Komatsu Galeo PC800-8 Shop Manual page 401

Hydraulic excavator
Table of Contents

Advertisement

30 Testing and adjusting
a Action codes and instructions given to operator
Action
Failure mode
code
E03
Error in swing brake system
Error in pump control system
E07
(Emergency escape system is in
operation)
Error in engine controller power
supply system
E10
Abnormality in engine controller
drive system circuit (engine stop)
Error in engine controller system
E11
(Engine protection output down)
E14
Error is throttle system
Error in engine sensor
E15
(coolant temperature, fuel temper-
ature and oil pressure)
E0E
Error in network
PC800, 850-8
Instructions given to operator
Set the swing holding brake release switch to the upper (release) position to
release the brake. When applying the swing brake, use the swing lock switch.
The error may not be reset, depending on the cause of the failure.
In any case, have the machine inspected immediately.
There is abnormality in electronically controlled pump system.
Emergency escape system is in operation and machine performance is par-
tially lost.
Machine can operate normally. Have it inspected immediately, however.
Have the machine inspected immediately.
Set the machine in a safe position and have the machine inspected immediately.
Set the machine in a safe position and have the machine inspected immediately.
Ordinary operation is possible. Have the machine inspected immediately,
however.
Set the machine in a safe position and have the machine inspected immediately.
SEN00913-02