Komatsu Galeo PC800-8 Shop Manual page 289

Hydraulic excavator
Table of Contents

Advertisement

10 Structure, function and maintenance standard
Input and output signals
CN1
Pin
Signal name
No.
1
Key switch (Battery)
2
Key switch (Battery)
3
Washer motor output
4
Key switch (Terminal C)
5
Wiper contact W (Lower wiper contact P)
6
GND
7
GND
8
VB + (24 V)
9
Wiper motor (+) <Upper wiper motor (+)>
10 Wiper motor (–) <Lower wiper motor (–)>
11 NC
12 Wiper contact P (Upper wiper contact P)
CN2
Pin
Signal name
No.
1
NC
2
Fuel
3
Radiator coolant level
4
NC
5
Air cleaner clogging sensor
6
NC
7
NC
8
Engine oil level sensor
9
Network (S-NET signal)
10 Network (S-NET signal)
11 Charge level
12 Hydraulic oil temperature (Analog)
13 GND (For analog signal)
14 Personal code relay (Lo)
Window limit switch <Lower wiper
15
switch>
16 Buzzer cancel
17 Swing lock
18 Preheating
19 Light switch
20 Network (S-NET GND)
PC800, 850-8
CN3
Input/
Pin
output
No.
Input
1
NC
Input
2
NC
Output
3
NC
Input
4
NC
Input
5
NC
6
NC
7
NC
Input
8
NC
Output
9
NC
Output
Input
10 NC
Input
11 NC
12 NC
13 NC
14 CAN (Shield)
Input/
output
15 CAN (+)
Input
16 CAN (–)
Input
Input
Input
Input
Input
Input
Input
Input/
output
Input/
output
Input
Input
Input
Input
Input
Input
Input
Input
SEN00386-03
Signal name
Input/
output
Input
Input
Input
Input
Input
Input
Input
Input
Input/
output
Input/
output
Input
Input
Input
Input
Input
47