansion enclosure as shown in Figure 35 on page 47. The second expansion enclosure is above the control enclosure. IBM Storwize V7000 Unified: Model 2073-720 Quick Installation Guide...
  • Page 67: Expansion Enclosure

    Expansion enclosure 2 Control enclosure Expansion enclosure 1 Figure 35. Adding a second expansion enclosure a. Port 2 5 of the upper canister, control enclosure, attaches to Port 1 6 of the upper canister, expansion enclosure 2. b. Port 2 7 of the lower canister, control enclosure, attaches to Port 1 8 of the lower canister, expansion enclosure 2.
  • Page 68: Expansion Enclosure

    6. Verify your cabling. Step 11. Attaching the Ethernet cables Attach the Ethernet cables to the control enclosures and file modules. IBM Storwize V7000 Unified: Model 2073-720 Quick Installation Guide...
  • Page 69: File Modules

    This task assumes that your initial planning has determined where the Ethernet cables are to be located. The Storwize V7000 Unified control enclosure requires at least one and a maximum of two 1 Gbps Ethernet connections to each node canister.
  • Page 70: File Modules

    Ethernet port 3 10 GbE external Optional iSCSI on a 2076-312 or network 2076-324 connection 2 (Figure 38) Ethernet port 4 10 GbE external Optional iSCSI on a 2076-312 or network 2076-324 connection IBM Storwize V7000 Unified: Model 2073-720 Quick Installation Guide...
  • Page 71 Figure 39. File module Ethernet connections. Table 17. Ethernet connections available with the file modules IP address is assigned Item Port by InitTool Ethernet port 7 Connect to a switch for public file access Ethernet port 8 Connect to a switch for public file access Ethernet port 9 Connect to a switch for...
  • Page 72 If you encounter that situation, change the service IP addresses on the new nodes before connecting the Ethernet cables. For details, see Figure 39 on page 51 or see the Storwize V7000 Unified Problem Determination Guide PDF on the DVD for further information about setting service IP addresses using a USB flash drive.
  • Page 73 Route the Fibre Channel cables through the Cable Management Arms. Note: Fibre Channel cables are provided by IBM with the file modules. v Repeat the previous step for the other file module.
  • Page 74 8 Lower node canister - Fibre Channel port 2 Note: If you want this control enclosure to communicate with other Storwize V7000 control enclosures, storage controllers, the Storwize V7000 Unified or block hosts, then connect the Fibre cables from your Fibre Channel switch to the remaining node canisters Fibre Channel ports 3 and 4.
  • Page 75 Figure 41. Unlocking the cable retention bracket 3. Slide the cable retention bracket away from the power supply unit until there is enough room to attach the cable retention bracket to the cable. When sliding the bracket away from the cable plug-in, pull the lever on the bracket that controls the cable tie slightly towards the center of the canister.
  • Page 76 Attention: Do not operate the system when the drive assemblies are missing. Drive assemblies that are missing disrupt the airflow; the drives do not receive sufficient cooling. You must insert blank carriers into unused drive bays. IBM Storwize V7000 Unified: Model 2073-720 Quick Installation Guide...
  • Page 77 2. Use the information in Table 19 on page 58 to verify the state of the light emitting diodes (LEDs) on the system. Verify that no faults are detected. See the Storwize V7000 Unified Problem Determination Guide PDF on the CD if problems are encountered.
  • Page 78 LED is off. locations are inverted for ac power failure LED is off. power supply unit 2, which is the right power supply. Powering on a control enclosure: IBM Storwize V7000 Unified: Model 2073-720 Quick Installation Guide...
  • Page 79 1. Power on the control enclosure, if it is not already powered on and configured. Use the power switch on each of the two power supply units, located in the back of the enclosure. 2. Use Table 20 to verify the state of the LEDs on the system. Verify that no faults are detected.
  • Page 80 LED is on or flashing. Attention: Do not go to the next section until the LEDs are in the required states. If any error lights are displayed, see the Storwize V7000 Unified Problem Determination Guide documentation CD for more information about light path issues.
  • Page 81 When the file module is connected to a power source but is not turned on, the operating system does not run, and all core logic except for the integrated management module is shut down. However, the file module can respond to requests from the integrated management module, such as a remote request to turn on the file module.
  • Page 82 IBM Storwize V7000 Unified: Model 2073-720 Quick Installation Guide...
  • Page 83: Chapter 1. Before You Begin The Installation

    Before you begin, make sure you have worked through Chapter 1, “Before you begin the installation,” on page 1 and that your system is properly cabled for the Storwize V7000 Unified system and any expansion enclosures. Refer to the cabling sections listed under Chapter 2, “Performing the hardware installation,” on page 29.
  • Page 84 Note: If you are running a non-Windows operating system, skip to 4. 3. Select the Initialize a new Storwize V7000 Unified option from the Welcome panel of the initialization tool. Click Next. Use the initialization tool to complete the following steps: Note: See 4 for details on IP addresses that are used in these steps.
  • Page 85 The configuration files that the control enclosure and the initialization tool put onto the USB flash drive are used by the file module to set up the management communication paths in the Storwize V7000 Unified system. Chapter 3. Configuring the system...
  • Page 86 This should only take a few minutes, but it might take more than one hour if the Storwize V7000 Unified software level is older than 1.3.2. 4. Insert the USB flash drive into a Windows PC and run the initialization tool executable program that is on the USB flash drive.
  • Page 87 5. Review the hardware image and verify that it reflects your configuration. Refer to the on-screen instructions and take the recommended actions if necessary. (If there is a red X on the left then click on it to show the error information.) Hover over any red cable or LED to see more information.
  • Page 88 IBM Tivoli Assist On-Site (AOS) is a lightweight remote support program intended primarily for help desks and support engineers to diagnose and fix problems without the need of any external dependencies. Assist On-Site is based on the IBM Tivoli Remote Control technology.
  • Page 89 3. Click the Edit button at the bottom. 4. Click Enable Assist on Site (AOS) 5. Select either Lights On or Lights Out. For Storwize V7000 Unified it is recommend to select Lights Out. Lights On establishes a connection through...
  • Page 90 The Storwize V7000 control enclosure has the ability send an inventory information email to IBM at regular intervals. Refer to Setting up email event notifications and inventory reports using the CLI for how to set up inventory reporting.
  • Page 91 Industry-standard devices, ports, and connectors. v You can attach alternative input and output devices. The Storwize V7000 Unified Information Center and its related publications are accessibility-enabled. The accessibility features of the Information Center are described in Viewing information in the information center in the Information Center.
  • Page 92 IBM Storwize V7000 Unified: Model 2073-720 Quick Installation Guide...
  • Page 93 Web sites. The materials at those Web sites are not part of the materials for this IBM product and use of those Web sites is at your own risk.
  • Page 94 IBM may use or distribute any of the information you supply in any way it believes appropriate without incurring any obligation to you. Licensees of this program who wish to have information about it for the purpose of enabling: (i) the exchange of information between independently created...
  • Page 95: Electronic Emission Notices

    IBM, therefore, cannot guarantee or imply reliability, serviceability, or function of these programs. The sample programs are provided "AS IS", without warranty of any kind. IBM shall not be liable for any damages arising out of your use of the sample programs.
  • Page 96: Industry Canada Compliance Statement

    Member States relating to electromagnetic compatibility. IBM cannot accept responsibility for any failure to satisfy the protection requirements resulting from a non-recommended modification of the product, including the fitting of non-IBM option cards. Attention: This is an EN 55022 Class A product. In a domestic environment this product might cause radio interference in which case the user might be required to take adequate measures.
  • Page 97 Klasse A ein. Um dieses sicherzustellen, sind die Geräte wie in den Handbüchern beschrieben zu installieren und zu betreiben. Des Weiteren dürfen auch nur von der IBM empfohlene Kabel angeschlossen werden. IBM übernimmt keine Verantwortung für die Einhaltung der Schutzanforderungen, wenn das Produkt ohne Zustimmung der IBM verändert bzw.
  • Page 98: Taiwan Class A Compliance Statement

    Japan Electronics and Information Technology Industries Association Statement This explains the Japan Electronics and Information Technology Industries Association (JEITA) statement for less than or equal to 20 A per phase. IBM Storwize V7000 Unified: Model 2073-720 Quick Installation Guide...
  • Page 99 This explains the JEITA statement for greater than 20 A per phase. Korean Communications Commission Class A Statement This explains the Korean Communications Commission (KCC) statement. Russia Electromagnetic Interference Class A Statement This statement explains the Russia Electromagnetic Interference (EMI) statement. Notices...
  • Page 100 IBM Storwize V7000 Unified: Model 2073-720 Quick Installation Guide...
  • Page 102 Part Number: 00AR284 Printed in USA GC27-5945-01...