IBM Storwize V7000 Unified Problem Determination Manual page 162

Table of Contents

Advertisement

8. Reconnect the external cables; then, reconnect the power cords and turn on the
Removing a memory module
The following procedure is for a Tier 1 customer replaceable unit (CRU).
Replacement of Tier 1 CRUs is your responsibility. If IBM installs a Tier 1 CRU at
your request, you will be charged for the installation. Service agreements can be
purchased so that you can ask IBM to replace these units.
About this task
Note: Before running a procedure, refer to "Removing a file module to perform a
maintenance action" on page 55.
To remove a DIMM, complete the following procedure.
DIMM
Procedure
1. To help you work safely with Storwize V7000 Unified file module, read the
2. Turn off the file module and peripheral devices, then label and disconnect both
3. Press down on the left and right side latches and pull the server out of the rack
4. Remove the cover, as described in "Removing the cover" on page 87.
5. If riser-card assembly 1 contains one or more adapters, remove it (see
6. Remove the DIMM air baffle, as described in "Removing the DIMM air baffle"
7. Open the retaining clip on each end of the DIMM connector and lift the DIMM
138
Storwize V7000 Unified: Problem Determination Guide Version
peripheral devices and the file module.
Note: You must wait approximately 2.5 minutes after you connect the power
cord of the file module to an electrical outlet before the power-control button
becomes active.
safety information in "Safety" on page xi, "Safety statements" on page xiii, and
"Installation guidelines" on page 58.
power cords and all external cables.
enclosure until both slide rails lock.
"Removing a PCI riser-card assembly" on page 105).
on page 98.
from the connector.
Retaining
clip