Oscillation
13.1 Asynchronous oscillation (OS, OSP1, OSP2, OST1, OST2, OSCTRL, OSNSC, OSE, OSB)
Meaning
<axis>
OS
OSP1
OSP2
OST1
OST2
FA
OSCTRL
556
Name of oscillating axis
Activate/deactivate oscillation
Value:
1
Switch oscillation on
0
Switch oscillation off
Define position of reversal point 1
Define position of reversal point 2
Note:
If incremental movement is active, the position will be calculated incrementally to
the last corresponding reversal position programmed in the NC program.
Define stopping time in reversal point 1 in [s]
Define stopping time in reversal point 2 in [s]
:
-2Interpolation continues without wait for exact stop
<value>
-1Wait for exact stop coarse
0Wait for exact stop fine
>0Wait for exact stop fine and then wait for specified stopping
time
Note:
The unit for the stopping time is identical to that of the
stopping time programmed with
Define feedrate
The feedrate is the defined feedrate of the positioning axis. If no feedrate is
defined, the value stored in the machine data applies.
Specify setting and reset options
Option values 0 to 3 encrypt the behavior at the reversal points on deactivation.
One of the variants from 0 to 3 can be selected. The remaining settings can be
combined at will with the selected variant. Multiple options are appended with
plus characters (+).
:
0
Stop at next reversal point on deactivation of oscillation
<value>
(default)
Note:
Only possible if values 1 and 2 are reset.
1
When the oscillation is deactivated, stop at reversal point 1
2
When the oscillation is deactivated, stop at reversal point 2
3
When the oscillation is deactivated, do not approach reversal
point if no spark-out strokes are programmed
4
Approach end position after spark-out
8
If oscillation is canceled by deletion of distance-to-go,
sparking-out strokes will then need to be executed and the
end position approached if necessary.
16
If oscillation is canceled by deletion of distance-to-go, the
corresponding reversal point will need to be approached as is
the case with shutdown.
.
G4