Komatsu Galeo PC800-8 Shop Manual page 258

Hydraulic excavator
Table of Contents

Advertisement

SEN00386-03
2.
Electronic OLSS function
Pump control system
Interconnected control of all pumps is carried out
by one TVC valve.
P mode: Total horsepower control by sensing
engine speed
E mode: Total horsepower control by sensing
engine speed
Emergency pump drive circuit: Constant delivery
control
The pump controller calculates each pump pres-
sure and each J/S differential pressure and
sends the capacity command value to the EPC
valve of each pump to control the delivery of
each pump.
16